Palmaz schatz stent mri safe

    • [PDF File]5945 Review Article Magnetic resonance imaging of patients with airway ...

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_283e8f.html

      stents are safe for patients who must undergo MRI. However, the safety of SS stents depends on the type of steel used. Keywords: Magnetic resonance imaging (MRI); airway stents; safety; stainless steel stents (SS stents); nickel-titanium alloy stents Submitted May 09, 2018. Accepted for publication Sep 20, 2018. doi: 10.21037/jtd.2018.09.132


    • [PDF File]Guidelines for the Management of Patients with Coronary Artery ... - ISMRM

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_dbd704.html

      MRI labeling information exists for many coronary artery stents (3, 22). By following the pertinent MRI labeling information (i.e., presented in the Instructions for Use, Patient Identification Card, etc.), patients with coronary artery stents have safely undergone MRI examinations, including those performed at 1.5- and 3-Tesla.


    • Case Reports Superimposed Stents in the Management of Acute Recoil ...

      After Palmaz-Schatz Stenting Robert J. Lederman, MD, and Mauro Moscucci,* MD We report a patient in whom aorto-ostial stenting with a Palmaz-Schatz coronary stent was complicated by significant acute elastic recoil, despite appropriate positioning of the stent and full expansion of a high-pressure, postdilatation balloon. Superimposing a



    • [PDF File]MRI Safety Promus PREMIER™ Everolimus-Eluting Platinum Chromium ...

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_5b2a29.html

      MRI following the placement of a Promus PREMIER Stent. Section 6.11 Magnetic Resonance Imaging (MRI) Safety Information . Non-clinical testing has demonstrated that the Promus PREMIER Stent is MR Conditional for single and overlapped conditions up to 74mm. A patient with this device can be safely scanned in an MR system meeting the following


    • [PDF File]Intravascular Palmaz-Schatz stent - Heart

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_85a3a8.html

      thefirst 30daysafterstentplacement. Patientsandmethods We studied 126 patients with symptomatic ischaemic heart disease who underwent suc-cessful intracoronary stent placement after balloon angioplasty (PTCA) at our hospital. Successful stent implantation was defined as stent placement at the desired position, a residual stenosis ofless than 10 ...


    • [PDF File]SUMMARY OF SAFETY AND EFFECTIVENESS DATA 1. General Information

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_0647f0.html

      The PALMAZ ® Balloon Expandable Stent, Model P308, was approved on September 29, 19991 (P890017) for use following a suboptimal angioplasty procedure of the common or external iliac arteries. The sponsor submitted this supplement for the PALMAZ® Balloon Expandable Stent, Models P104R, P154R and P204R, to expand the indication for use in the


    • Endovascular Treatment of Superior Mesenteric Artery Pseudoaneurysms ...

      ported the first case of covered stent place-ment in 1998 using an autogenous vein–cov-ered stent with a balloon-expandable stent (Palmaz P294, Johnson & Johnson). Since then, the use of covered stents to treat SMA pseudoaneurysms has been reported in case reports [4–28]. Although the previous stud-ies were of one or two cases each, these case


    • [PDF File]Coronary Arterial Stents: Safety and Artifacts during

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_47a8ba.html

      Palmaz-Schatz Johnson & Johnson 15 3.5 R-Stent Spectranetics 16 3.0 Seaquence Nycomed Amersham 15 3.5 Wallstent Schneider 23 4.5 Wiktor GX Medtronic AVE 15 4.0 *Inflow Gold stents are composed of 316 low-carbon stainless steel with a gold plate. The Wallstent is composed of a cobalt-based alloy with a platinum core. The Wiktor GX stent is ...


    • [PDF File]Table of Contents - Boston Scientific

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_6a5ebb.html

      Boston Scientific Corporation Customer Service: 888‐272‐1001 www.bostonscientific.com Page 1 of 12 PI‐86716‐AG Magnetic Resonance Imaging (MRI) Safety for


    • [PDF File]POTENTIAL ADVERSE EVENTS 2 CLINICAL STUDIES 2 6 Innova Vascular 3 6 - US

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_a3a982.html

      of tantalum increase visibility of the stent to aid in placement. The stent is constrained within a 6F (2.1 mm maximum OD) delivery system. The delivery system is a triaxial design with an outer shaft to stabilize the stent delivery system, a middle shaft to protect and constrain the stent, and an inner shaft to provide a guidewire lumen.


