Line length calculator
[PDF File] Thread Length Calculator
http://5y1.org/file/13877/thread-length-calculator.pdf
1. Total length of stitching. 2. Stitch Size (SPI) 3. Thickness of item to be stitched. 4. Hole Count. Let’s look at each of these in more detail. 1. Total length of stitching. If you are stitching in a straight line, it is as simple as putting a rule next to the holes to be stitched and measuring the length, for this example, let’s call ...
[PDF File] Hose Assembly Live Length Calculation Guide - Hose Master
http://5y1.org/file/13877/hose-assembly-live-length-calculation-guide-hose-master.pdf
Length Calculations Example : Constant Radius Traveling Loop (A-Loop) www.hosemaster.com For a hose installed in a constant radius traveling loop (A-Loop), calculate the minimum live length required for 1/2” ... (5.5” for 1/2” AF4750). If movement on one side of the center-line exceeds the movement on the other side of the center-line ...
[PDF File] Determining Leach Field Sizes
http://5y1.org/file/13877/determining-leach-field-sizes.pdf
6. Using the total length of pipes find factors that allows you to neatly divide up the number of straights and perforated pipes. Example: Total Pipe Needed 6m # of Perforated Pipes 2m # of Straight Pipes 3m 7. To find out the number of pipes you would need to buy using equation 5 () Equation 5:Number of Pipes Needed 8.
[PDF File] Refrigerant Piping Design Guide - Daikin Applied
http://5y1.org/file/13877/refrigerant-piping-design-guide-daikin-applied.pdf
How to Determine Equivalent Length Calculate the equivalent length of the liquid line for the following condensing unit with DX air-handling unit. The liquid line is composed of the following elements: • 30 ft (9.14 m) of 1-3/8 inch (35 mm) piping • 4 long radius elbows • 1 filter-drier • 1 sight glass • 1 globe type isolating valve
[PDF File] A Tutorial on Calculating Source Impedance Ratios for …
http://5y1.org/file/13877/a-tutorial-on-calculating-source-impedance-ratios-for.pdf
As stated in the introduction, the length of a line can be defined by physical distance, impedance, or its SIR. The nominal voltage and the short-circuit level of the system have a much greater effect on whether a line is considered short than either the length or impedance of the line. Reference [1] gives an example of a typical 500 kV line
[PDF File] Zin Calculations using the Smith Chart - University of Kansas
http://5y1.org/file/13877/zin-calculations-using-the-smith-chart-university-of-kansas.pdf
For example, say z ′. = 0.6 − j 1.4 . We find on the Smith Chart the circle for r =0.6 and the circle for x =-1.4. The intersection of these two circles is the point on the complex Γ plane corresponding to normalized impedance. ′ = 0.6 − j 1.4. L . This point is a distance of 0.685 units from the origin, and is located at angle of ...
[PDF File] Long Line Applications Guideline R 410A Split Systems
http://5y1.org/file/13877/long-line-applications-guideline-r-410a-split-systems.pdf
The tubing configuration uses four standard 90 elbows and two 90 long−radius elbows. Checking Table 2, the total equivalent length is calculated as: 165 ft straight tubing + (four standard 90 elbows x 2 ft) + (two long−radius 90 elbows x 1.4 ft) = 165 ft.. + 8 ft + 2.8 ft = 175.8 ft total equivalent length.
[PDF File] Guide to Transmission Line Constants Calculations …
http://5y1.org/file/13877/guide-to-transmission-line-constants-calculations.pdf
LINE CONSTANT PROGRAM COMPARISON . The result of the example calculation above can be checked by comparing it to the result from the line constant program. In order to make this comparison, CAPE program was used. In order to run this program, the actual line length should be inserted and this amount is 3.64 miles.
[PDF File] The Critical Length of a Transmission Line
http://5y1.org/file/13877/the-critical-length-of-a-transmission-line.pdf
In Figure 4, we show the measured and simulated impedance looking into the front of a transmission line. Figure 4. The measured impedance of the real, physical transmission line is the circles. The simulated impedance of the ideal, lossless transmission line, with a TD = 0.16 nsec and Z0 = 47 Ohms, is the blue line.
[PDF File] FABRICATING AND USING A PCB-BASED TRL PATTERN WITH …
http://5y1.org/file/13877/fabricating-and-using-a-pcb-based-trl-pattern-with.pdf
An online microstrip line calculator was used to calculate the effective permittivity and line width of the 50 ohm trace at 1193 MHz. Using a quarter wavelength at 1193 MHz will be a good start for choosing a line length. You can perform calculation based on that to get the each line length that goes from 20 to 160 degree when the …
[PDF File] Pipe Sizing Based on the 2015 IFGC and IRC - ICC
http://5y1.org/file/13877/pipe-sizing-based-on-the-2015-ifgc-and-irc-icc.pdf
Second, determine the equivalent length of all fittings and add it to the pipe length to get the total determined length. This is typically done on a piping run having four or more fittings. Many designers simply add 50 percent of the actual length of piping as an all-inclusive fitting allowance (i.e., actual pipe length x 1.50).
[PDF File] Refrigerant Piping Design Guide
http://5y1.org/file/13877/refrigerant-piping-design-guide.pdf
How to Determine Equivalent Length Calculate the equivalent length of the liquid line for the following condensing unit with DX air-handling unit. The liquid line is composed of the following elements: • 30 ft (9.14 m) of 1-3/8 inch (35 mm) piping • 4 long radius elbows • 1 filter-drier • 1 sight glass • 1 globe type isolating valve
[PDF File] The following material was extracted from earlier edi- the 21st …
http://5y1.org/file/13877/the-following-material-was-extracted-from-earlier-edi-the-21st.pdf
in a length of line causes a 3-to-1 SWR ratio to ex-ist. If we temporarily disregard line losses, we may state that the SWR remains constant throughout the entire length of this line. This is represented on the Smith Chart by drawing a 3:1 constant SWR circle (a circle with a radius of 3 on the resistance axis), as in Fig 5. The design of the ...
