Precleans flexible endoscopes and accessories at the point of use as soon as possible after the endoscope has been removed from the patient (or the procedure is completed) and before organic material has dried on the surface or in the channels of the endoscope.
[DOCX File]Association of periOperative Registered Nurses | AORN
https://info.5y1.org/olympus-endoscope-reprocessing-manual_1_47f174.html
Washes the exterior surface of the endoscope with the cleaning solution and a soft, lint-free cloth or sponge. ... raises and lowers the elevator throughout the manual cleaning process and manually actuates the valves. ... Follows policy for removing and reprocessing the endoscope before use if the maximum storage time has been exceeded. Author ...
cantelmedical.gcs-web.com
SECURITIES AND EXCHANGE COMMISSION. Washington, D.C. 20549. Form 10-K. Annual Report pursuant to Section 13 or 15(d) of the. Securities Exchange Act of 1934. For the fiscal year e
cantelmedical.gcs-web.com
Hu-Friedy is a leading global manufacturer of instruments and instrument reprocessing systems serving the dental industry and is included in our Dental segment. During the second quarter of fiscal 2020, we paid $25,000 to settle a portion of the contingent consideration arrangements related to net sales achieved for the twelve month period ...
[DOC File]March 14, 2005 - Olympus America
https://info.5y1.org/olympus-endoscope-reprocessing-manual_1_6af0a7.html
Continuous reprocessing through the steps indicated in the Olympus endoscope manual ensures that patient fluids and debris do not begin to dry and harden on the endoscope external surfaces and within the endoscope channels. If reprocessing has been delayed after endoscope precleaning, resulting in patient fluid or debris drying onto the surface ...
[DOCX File]March 20, 2007
https://info.5y1.org/olympus-endoscope-reprocessing-manual_1_c51a81.html
In addition to the new cleaning brush referenced above, the new TJF-145 reprocessing procedures require additional flushing and forceps elevator raising/lowering steps during precleaning and manual cleaning, manual disinfection, endoscope rinsing and alcohol flushing. The new Reprocessing Manual is enclosed with this letter.
[DOC File]University of Michigan
https://info.5y1.org/olympus-endoscope-reprocessing-manual_1_a6a638.html
The team researched and found many useful references from journal articles and manufacturers instructions on endoscope reprocessing guidelines and typical audit tools off which to base their recommendations. Compared observed sites’ endoscope reprocessing to best practices found in Infection Control’s endoscope reprocessing policy [2].
[DOCX File]HICPAC Sample Audit Tool: Reprocessing Flexible Endoscopes
https://info.5y1.org/olympus-endoscope-reprocessing-manual_1_f2c3c0.html
If the endoscope has an elevator, raises and lowers the elevator throughout the manual cleaning process. Brushes the accessible channels until no debris appears on the brush. Removes debris before retracting the brush back through the endoscope.