    • [PDF File]Facilitated Advancement of the Palmaz-Schatz Stent Delivery System With ...

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_1906c1.html

      Palmaz-Schatz Stent Delivery System With the Use of an Adjacent 0.018 Stiff Wire Jorge F. Saucedo, MD, David W.M. Muller, MBBS, FSCAI, and Mauro Moscucci, MD The 5.0 French Palmaz-Schatz stent delivery system is a rela- tively bulky, stiff system which can be advanced only over a 0.014” wire. Although crossing failure is rare, advancement of


    • [PDF File]Cordis PALMAZ Blue - Cardinal Health

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_0bb9ce.html

      PALMAZ Blue™ has been shown to be MR safe at field strengths of 3.0 Tesla (test conditions described in IFU) The Gold Standard The PALMAZ Blue™ .018 incorporates the proven design of the PALMAZ™ and PALMAZ Genesis™ balloon-expandable stent family: Closed Cell Design for optimal scaffolding One Piece Laser Cut Tube


    • [PDF File]Start here - Boston Scientific

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_e1f273.html

      The Express SD Renal Stent has been shown to be MR safe at field strength of 3 Tesla (T) or less, and a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 15 minutes of MR imaging. ... This stent has not been evaluated to determine if it is safe in MRI systems with field strengths greater than 3T. Created Date: 1/26/2012 ...


    • [PDF File]8. MAGNETIC RESONANCE IMAGING (MRI) SAFETY INFORMATION2 5 2 5 2 5 2 9 ...

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_81a8cf.html

      2 Boston Scienti≥c, (Master Brand DFU Template 8.2677in x 11.6929in A4, 92238519A), eDFU, MB, VENOUS WALLSTENT, en 50607601-01B Black (K) ≤E fl5.0 • 8.2. Image Artifact Implanting a stent may lead to dissection of the vessel distally, and/or proximally, to the stented portion, and may cause acute


    • [PDF File]Cordis PaLMaz Blue - viSole

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_6c20d8.html

      PaLMaz Blue has been shown to be MR safe at field strengths of 3.0 Tesla (test conditions described in IFU) The PaLmaz® & PaLmaz® Genesis™ Heritage The Gold Standard The PaLMaz® Blue™ .018 incorporates the proven design of the PaLMaz® and PaLMaz® Genesis™ balloon-expandable stent family: Closed Cell Design for optimal scaffolding


    • [PDF File]Cordis PALMAZ Blue

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_55b790.html

      PALMAZ Blue™ has been shown to be MR safe at field strengths of 3.0 Tesla (test conditions described in IFU) The Gold Standard The PALMAZ Blue™ .018 incorporates the proven design of the PALMAZ™ and PALMAZ Genesis™ balloon-expandable stent family: Closed Cell Design for optimal scaffolding One Piece Laser Cut Tube


    • [PDF File]CoronaryPalmaz-Schatz stent implantation acute myocardialinfarction - Heart

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_a458df.html

      Conclusions-Coronary stenting is a safe and effective treatment for complicated direct balloon angioplasty in acute myocardial infarction. In patients with ... intracoronary Palmaz-Schatz stent implanta-tion after direct PTCA in acute myocardial infarction between 1 May 1992 and 30 April 1995. All 80 presented within 48h of the onset of pain.


    • [PDF File]NIRflexTM Premounted Coronary Stent System Instructions for Use

      https://info.5y1.org/palmaz-schatz-stent-mri-safe_1_8808e8.html

      Do not perform magnetic resonance imaging (MRI) scan on patients post-stent implantation until the stent has been completely endothelialized (approximately eight ... along with those receiving the NIR@ Primo Stent system and the Palmaz- Schatz@ Stent (NIRVANA Study) during 6 months. NIRflexTM Premounted Coronary Stent System Instructions for Use