[PDF File] Analysis and Design of Coupled Line Couplers - University of …
http://5y1.org/file/13877/analysis-and-design-of-coupled-line-couplers-university-of.pdf
A: The electrical length of the coupled transmission lines is also a design parameter. Assuming that we want to maximize the coupling onto port 3 (at design frequency ω 0), we find from the expression above that this is accomplished if we set β 0A such that: cotβ 0A=0 Which occurs when the line length is set to: 0 0 2 4 βAA=⇒=π λ
[PDF File] Department of Public Health Division of Environmental …
http://5y1.org/file/13877/department-of-public-health-division-of-environmental.pdf
Leach lines cannot exceed 100 feet in length. If the system needs more than 100 feet of trench, split the length as evenly as possible between 2 or more leach lines. For example, a system that needs 240 feet of trench should have 3 lines, each 80 feet long. Trench credit is how much area per linear foot of leach line is ‘credited’ line
[PDF File] Using The Restraint Length Calculator v7 - EBAA
http://5y1.org/file/13877/using-the-restraint-length-calculator-v7-ebaa.pdf
The Restrained Length Calculator version (RLC) is a specifically designed calculator application, developed by EBAA Iron, Inc., that provides, in feet, the restrained values required to properly restrain one or more fittings in a pressurized water or wastewater pipeline design.
[PDF File] Transmission Lines - Education Technology | Texas Instruments
http://5y1.org/file/13877/transmission-lines-education-technology-texas-instruments.pdf
coefficient for line lengths of d=0, 1/8, 1/4, and ½ wavelengths. Since the line length is given as a fraction of wavelength, λ=1 (screen 18). (18) Topic 59: Input Impedance/Admittance The equation for input impedance can be defined as a function. The input impedance depends upon the line length. For lines with d=nλ/2, the input impedance
[PDF File] Impedance Calculations - University of New Hampshire
http://5y1.org/file/13877/impedance-calculations-university-of-new-hampshire.pdf
This represents the length of the transmission line, where is the wavelength in the transmission line. The normalized input impedance for that transmission line is read from the Smith Chart to be 1 - j0.75. This is read from the point where the circle you drew intersects the Re{ Z N} = 1 circle. The actual input impedance to the terminated line is
[PDF File] Transmission Line Input Impedance - University of Kansas
http://5y1.org/file/13877/transmission-line-input-impedance-university-of-kansas.pdf
transmission line characteristic impedance, the input impedance will be likewise be equal to Z 0 regardless of the transmission line length A. 4. L L ZjX= If the load is purely reactive (i.e., the resistive component is zero), the input impedance is: Z 0,β A ZL=Z0 in 0 ZZ=
[PDF File] LONG LINE SET TECHNICAL PUBLICATION - Goodman MFG
http://5y1.org/file/13877/long-line-set-technical-publication-goodman-mfg.pdf
8. Maximum linear length of line set is: a. 200 feet (61.0 m) for single stage units with scroll or reciprocating compressors. b. 150 feet (45.7 m) for single stage units with rotary compressors. c. 150 feet (45.7 m) for two stage units. 9. Low voltage wiring. Verify low voltage wire gauge is adequate for the length used due to increased line
[PDF File] Driveshaft Application Guidelines - Spicer Parts
http://5y1.org/file/13877/driveshaft-application-guidelines-spicer-parts.pdf
Step 1 – Calculate the torque capacity requirement for the interaxle driveshaft using the following formula. .&’.3’(Nm) (tandem axle and tridem 1stinteraxle) T = Interaxle driveshaft torque requirement (Nm) T. m= Main driveline application torque …
[PDF File] PowerWorld Transmission Line Parameter Calculator
http://5y1.org/file/13877/powerworld-transmission-line-parameter-calculator.pdf
The PowerWorld Transmission Line Parameter Calculator (TransLineCalc) is a tool designed to compute characteristic line parameters given the type of the conductor and the tower configuration of a three-phase overhead transmission line. The parameters computed are the resistance R, reactance X, susceptance B, and conductance G.
[PDF File] SUCTION & LIQUID LINE SIZING CHARTS USING LINE SIZING …
http://5y1.org/file/13877/suction-liquid-line-sizing-charts-using-line-sizing.pdf
TYLER SPEC GUIDE SUCTION & LIQUID LINE SIZING SUCTION & LIQUID LINE SIZING CHARTS USING LINE SIZING CHARTS Basis These line sizing charts are based on a suction pressure drop equivalent to a 2°F change in saturation pressure and liquid line pressure drop of 5 psi. For R-404A Low Temperature 1 psi; for R-404A and R-22 …
[PDF File] Line Sizing - Hussmann, a Panasonic Company
http://5y1.org/file/13877/line-sizing-hussmann-a-panasonic-company.pdf
Discharge Supply Condenser Line Sizing – Medium Temperature –. A Condenser Line Sizing chart is established for an equivalent pipe run of 100 feet. For longer runs use the following formula: Table Capacity * √100/Longer Length = Longer Line Capacity Condensing Temperature °F Discharge – Maximum Allowable MBH Line.
[PDF File] A Tutorial on Calculating Source Impedance Ratios for …
http://5y1.org/file/13877/a-tutorial-on-calculating-source-impedance-ratios-for.pdf
As stated in the introduction, the length of a line can be defined by physical distance, impedance, or its SIR. The nominal voltage and the short-circuit level of the system have a much greater effect on whether a line is considered short than either the length or impedance of the line. Reference [1] gives an example of a typical 500 kV line
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.