Labview waveform data
[DOCX File]Wright State University
https://info.5y1.org/labview-waveform-data_1_e7002c.html
LABVIEW HANDOUT 2. CHAPTER 2: THE FOR LOOP AND THE WAVEFORM GRAPH. Open a . Blank VI. Place a . For. Loop. on the . Block Diagram: Functions Palette>>Programming >> Structures>> For. Loop. The initial value of the Loop Iteration Terminal is zero, and increments by one integer each iteration. The Loop Count Terminal resides in the upper left ...
[DOC File]Lab 3: Motor-Pump System Measurements and LabView Interface
https://info.5y1.org/labview-waveform-data_1_fd5e34.html
Turn on the oscilloscope, run the motor at 50 percent and set the scope to display the waveform from the turbine flowmeter and indicate frequency. Run the system at pressure differentials from 0.4 to 1.2 inH20. Use the manometer to set the motor velocity quickly but then read the transducer voltage.
[DOC File]MY LabVIEW
https://info.5y1.org/labview-waveform-data_1_e904d1.html
Bundle two 1D arrays of X and Y data together for each plot. Then build an array of these clusters and wire it to the Waveform Graph indicator. Build an n-dimensional array of data with each plot in a separate row (or column) in the array, then wire the array to the Waveform Graph indicator.
[DOC File]A Simple Frequency Response Program using LabVIEW
https://info.5y1.org/labview-waveform-data_1_5a9d1c.html
The sampling must be buffered for the data to be acquired without timing errors. The thermistor program, in contrast, uses a software-timed acquisition. Buffered data acquisition for a single waveform is accomplished using the LabVIEW VI AI Acquire Waveform.vi. This is found on the functions palette (block diagram), Data Acquisition -> Analog ...
[DOC File]Lab 2: Circuit Simulation
https://info.5y1.org/labview-waveform-data_1_9b90e5.html
LabVIEW! Prelab (25 points) – Due at the beginning of lab. 1. Figure 1 shows a logic circuit. On your data sheet, give the truth table for the circuit. Figure 1: Prelab Logic Circuit. Table 1 a hypothetical logic circuit output. On your data sheet, draw a circuit that would produce the output shown in Table 1 from the inputs shown. Table 1 ...
[DOC File]Open and Run a Virtual Instrument - Boston University
https://info.5y1.org/labview-waveform-data_1_6afff3.html
Select a waveform chart on the Controls»Graph Indicators palette and place it on the front panel. The waveform chart will display the data in real time. Type Value History inside the label and click outside the label or click the Enter button. The waveform chart legend labels the plot Plot 0.
[DOC File]ISE 370: Industrial Automation and Control
https://info.5y1.org/labview-waveform-data_1_c4eba0.html
The Index Waveform Array VI returns. a single waveform cluster. Normally, the waveform cluster contains (3) parts: a data . array (Y), a starting time (t0), & a time between data points (dt). Here, AI Sample. Channels acquires only one data point; therefore, it only outputs a waveform data type. with a data array (Y) & a starting time (t0).
[DOCX File]Amplitude-shift keying (ASK) is a form of modulation that ...
https://info.5y1.org/labview-waveform-data_1_7dc5e3.html
Shift Keying Using Labview. LABVIEW . VIRTUAL EQUIPMENT NEEDED: Signal simulators (3). Case Structure Unit for randomization. Switches. Waveform chart displays. Selector function. Absolute value generator. Level comparator. Low pass Filter. Dynamic data to Scalar data converter. Preamble
[DOC File]Lab 1. Fourier Series & SA
https://info.5y1.org/labview-waveform-data_1_1e7191.html
Print the LabVIEW window containing the effective amplitude spectrum and the time-domain waveform. Part B: Periodic Rectangular Waveforms Set the output signal frequency of the function generator to 1 KHz, and set the amplitude to 2 Volts (the amplitude of the signal should change between -2 V and +2 V).
[DOC File]Open and Run a Virtual Instrument
https://info.5y1.org/labview-waveform-data_1_cc9c9e.html
The waveform chart legend labels the plot Plot 0. Use the Labeling tool to triple-click Plot 0 in the chart legend, type Value, and click outside the label or click the . Enter . button to relabel the legend. The random number generator generates numbers between 0 and 1, in a classroom setting you could replace this with a data acquisition VI.
[DOC File]Implementing LabVIEW for backend processing
https://info.5y1.org/labview-waveform-data_1_5b1b8e.html
In our case, the millisecond multiple is user specified period times 1000. This function is usually used as a While loop timing control to avoid LabVIEW from using too much of the processor. The subVI “Simulated Temperature” sends the data to the slide to be displayed in front panel, as a slide and as a waveform graph.
[DOC File]Re-Introduction to LabVIEW
https://info.5y1.org/labview-waveform-data_1_20be54.html
Figure 7: LabVIEW Diagram Window after completeion of the Step-by-Step Walkthrough. Lab Experiments. Use the same type of setup as in the Step-by-Step walkthrough to make the function generator respond to inputs from LabVIEW. Hint: To make a sinusoidal waveform use the command Sin 1000 5.0 0.
[DOC File]Introduction to LabVIEW
https://info.5y1.org/labview-waveform-data_1_ef02dc.html
LabVIEW Assignment. There are 2 Questions. Q1. Create a VI that produces a sine wave with a specified frequency and displays the data on a Waveform chart until stopped by the user. Solution:-Open a blank VI from the Getting Start Screen. Place a chart on the front panel.
[DOC File]1 - MY LabVIEW
https://info.5y1.org/labview-waveform-data_1_37db22.html
Build an n-dimensional array of data with each plot in a separate row (or column) in the array, then wire the array to the Waveform Graph indicator. C Bundle the elements of each waveform into a cluster and build an array of these clusters, then wire the array to the Waveform Graph indicator. D Both B. and C. E Both A. and C.
[DOC File]Total Dissolved Solids
https://info.5y1.org/labview-waveform-data_1_6ee501.html
Labview VI (insert screen shot) Plotting the data in real time on a chart (insert graph) Incorporating the graphical analysis tools available with the use of a Waveform Graph (insert graph) Modification 1- displaying heart rate. Note: Do not attempt this modification until you have completed the Project Design Requirements.
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.