Lbs per hr to gpm
B Plus suggested spec - Home | AERCO
Each heater shall be rated to heat ____ GPM of water from ___ oF to ___ oF when supplied with ___lbs/hr of saturated steam at ___ PSIG to the control valve. Each heater shall be of the vertical, cross-flow , 2-pass, Semi-Instantaneous design, having service water in the shell and steam in the coils.
[DOC File]Outline Specification
https://info.5y1.org/lbs-per-hr-to-gpm_1_ef819b.html
16. Electrical Electrical Wiring: Type of wiring and load centers, number of circuits per unit, individual unit metering or project metering, space conduit for future load requirements, radio or TV antenna systems: Lighting (Type for various locations): Energy Star labeled: yes no
[DOC File]FORMULA SHEET - Homestead
https://info.5y1.org/lbs-per-hr-to-gpm_1_691754.html
GPM X PSI X .0007 (this is a 'rule-of-thumb' calculation) How many horsepower are needed to drive a 10 gpm pump at 1750 psi? GPM = 10 PSI = 1750 GPM X PSI X .0007 = 10 X 1750 X .0007 = 12.25 horsepower Pump Output Flow (in Gallons Per Minute) RPM X Pump Displacement / 231
Introduction - AZDEQ
PM total ( lbs hr )=TDS mg l × 1 lbs mg 453,600 ×3.785( l gal )× Q circ (gpm)× Q drift 100 ×60( min hr ) Select a TDS concentration (ppm) from the drop-down menu here to find respective percent masses of the given particle sizes at the selected concentration: 3000
[DOC File]Conversion Sheet Page 2
https://info.5y1.org/lbs-per-hr-to-gpm_1_4b811f.html
FILTRATION. Filtration Rate (GPM/sq.ft) = Filter Production (gallons per day) sq. ft. = square feet (Filter area sq. ft.) x (1,440 min/day)
Project Request #: __________________ Title
Utility Demand Demand Consumption (per year) Compressed Air. cfm cfm MCF psig psig Electricity. KVA KVA KWH V V Fuel Oil. gph gph 1,000 gal Chilled Water tons tons ton-hr Natural Gas. cfh cfh MCF Propane gpd gpd gal Sanitary. gpd gpd 1,000 gal Steam pph pph 1,000 lbs psig psig Water (domestic) gpm gpm 1,000 gal Water (fire)
MASTER PAGE - AERCO
Each heater shall be rated to heat ____ GPM of water from ___ °F to ___ °F when supplied with ___lbs/hr of saturated steam at ___ PSIG to the electronic control valve. Design & Construction: Each heater shall be of the vertical, cross-flow, 2-pass, Semi-Instantaneous design, having service water in the shell and steam in the coils.
[DOC File]GENERAL FORMULAS
https://info.5y1.org/lbs-per-hr-to-gpm_1_6865a8.html
Minutes/hr. = 60. TOTAL BTUH = 500 x GPM x (Lvg. Water Temp. – Ent. Water Temp.) Where 500 = lbs./gal. X min./hr. x Specific heat water. Lbs./gal. = 8.33. Minutes/hr. = 60. Specific heat water = 1. SENSIBLE BTUH. SENSIBLE BTUH = 1.08 x SCFM x (Ent. Air DB – Lvg. Air DB) Where 1.08 = (Specific heat of air at 70E) x (Minutes/hr.) x Density ...
[DOC File]Air Performance Test Forms - Operating Data …
https://info.5y1.org/lbs-per-hr-to-gpm_1_e70940.html
gpm = gallons per minute. in. w.c. = inches of water column. lbs. = pounds. MW = megawatts. Psig = pressure per square inch gauge (P = pressure drop . NOTE: This form provides only a summary of the operating conditions during the performance test. Additional and more detailed records are required to meet the requirements of Minn. R. 7017.2035.
[DOC File]Conversion Sheet Page 1 - Home Page | California …
https://info.5y1.org/lbs-per-hr-to-gpm_1_974354.html
1 pound (lb) = 454 grams (gm) 1 lb = 7,000 grains (gr) 1 grain per gallon (gpg) = 17.1 mg/L. 1 gm = 1,000 milligrams (mg) 1 day = 24 hr = 1,440 min = 86,400 sec. 1,000,000 gal/day ÷ 86,400 sec/day ÷ 7.48 gal/cu ft = 1.55 cu ft/sec/MGD. F. low, velocity, area. Q = A x V Quantity = Area x Velocity.