Nema ratings table
[PDF File]BOSTON EDISON COMPANY (BECo)
https://info.5y1.org/nema-ratings-table_1_00c225.html
Table of Credit Exposure Limits. This table sets forth the maximum unsecured credit exposure that NSTAR Electric may have to any individual entity based on its credit rating tier. The applicable credit rating tier is based on an entity’s senior unsecured debt ratings, or in the absence of such ratings, the entity’s Corporate Credit ratings.
[DOC File]Informative Annex 9
https://info.5y1.org/nema-ratings-table_1_a1ad66.html
IP & NEMA Ratings & Enclosures. ... The wording in the table is not exactly as used in the standards document, but the dimensions are accurate. The first digit in the rating is the protection against contact and foreign bodies. The second digit in the rating is the water protection factor. The third digit in the impact protection factor It is ...
[DOCX File]Liquid-filled, medium-voltage AR-VFI unit substation ...
https://info.5y1.org/nema-ratings-table_1_0a1b74.html
NEMA TR 1-1993 (R2000) – Transformers, Regulators and Reactors, Table 0-2 Audible Sound Levels for Liquid-Immersed Power Transformers. NEMA 260-1996 (2004) – Safety Labels for Pad-Mounted Switchgear and Transformers Sited in Public Areas.
[DOC File]Medium Voltage Metal-Clad Switchgear Specification
https://info.5y1.org/nema-ratings-table_1_b1b535.html
The switchgear shall meet (NEMA 1 indoor construction / NEMA 1A indoor gasket construction / NEMA 3R walk-in outdoor construction / NEMA 3R non walk-in outdoor construction). The switchgear will be used in a (X) kV, 3-phase, 60 Hz system. ... Table 1 provides the required ratings and related capabilities of circuit breakers utilized in ...
[DOCX File]Section 23 05 12 - GENERAL MOTOR REQUIREMENTS FOR …
https://info.5y1.org/nema-ratings-table_1_bc5411.html
NEMA Premium Efficiency Electric Motors (Motor Efficiencies): All permanently wired polyphase motors of 746 W (1 hp) or more shall meet the minimum full-load efficiencies as indicated in the following table. Motors of 746 W (1 hp) or more with open, drip-proof, or TEFC enclosures shall be NEMA premium efficiency type, unless otherwise indicated.
[DOC File]NEMA FAQ – Grouped
https://info.5y1.org/nema-ratings-table_1_640d17.html
The NEMA 250 standard has correlation tables for this. The NEMA 250 standard is available from IHS, ANSI, and Techstreet. How do the water test parameters compare between NEMA 250 hose testing and IEC 60529 IP hose testing? See the table below.
[DOC File]ABB
https://info.5y1.org/nema-ratings-table_1_f9d4b4.html
The VFD package as specified herein and defined on the VFD schedule shall be enclosed in a UL Type enclosure (enclosures with only NEMA ratings are not acceptable), completely assembled and tested by the manufacturer in an ISO9001 facility. The VFD shall provide full rated output from a …
[DOCX File]Liquid-filled, medium-voltage unit substation transformer ...
https://info.5y1.org/nema-ratings-table_1_b5fcff.html
NEMA® TR 1-1993 (R2000) – Transformers, Regulators and Reactors, Table 0-2 Audible Sound Levels ... (For standard BIL transformers select LV and BIL ratings from Table 1 using the standard transformer column for BIL. For Critical load (CLT) or Hardened Datacenter (HDC) designs requiring higher BIL ratings select LV and BIL from table 1 using ...