    • [DOC File]Technical Manual, Sec. 3, Ch. 2: Indoor Air Quality ...

      https://info.5y1.org/m3-per-minute-to-cfm_1_a16da1.html

      ASHRAE in its 62-1989 standard recommends 20 cubic feet per minute (CFM) of outdoor air per occupant for offices. For smoking lounges, up to 60 CFM of outdoor air per occupant should be provided. When possible, use local exhaust ventilation and enclosure to capture and remove contaminants generated by specific processes.


    • INDOOR AIR QUALITY ASSESSMENT

      At lower rates of cubic feet per minute (cfm) per occupant of fresh air, carbon dioxide levels would be expected to rise significantly. A ventilation rate of 20 cfm per occupant of fresh air provides optimal air exchange resulting in carbon dioxide levels at or below 800 ppm in the indoor environment in each area measured.


    • Indoor Air Quality Assessment - UMass Medical School ...

      At lower rates of cubic feet per minute (cfm) per occupant of fresh air, carbon dioxide levels would be expected to rise significantly. A ventilation rate of 20 cfm per occupant of fresh air provides optimal air exchange resulting in


    • [DOCX File]Section 15050

      https://info.5y1.org/m3-per-minute-to-cfm_1_a75214.html

      Cubic feet per minute (CFM) Meters cubed per hour (m3/h) Liters per second (l/s) Feet per minute (fpm) Meters per second (m/s) Alarm Muting option, which silences the audible alarm for an adjustable time period when the mute button is pushed. If another alarm is generated during the mute period, the new alarm will override the mute delay and ...


    • [DOCX File]SECTION 25 0910 - LABORATORY AIRFLOW CONTROLS PART …

      https://info.5y1.org/m3-per-minute-to-cfm_1_f5c2db.html

      The device shall be configurable to display one of the following measurement units; cubic feet per minute (CFM), meters cubed per hour (m3/h), liters per second (l/s), feet per minute (FPM), or meters per second (m/s). This device shall have the ability to display system errors caused by airflow or sash travel malfunctions.


    • [DOCX File]Section 23 74 13 - PACKAGED, OUTDOOR, CENTRAL …

      https://info.5y1.org/m3-per-minute-to-cfm_1_030606.html

      Leakage rate shall not exceed 1.6 cubic meters/min/square meter (5 cfm per square foot) at 250 Pa (1 inch water gage) and 2.8 cubic meters/min/square meter (9 cfm per square foot) at 995 Pa (4 inches water gage) // Electronic // Pneumatic // damper operators shall be furnished and mounted in an accessible and easily serviceable location by the ...


    • [DOCX File]Section 23 73 00 - INDOOR CENTRAL-STATION AIR …

      https://info.5y1.org/m3-per-minute-to-cfm_1_d04974.html

      Leakage rate shall not exceed 2.5 cubic meters/minute/square meter (8 CFM per sq. foot) at 250 Pa (1 inch WG). Dampers and operators shall be furnished and factory installed by AHU manufacturer. Damper operators shall be of the same manufacturer as controls furnished under Section 23 09 23, DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC.


    • [DOC File]Exhaust Recirculation Policy

      https://info.5y1.org/m3-per-minute-to-cfm_1_52617c.html

      The air to be recirculated contains process contaminants whose PEL is equal to or exceeds 1,000 parts per million (ppm), or 15 milligrams per cubic meter (mg/m3). 2. The work area in question is ventilated with an exhaust and air supply system which provides an air flow rate of at least one cubic foot of air per minute (cfm) per square foot of ...


    • [DOC File]Vacuum System Overview: Pressure, Mass-Flow and …

      https://info.5y1.org/m3-per-minute-to-cfm_1_087232.html

      A Pa-l/s is 0.001 Pa-m3/s since a liter is 0.001 m3. In addition, the units slm and sccm stand for “Standard Liter per Minute” and “Standard Cubic Centimeter per Minute.” The “standard” used denotes gas at 1 atmosphere pressure (760 Torr or 101,323 Pa) and at 0° Celsius.


    • Assessment of Methane and VOC Emissions from Select Oil ...

      Flow (cfm) = Flow rate of sample and background air in cubic feet per minute The BHFS response is calibrated at 2.5% and 100% CH4 before each day’s trials. As detailed in the results and discussion section, the translation of the BHFS from downstream natural gas inspection applications (where CH4 dominates the emission speciation profile) to ...