Honeywell fire smoke damper actuator

    • [DOC File]9459a8a7c04856c345d2 …

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_36eb1d.html

      Damper shall include adjustable damper travel from 25% to 100% (full open). Damper shall include single or dual blade, gear driven dampers and actuator motor. Actuator shall be direct coupled to damper gear. No linkage arms or control rods shall be acceptable. Damper will admit up to 100% outdoor air for applicable rooftop units.

      honeywell damper actuator motor


    • [DOC File]Fast Acting Two Position Actuators (Fire & Smoke) (ML4115 ...

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_b438fd.html

      Fire/smoke damper actuators shall be direct connected (no linkages) two-position spring return types with stroke for 90 degree nominal rotation applications and designed for 30,000 full stroke cycles and normal operation between 0 and 130 F. Actuators control shall be compatible with internal SPST control switch and with torque ratings of 175 lb-in. Actuator timing shall be 15 …

      honeywell damper motor


    • [DOCX File]SECTION 15990

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_fb3191.html

      Include damper position switch linked directly to damper blade to provide capability of remotely indicating damper blade position. Firestat and position indicator switches to be capable of interfacing electrically with building fire alarm system or automation system.

      honeywell m847d1004 damper


    • [DOC File]Fast Acting Two Position Actuators (Fire & Smoke) (ML4115 ...

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_51fe65.html

      Fire/smoke damper actuators shall be direct connected (no linkages) two-position spring return types with stroke for 90 degree nominal rotation applications and designed for 60,000 full stroke cycles and normal operation between 0 and 130 F. Actuators control shall be compatible with SPST control switch and with torque ratings of 30 lb-in. Actuator timing shall be 25 seconds …

      honeywell h2000b actuators


    • HONEYWELL - Fire Dampers, Volume Dampers, Smoke …

      5. Perform trial run of damper & actuator assembly, before attaching other end of duct work to damper. OTHER DAMPER PRODUCTS. Volume Control Dampers: High Performance Volume Damper, Smoke Spill Damper, Min/Max Damper, Face & Bypass Damper, Zone Damper, Non-Return & Barometric Damper. Fire Dampers:

      honeywell actuators 24v


    • [DOCX File]15973b

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_91c900.html

      Duct Smoke Detector and Fire Alarm Interface Modules ... Invensys VB7200 Series, Johnson Controls VG7000 Series, Belimo G200 and G300 Series, and Honeywell V5011/V5013 Series. Minimum size for globe valves shall be 0.7 Cv. ... End switches shall be adjusted to prove the damper the position opposite the fail position of the damper actuator ...

      fire damper actuator motor


    • [DOC File]Power Flame Incorporated

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_37935b.html

      3. For FM or IRI Modulation. Pre-purge operation of the modulating motor shall provide electrical interlock at the 60% air flow position of the burner damper and electrical interlock at the damper low fire start position before the ignition sequence can begin. 4. (If automatic outside fresh air intake louvers are specified).

      dampers and actuators


    • HONEYWELL - Fire Dampers, Volume Dampers, Smoke …

      5. Perform trial run of damper & actuator assembly, before attaching other end of duct work to damper. Note: Do not fit damper near discharge or other turbulent areas. OTHER DAMPER PRODUCTS. Volume Control Dampers: Low & Ultra Low Volume Control, Smoke Spill Damper, Min/Max Damper, Face & Bypass Damper, Zone Damper, Non-Return & Barometric Damper

      honeywell fire damper actuator motor


    • [DOCX File]23 0901

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_83be2a.html

      For instances where the damper actuator cannot be mounted to the jackshaft or other coupling device, damper actuators shall be provided for each damper section. Calibrate position feedback potentiometers, where specified, with range and gain factors as required for proper operation per manufacturer's recommendations.

      honeywell damper actuator motor


    • [DOC File]Guide Specifications 48HC High Efficiency Gas Heat ...

      https://info.5y1.org/honeywell-fire-smoke-damper-actuator_1_a05771.html

      b. Damper shall include adjustable damper travel from 25% to 100% (full open). c. Damper shall include single or dual blade, gear driven dampers and actuator motor. d. Actuator shall be direct coupled to damper gear. No linkage arms or control rods shall be acceptable. e. Damper will admit up to 100% outdoor air for applicable rooftop units. f.

      honeywell damper motor