[DOC File]SECTION 28 31 11 - DIGITAL, ADDRESSABLE FIRE ALARM …
https://info.5y1.org/nema-enclosure-types-pdf_1_4f1be4.html
The A.T.S. shall be housed in a separate NEMA [1] [3R] enclosure from the fire pump controller and labeled "Automatic Transfer Switch - Fire Pump." A complete wiring diagram shall be provided for field wiring to the emergency power source and the electric fire pump controller.
[DOC File]Part 1 - Cummins Inc.
https://info.5y1.org/nema-enclosure-types-pdf_1_068e3f.html
The enclosure shall have hinged access doors as required to maintain easy access for all operating and service functions. All doors shall be lockable, and include retainers to hold the door open during service. Enclosure roof shall be designed to prevent rainwater accumulation. Openings shall be screened to limit access of rodents into the ...
[DOC File]SECTION 263600 - TRANSFER SWITCHES
https://info.5y1.org/nema-enclosure-types-pdf_1_73c39c.html
Refer to the Project drawings for specifications on the sizes and types of transfer switch equipment, withstand and closing ratings, number of poles, voltage and ampere ratings, enclosure type, and accessories. Main contacts shall be rated for 600 VAC minimum.
[DOC File]PSG Section 26 28 16.13 - Eaton
https://info.5y1.org/nema-enclosure-types-pdf_1_b52be5.html
Other types, where noted, shall be: NEMA 3R rainproof. NEMA 1 plug fuse indoor. Paint color shall be ANSI 61 gray. 30 A to 60 A NEMA 1 enclosures shall have tangential knockouts on the top, bottom and sides of the enclosure. NEMA 3R enclosures shall have tangential knockouts on the bottom and sides. (Not applicable to NEMA 1 plug-fuse type).
SECTION 260513 - MEDIUM VOLTAGE CABLE
The conductor strand shield shall be both a 2.5 mil thick extruded semiconducting material in conformance with Paragraph 2.7, ICEA S-93-639 NEMA WC 7 or extruded energy suppression and stress control material having the necessary characteristics to perform the …
[DOC File]PSG Section 16441A - Eaton
https://info.5y1.org/nema-enclosure-types-pdf_1_b92f43.html
Other types, where noted, shall be: NEMA 3R rainproof. NEMA 1 plug fuse indoor. Paint color shall be ANSI 61 gray. 30 A to 60 A NEMA 1 enclosures shall have tangential knockouts on the top, bottom and sides of the enclosure. NEMA 3R enclosures shall have tangential knockouts on the bottom and sides. (Not applicable to NEMA 1 plug-fuse type).
[DOC File]Emergency Lighting Inverter Installation and Operation Manual
https://info.5y1.org/nema-enclosure-types-pdf_1_125d5a.html
All system components shall be housed in a single floor mounted freestanding NEMA 1 enclosure. The cabinet should have front access only with two doors, allowing easy component access from the front. The enclosure shall have shelves for component separation and clear and accessible layout. Cabinet doors shall require a key for gaining access.
[DOC File]SECTION 23 2123 - HYFAB
https://info.5y1.org/nema-enclosure-types-pdf_1_70f632.html
NEMA Compliance: Electric motors and components shall be listed and labeled NEMA. ANSI/HI 1.1-1.4, 1.6 – 2000, Nomenclature, Definitions, Applications, Operation and Testing. ANSI/HI 9.6.1-1998, NPSH Margin. ANSI/HI 9.6.3-1997 Operating Region. ASTM 48, Standard Specification for …
[DOC File]A & E GUIDE Specifications for Siedle Intercom 3000 ...
https://info.5y1.org/nema-enclosure-types-pdf_1_eee324.html
Oct 01, 2006 · Wall mount control enclosure shall comply with UL 50 Type 1, NEMA/EEMAC Type 1, CSA Type 1, IEC 529, 1P39. Wall mount control enclosure shall be equipped with removable door with butt hinges, ground and lock kit. The dimensions shall be minimum and selected according to required system feature. - 42 x 36 x 8 enclosure (39 x 33 panel)
[DOC File]Microsoft Word
https://info.5y1.org/nema-enclosure-types-pdf_1_fd41b2.html
4.1 Enclosure: All system components shall be housed in a single floor mounted small footprint (39”x 18”), freestanding NEMA 1 enclosure. The cabinet should have front access only with two doors and the depth of no more than 18 inch, allowing easy component reach from the front.