Olympus, Pentax, and Fujinon endoscopes are compatible with CIDEX OPA Solution. If questions arise regarding the compatibility of a device with CIDEX OPA Solution, contact the device manufacturer. Cleaning Agent Compatibility: CIDEX OPA Solution is compatible with enzymatic detergents which are mild in pH, low foaming, and easily rinsed from ...
[DOC File]The following offer is made, by Pacific Surgical LLC, in ...
https://info.5y1.org/olympus-endoscope-cleaning-policy_1_9103db.html
RSR02 Complete interior cleaning, repolishing of fiber optics and windows, optical adjustment, complete shock test $395.25 15-months RSR03 Opening and cleaning of scope, optical and light fiber polishing, Repair of minor kinks and realignment of stainless steel tube, replacement of window, up to 2 rod lenses, cleaning of lens system, complete ...
[DOC File]GSA Advantage!
https://info.5y1.org/olympus-endoscope-cleaning-policy_1_eb11b8.html
DS2032 Light Source Repair - All manufacturers including Olympus Flexible Endoscope Light Sources Repair Mechanical Problems $500.00-750.00 A-200. DS2033 Light Source Repair - All manufacturers including Olympus Flexible Endoscope Light Sources Clean and Re-calibrate $750.00-1600.00 A-200
[DOCX File]HICPAC Sample Policy Template: Reprocessing Flexible ...
https://info.5y1.org/olympus-endoscope-cleaning-policy_1_cf5857.html
The policy document will provide guidance to personnel for processing all types of reusable flexible endoscopes and accessories. Policy. It is the policy of ... Clean all accessible channels and the distal end of the endoscope with a cleaning brush of the length, width, and material recommended by the endoscope manufacturer. ...
[DOCX File]HICPAC Sample Audit Tool: Reprocessing Flexible Endoscopes
https://info.5y1.org/olympus-endoscope-cleaning-policy_1_f2c3c0.html
Uses a clean brush for each endoscope cleaning. If the endoscope has an elevator, raises and lowers the elevator throughout the manual cleaning process. ... and sterilizes endoscopic accessories that enter sterile tissue or the vascular system per the health care facility’s policy and procedure.
[DOC File]University of Michigan
https://info.5y1.org/olympus-endoscope-cleaning-policy_1_a6a638.html
Compared observed sites’ endoscope reprocessing to best practices found in Infection Control’s endoscope reprocessing policy [2]. Using the detailed observation data gathered, the team compared each site to the best practices and determined a percent of best practice that each site was following.
[DOCX File]Association of periOperative Registered Nurses | AORN
https://info.5y1.org/olympus-endoscope-cleaning-policy_1_47f174.html
Cleans all accessible channels and the end of the endoscope with a cleaning brush of the length, width, and material recommended by the endoscope manufacturer. ... Sterilizes endoscopic accessories that enter sterile tissue or the vascular system per the health care facility’s policy and procedure.