      10–110 mm distal to the stent, with varying severity depending on stent type (Fig. 4). The Palmaz stent showed Fig. 4 Distributions of time-averaged wall shear stress for the Palmaz, NuMED CP, and Genesis XD stents. CFD results for the full model are shown next to spatial maps that have been unwrapped


    • [PDF File]Cordis Endovascular Catalog

      https://info.5y1.org/palmaz-genesis-stent-mri_1_3346ad.html

      S M A R ®T CONTROL Biliary Stent 59 S M A R T ® Flex Biliary Stent 60 Balloon-Expandable Biliary Stents . . . . . . . . . . . . . . 62 PALMAZ BLUE® Transhepatic Biliary Stent 62 PALMAZ GENESIS® Transhepatic Biliary Stent 64


    • [PDF File](Large) - Cardinal Health

      https://info.5y1.org/palmaz-genesis-stent-mri_1_e2097e.html

      The PALMAZGENESIS™ Stent on OPTA™ PRO .035” Delivery System can be used with other Cordis product family. The products listed hereunder are only a selection. Please contact your local sales representative for further information on product compatibilities. The PALMAZ GENESIS™ on OPTA™ Pro Stent can be used with other Cordis product ...


    • [PDF File]ContACt your medtroniC sAles representAtive (mm) 20 30 40 ...

      https://info.5y1.org/palmaz-genesis-stent-mri_1_056b25.html

      PALMAZ GENESIS (8 mm x 59 mm) EXPRESS LD (8 mm x 57 mm) 5.80 6.84 8.15 * Bench data on file at Medtronic, Inc., compares the Assurant Cobalt stent with the Cordis Palmaz Genesis stent and the Boston Scientific Express LD stent. Bench test results may not be indicative of clinical performance.


    • [PDF File]PALMAZ GENESIS on OPTA Pro Stent - Cardinal Health

      https://info.5y1.org/palmaz-genesis-stent-mri_1_cb9d4b.html

      The PALMAZ ™GENESIS on OPTA™ Pro Stent can be used with other Cordis product family. The products listed hereunder are only a selection. please contact your local sales representative for further information on product compatibilities. Diameter Taper Length Catalogue


    • Fate of the Fontan connection: Mechanisms of stenosis and ...

      Cheatham Platinum stent was placed in six patients. In one patient with a lateral tunnel Fontan (Figure 1), a covered stent was used to avoid risk for development of right to left shunt and in the remain‐ ing patients it was used to protect against disruption of a calcified, stenotic homograft. In six patients, multiple stents were implanted at


    • Two Cases of Carotid Artery Stenting Combined Balloon- and ...

      Two Cases of CAS Combined Balloon- and Self-Expanding Stent. of the common and external carotid arteries, pre-dilation . was performed using a Gateway (Stryker) 3 mm × 12 mm, and a Palmaz genesis 5.0 mm × 18 mm was placed (Fig. 4C). In addition, a Wallstent 8 mm × 21 mm was placed by over-lapping about half of its length with the Palmaz (Fig ...


    • [PDF File]Balloon Expandable Stents for Coarctation of the Aorta ...

      https://info.5y1.org/palmaz-genesis-stent-mri_1_f3a6c0.html

      stent designs as well as introduction of new stents has been accomplished in the recent years. The Palmaz-GenesisTM stent (Cordis/Johnson and Johnson) was introduced to overcome some of the short falls of the Palmaz stents. The authors reported here the first five patients who had coarcatation of the aorta and stenting by the Palmaz-GenesisTM ...


    • [PDF File]Cordis PaLMaz Blue

      https://info.5y1.org/palmaz-genesis-stent-mri_1_13290a.html

      PaLMaz Blue has been shown to be MR safe at field strengths of 3.0 Tesla (test conditions described in IFU) The PaLmaz® & PaLmaz® Genesis™ Heritage The Gold Standard The PaLMaz® Blue™ .018 incorporates the proven design of the PaLMaz® and PaLMaz® Genesis™ balloon-expandable stent family: Closed Cell Design for optimal scaffolding


    • Use of Palmaz Stents in a Newborn With Congenital ...

      tion followed by the placement of a Palmaz Genesis PG184 stent at the most distal aspect of narrowing via a 4-French catheter delivery system. The most proxi-mal stent was initially inflated using a 4-mm Ranger balloon, followed by inflation with a 5-mm Tyshak II Fig. 1. Coronal view MRI image demonstrates the location of the lower thoracic ...


