Specification Number: 16440-4
2.02 manufacturers: fractional horsepower manual motor controller A. Square D - Class 2510 Type F. Description: NEMA ICS 2, ac general-purpose Class A manually operated, full-voltage controller for fractional horsepower induction motors, with thermal overload unit, [[red] [green] pilot light,] and [key] [toggle] operator.
[DOC File]3270 Operators Manual - Bayliner 32xx.com
https://info.5y1.org/manual-motor-starter-heater_1_5948fb.html
Starter Motor. The engine starter motor is designed to deliver high horsepower for only very short intervals. Avoid operation for more than 15 seconds at one time. Due to its high horsepower this motor builds up considerable heat and can be permanently damaged with prolonged use.
[DOC File]PART 1
https://info.5y1.org/manual-motor-starter-heater_1_1f430a.html
MANUAL MOTOR PROTECTION STARTER. Provide manual starters for all motors less than 1/2 horsepower unless otherwise shown on the drawings. Ensure the starters contain a trip free switch, overload element and pilot light. Individually mounted manual starters when located at the motor, does not require a separate motor disconnect switch.
[DOC File]PSG Section 16481 - Eaton
https://info.5y1.org/manual-motor-starter-heater_1_6186fa.html
MAnual Motor Control. Single-Phase Manual Starters . Manual single-phase starters 1 hp or smaller shall be Cutler-Hammer type MS starters or approved equal. The starter shall have a quick-make/quick-break toggle mechanism. The overload shall have a field adjustment allowing up to +/- 10% variance in ratings of the nominal heater value
[DOC File]Section 26 29 11 - MOTOR STARTERS
https://info.5y1.org/manual-motor-starter-heater_1_6540fa.html
Submit a list of all motors listing motor nameplate rating and heater element installed. D. Motor Data: Provide neatly-typed label inside each motor starter enclosure door identifying motor served, nameplate horsepower, full load amperes, code letter, service factor, voltage/phase rating and heater …
[DOC File]Motor Starters to 600 V
https://info.5y1.org/manual-motor-starter-heater_1_96043c.html
Starter suitable for constant kW type motor and with components as follows: One-3 pole contactor for each winding for separate winding motors. One-3 pole and one-5 pole contactor for each reconnectable winding for consequent pole type motors. Three overload relays with 3 heater elements and manual reset for each speed. Accessories: