      Two-Position Motorized Damper: Damper shall be a 2-position damper. Damper travel shall be from the full closed position to the field adjustable %-open setpoint. Damper shall include adjustable damper travel from 25% to 100% (full open). Damper shall include single or dual blade, gear driven dampers and actuator motor.


    • [DOC File]BMC50610 CC Spec_Rev 0.doc

      https://info.5y1.org/motorized-damper-120v_1_029dfa.html

      EPC SAMPLE SPECIFICATION. Typical of work package by Power Generation Consulting. 01/13/2012 STATEMENT OF WORK AND SPECIFICATIONS Issued for RFP Revision 0


    • [DOC File]Section 15720 - Air Handling Units

      https://info.5y1.org/motorized-damper-120v_1_79eb5c.html

      The motorized damper shall be spring return for closure during unit shutdown or power interruption. ** NOTE TO SPECIFIER ** Delete air section damper type not required. ... Primary to 120v control transformer. 6,000 volt ignition transformer. Control fuse block w/ slow blow fuse.


    • [DOCX File]PART 1 utions.com

      https://info.5y1.org/motorized-damper-120v_1_abfce0.html

      Electrical input to the boiler shall be [120v/1ph (not available on sizes 2500 or 3000), 208v/1ph, 230v/1ph, 208v/3ph, 230v/3ph, 460v/3ph]. The manufacturer will mount the control transformer and fuses inside the boiler control panel. Single-point electrical hook-up for each boiler shall be provided.


    • Quantifying the Energy-Related Costs and Benefits

      Check barometric activation of motorized damper to kitchen exhaust and dryer exhaust *Shaded items were not part of the original NZERTF commissioning activities. ... (hot)-to-ground (expected values are 240 V, 120 V, 0 V and 120V, respectively). Start-up the inverter and confirm normal operation.


    • [DOCX File]SECTION 23 34 23.08 – PROPELLER FANS

      https://info.5y1.org/motorized-damper-120v_1_efa76a.html

      Provide 120V to 24V ac control power transformer in NEMA 1 enclosure. Wall Collar: Provide wall collar to mount propeller wall fan and accessories into wall opening. Furnish wall collar [fully assembled] [as kit, for field assembly].


    • [DOC File]PROPOSAL - Antietam Fire Apparatus, Inc.

      https://info.5y1.org/motorized-damper-120v_1_16c14c.html

      Damper controls shall be pneumatically operated to provide air discharge to the windshield, front overhead air discharge louvers or floor position as required and shall be located above the driver seat position. An electric water valve to control the amount of heat. Fully insulated housing. BTU: 34,000 A/C. BTU: 50,000 Heat. CFM: 410 @ 13.8 volts


    • [DOC File]44 - Municipal Corporation of Delhi

      https://info.5y1.org/motorized-damper-120v_1_ffd982.html

      However, these dampers will be motorized types having electric actuator, actuated by smoke sensor and electronic heat detector factory set at 165 deg. F. The dampers shall be provided with spring return system to ensure damper closing incase of power failure and open the same in case of power being restored.



    • [DOC File]SECTION 235216 - CONDENSING BOILERS - Lochinvar

      https://info.5y1.org/motorized-damper-120v_1_567295.html

      120V / 1PH. Frequency: 60 Hz. VENTING. Some boiler manufacturers offer venting kits that can be included with boiler. Retain this Article if venting kit is included with boiler; otherwise, specify kit in Division 23 Section "Breechings, Chimneys, and Stacks."


    • [DOC File]www.pfd.miamioh.edu

      https://info.5y1.org/motorized-damper-120v_1_5ab5a0.html

      A. Provide 120V power to a motorized auto control relief damper at the west wall of room 35. Obtain power from LPM-28, which serves pump P-9. Refer to sketch H-7A for damper location. Provide toggle type disconnect.


    • [DOC File]www.shareddocs.com

      https://info.5y1.org/motorized-damper-120v_1_f1a4b0.html

      Two-Position Motorized Damper: Damper shall be a 2-position damper. Damper travel shall be from the full closed position to the field adjustable %-open setpoint. Damper shall include adjustable damper travel from 25% to 100% (full open). Damper shall include single or dual blade, gear driven dampers and actuator motor.


    • [DOC File]SECTION 230900 - INSTRUMENTATION AND CONTROLS FOR HVAC

      https://info.5y1.org/motorized-damper-120v_1_1705d9.html

      Damper Position Indication: Where called for in the sequence of operations or on the drawings, provide a means of indicating damper position. ... Motorized control valves, pressure independent type, for use in variable flow heating and chilled water systems: ... The UPS shall be fed by 120V AC emergency power circuits. The UPS shall be floor or ...


    • [DOC File]Suffolk County Community College

      https://info.5y1.org/motorized-damper-120v_1_657b1a.html

      Internal motorized combustion air damper w/ electrical interlocks. Low water cutoff, manual reset high limit. ... 120V Power, 24V power to Valves: Per Valve: Open-Auto Switch, Valve open light, valve failure light, internal push-to-test function (2) BIV-3-24 Motorized butterfly valve, 3” lug, 24VAC, suitable for BMK- 1000/1500.


    • [DOC File]Guide Specifications - 50HC**04-14 With EnergyX

      https://info.5y1.org/motorized-damper-120v_1_b884a7.html

      The economizer damper shall be motorized with factory installed, 24-volt Belimo actuator. (3.) The EnergyX shall be capable of using the economizer in a free cooling operation. ... Outlet shall be powered from a separate 115/120v power source. (2.) A transformer shall not be included.


    • [DOC File]Section 15800 - Automatic Temperature Controls

      https://info.5y1.org/motorized-damper-120v_1_bdb9ec.html

      The damper is to be sized so that, when wide open, the pressure drop is a sufficient amount of its close-off pressure drop to shift the characteristic curve to near linear. ... Maximum clamping voltage shall not exceed 350V peak for a 120V nominal voltage source at 3,000 ampheres, 8 x 20 microsecond waveform. ... 11. End switch shall verify ...