[DOCX File]Section 09800 - ACOUSTICAL TREATMENT
https://info.5y1.org/kg-m-3-to-pcf_1_1ca42d.html
Thickness: 3/4 inch (19 mm). Density: 26-28 pcf (416-448 kg/cu. m) tested in accordance with ASTM C 209. Tensile Strength: When tested in accordance with ASTM C 209:
[DOC File]23 07 13 - Duct Insulation - SoftR® Duct Wrap FRK-PSK
https://info.5y1.org/kg-m-3-to-pcf_1_259eb9.html
Type 75: 0.75 lb./cu.ft. (12 kg/m3) density: 1-1/2 in, 2 in, 2.2 in or 3 in (38mm, 51mm, 56mm or 76mm) thick The duct wrap insulation shall consist of a blanket of glass fibers factory-laminated to a foil reinforced kraft (FRK) or white poly scrim kraft (PSK) vapor retarder facing with a 2 in (50mm) (min.) stapling and taping flange on one edge.
[DOCX File]GravityStone MSE Specifications
https://info.5y1.org/kg-m-3-to-pcf_1_5c9aee.html
Medium Weight: 105 pcf (1682 kg/m3) to less than 125 psf (2002 kg/m3) Normal Weight: 125 pcf (2002 kg/m3) or more. 3000 psi (20.7 kN/m3) 2500 psi (17.2 kN/m3) 18 pcf (288 kg/m3) 15 pcf (240 kg/m3) 13 pcf (208 kg/m3) Valley Stone units shall meet the following constructability and geometric requirements:
[DOCX File]ARCAT, Inc.
https://info.5y1.org/kg-m-3-to-pcf_1_b9df7e.html
Noise Reduction Coefficient of 3.0 pcf (48 kg/cu m) Density Product: 0.75, when tested on 2 inch (50 mm) samples in accordance with ASTM C 423. Noise Reduction Coefficient of 6.0 pcf (96 kg/cu m) Density Product: 0.60, when tested on 2 inch (50 mm) samples in accordance with ASTM C 423.
[DOC File]SECTION 03540
https://info.5y1.org/kg-m-3-to-pcf_1_67c9d8.html
Compressive Strengths up to: Density Gyp-Crete® 2,200 psi (15.2 MPa) 110 pcf (1,762 kg/m3) Gyp-Crete 2000®/3.2K 3,200 psi (22.1 MPa) 115 pcf (1,842 kg/m3) Dura-Cap® 4,000 psi (27.6 MPa) 115 pcf (1,842 kg/m3) Commercial Topping® 4,500 psi (31.0 MPa) 125 pcf (2,002 kg/m3) Therma-Floor® 3,000 psi (20.7 MPa) 115 pcf (1,842 kg/m3) ...
[DOCX File]ARCAT, Inc.
https://info.5y1.org/kg-m-3-to-pcf_1_33f935.html
SECTION 09 80 00. ACOUSTICAL TREAMENT. Display hidden notes to specifier. (Don't know how? Click Here). Copyright 2005 - 2015 ARCAT, Inc. - All rights reserved
[DOCX File]Section 23 07 11 - HVAC AND PLUMBING INSULATION
https://info.5y1.org/kg-m-3-to-pcf_1_64dbd1.html
Density 48 kg/m3 (3.0 pcf), labeled thickness thermal conductivity (k-value) 0.23 Btu x inches / Hr x sq. ft. x deg. F (0.042 W/m x K) or less at 24 degrees C (75 degrees F), and maximum temperature 93 degrees C (200 degrees F) or greater.
[DOC File]Guide Specification for Acoustical Lining of Sheet Metal Ducts
https://info.5y1.org/kg-m-3-to-pcf_1_80fcfe.html
3. Owens Corning Quiet® Duct Liner Board, for service at internal air velocities not to exceed 6,000 fpm (30.5 m/s): a. 3.0 pcf (48 kg/m3) density, 1-1/2" or 2" (38mm or 51mm) thick. The duct liner shall have a black pigmented mat on the airstream side to resist damage during installation and in service.
[DOCX File]Infinity System - DS136
https://info.5y1.org/kg-m-3-to-pcf_1_3be201.html
The I. S. Insulation Board shall be aged, expanded polystyrene with a nominal density of 1.0 pcf(16 kg/m3) but not less than 0.95 pcf (15 kg/m3) meeting the current published specifications of Dryvit's Publication DS131. N. OTE: The . 0.95 . pcf (15 kg/m. 3)
[DOCX File]Section 23 07 11 - HVAC, PLUMBING, AND BOILER PLANT …
https://info.5y1.org/kg-m-3-to-pcf_1_105201.html
A.ASTM C612 (Board, Block), Class 1 or 2, density 48 kg/m3 (3 pcf), k = 0.037 (0.26) at 24 degrees C (75 degrees F), external insulation for temperatures up to 204 degrees C (400 degrees F) with foil scrim (FSK) facing. SPEC WRITER NOTE: See HVAC Design Manual Chapter 7 for high humidity areas. Specify class B-5 duct insulation for high ...