    • [PDF File]The role of stents in the treatment of congenital heart ...

      https://info.5y1.org/palmaz-genesis-stent-mri_1_75ab15.html

      Ann Pediatr Card 2009 Vol 2 Issue 1 5 Peters, et al.: Stents in congenital heart disease Thus, older Palmaz stents such as the Palmaz 8 series (P 108, P188, P308) and others have been replaced by the


    • Quantification of Local Hemodynamic Alterations Caused by ...

      on stent type (Figure 4). The Palmaz stent showed two focal regions of elevated TAWSS in the dAo. The first initiated along the outer right luminal surface ~10 mm distal to the stent and extended to the center and then the outer left surface over ~40 mm. The second was located 75–100 mm distal to the stent along the outer right luminal surface.


    • [PDF File]DEC %1 % 0

      https://info.5y1.org/palmaz-genesis-stent-mri_1_d62cb4.html

      PALMAZ GENESIS Transhepatic Biliary Stent on OPTA PRO .035" Delivery System (ref. 510(k) #K012590) with no change to the indication for use or to the fundamental scientific technology of the predecessor device. Stent: The PALMAZ GENESIS Transhepatic Biliary stent is a balloon expandable,


    • [PDF File]Pre-mounted PALMAZ GENESIS Stent - Cardinal Health

      https://info.5y1.org/palmaz-genesis-stent-mri_1_7c2a42.html

      The PALMAZ® GENESIS ™ Stent on OPTA Pro can be used with other Cordis product family. the products listed hereunder are only a selection. Please contact your local sales representative for further information on product compatibilities. Cannula usable length Catalogue Number Catalogue Number Catalogue Number (cm) 6F 8F7F


    • [PDF File]SUMMARY OF SAFETY AND EFFECTIVENESS DATA 1. General ...

      https://info.5y1.org/palmaz-genesis-stent-mri_1_0647f0.html

      Page 1 – Cordis PALMAZ Stent (Renal Indications) – P980017/S10 . POWERFLEX PLUS 1 3. Device Description The PALMAZ Balloon-Expandable Stent is a 316L stainless steel, slotted tube which is expand ed with the use of the recommended delivery systems (refer to Table 1).


    • [PDF File]Transcatheter Stent Therapy in Children: An Update

      https://info.5y1.org/palmaz-genesis-stent-mri_1_ded984.html

      Palmaz stent and the DoubleStrut stents are still available, they have ... mostly been replaced by the Genesis, Mega LD and Max LD stents. ... for re-expansion to adult size, 8) open cell design, 9) MRI compatible, 10) low risk of neo-intimal proliferation and 11) biodegradable



    • [PDF File]English PALMAZ GENESIS 0086

      https://info.5y1.org/palmaz-genesis-stent-mri_1_be737a.html

      The PALMAZ GENESIS Peripheral Stent is a balloon-expandable, laser cut stent made from 316L stainless steel tubing. The stent is supplied in two nominal lengths: 29 mm and 39 mm. Specific expansion ranges for each stent length are shown in Table 1.


    • [PDF File]Long-term fate and function of stents implanted in CHD

      https://info.5y1.org/palmaz-genesis-stent-mri_1_1d2f39.html

      Ing-TCTAP, 2014 JPICS stent survey: medium and long-term outcomes • Palmaz or Palmaz Genesis stents • Branch PA, COA, SVC, IVC • 5/95-2/09 (14 yrs); 14 hospitals


    • [PDF File]PALMAZ GENESISTM Peripheral Stent on - Cordis

      https://info.5y1.org/palmaz-genesis-stent-mri_1_6b0c90.html

      The PALMAZ GENESIS Peripheral Stent is a balloon-expandable, laser cut stent made from 316L stainless steel tubing. The stent is sold mounted on a Cordis percutaneous transluminal angioplasty (PTA) balloon catheter. It is available in diameters of 5.00 - 7.00 mm Delivery System


    • [PDF File]Cordis EMEA Endovascular Catalog - Cardinal Health

      https://info.5y1.org/palmaz-genesis-stent-mri_1_077363.html

      PALMAZ® GENESIS™ on OPTA™ PRO (MEDIUM) 10 ... • Excellent stent retention The Genesis family offers a complete range of lengths and diameters in combination with pre-mounted and stent-alone configurations. Cobalt Chromium L605