Portable liquid flow meters

    • [DOC File]Technical Manual, Sec. 2, Ch. 3: Technical Equipment: On ...

      https://info.5y1.org/portable-liquid-flow-meters_1_2c453b.html

      Low flow air sampling methods consist of traditional personal sampling pumps equipped with capture devices such as filter media or liquid impingers. These low flow methods have the advantage of being small and portable; however, due to their low sample volume they will have a relatively high limit of detection.


    • [DOCX File]Section 22 05 19 - METERS AND GAGES FOR PLUMBING PIPING

      https://info.5y1.org/portable-liquid-flow-meters_1_ece72f.html

      //Install portable water temperature, pressure and flow meters provided under Section 23 09 23 DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC.// FIELD QUALITY CONTROL The meter assembly shall be visually inspected and operationally tested.


    • [DOC File]SECTION 1 – GENERAL

      https://info.5y1.org/portable-liquid-flow-meters_1_eb2048.html

      OPTIONAL: Meters may be specified with ±0.2% accuracy. User Interface: Reading shall be displayed on a local LCD display. The display shall have two rows of sixteen [16] characters per row. The consumption shall be up to six digits. Provide an IEC-type optical data port capable of connection to a portable computer.


    • [DOC File]SECTION 230519 - METERS AND GAGES FOR HVAC PIPING

      https://info.5y1.org/portable-liquid-flow-meters_1_78d32a.html

      Permanently Mounted Meters for Flow Elements: Install meters on walls or brackets in accessible locations. Install connections, tubing, and accessories between flow elements and meters as prescribed by manufacturer's written instructions. Portable Meters Turn-over portable meters to the Owner upon completion of the project.


    • [DOCX File]23 05 19

      https://info.5y1.org/portable-liquid-flow-meters_1_ac28bb.html

      Install meters and gauge so a 5´-10" person can read the meters and gauges while standing on finished floor. For pumps, install pressure gage taps in pump flange taps, pumps shall have flange taps. Install pressure gage taps in the chiller's evaporator manifold taps, chillers shall have manifold taps.


    • [DOCX File]213116 – Diesel-Drive, Centrifugal Fire Pumps

      https://info.5y1.org/portable-liquid-flow-meters_1_f02c95.html

      Portable Flowmeter: With two 3.7-m (12-ft.) hoses, in carrying case. ... Connect flowmeter-system sensors and meters. Connect controllers to pumps. ... Observe leakage from stuffing boxes and adjust sealing-liquid valve for proper flow to ensure lubrication of packing. Do not tighten gland immediately, but let packing run in before reducing ...


    • [DOC File]WATER QUALITY LABORATORY - Rowan University

      https://info.5y1.org/portable-liquid-flow-meters_1_a68862.html

      Dissolved oxygen (DO) concentration can be measured in lakes and streams using a portable DO meter. We will use the meters from the Environmental Engineering lab for our measurements of Rowan Pond. The meters indicate the concentration of dissolved oxygen in mg/L, as well as in units of “percent of saturation.”



    • [DOC File]The building comprises the entire traditional mid-terraced ...

      https://info.5y1.org/portable-liquid-flow-meters_1_c9081d.html

      And it’s very simple to set-up and operate, essential attributes for a portable instrument. The ultrasonic sensor is clamped on the outside of a pipe and an acoustic pulse is reflected back to the sensor from particles or gases in the flowing liquid. The flow rate of any fluid can be measured as long as it contains air bubbles or solids.


    • [DOCX File]Fuel Loading/Unloading Procedures

      https://info.5y1.org/portable-liquid-flow-meters_1_832715.html

      Monitor the liquid level in the receiving tank to prevent overflow. Monitor flow meters to determine rate of flow. When topping off the tank, reduce flow rate to prevent overflow. After loading/unloading. Make sure the transfer operation is completed. Close all tank and loading valves before disconnecting.


    • [DOCX File]213113 – Electric-Drive, Centrifugal Fire Pumps

      https://info.5y1.org/portable-liquid-flow-meters_1_3912fe.html

      Portable Flowmeter: With two 3.7-m (12-ft.) hoses, in carrying case. ... Connect flowmeter-system sensors and meters according to manufacturer's written instructions. ... Observe leakage from stuffing boxes and adjust sealing-liquid valve for proper flow to ensure lubrication of packing. Do not tighten gland immediately, but let packing run in ...


    • Specifications, Tolerances, and Other Technical ...

      (b)a means for reading the level of liquid in the tank, such as a removable gauge rod or surface gauge; and (c)a chart for converting level-of-liquid readings to volume. Each compartment of a subdivided tank shall, for the purposes of this code, be construed to be a farm milk tank. S.2.Design of Tank. S.2.1.Level.


    • [DOC File]SOPs for Small Drinking water Systems

      https://info.5y1.org/portable-liquid-flow-meters_1_1d615f.html

      Treatment - Liquid Chlorine (hypochlorite) Undiluted strength (5%, 12.5%, etc.) Target chlorine residual at entry point to system (ppm) Day tank capacity (gal) Chlorine to water. mix ratio Day tank filling instructions Pump make and model Maximum pump rate (gpm or gph) Typical pump speed and stroke settings MSDS


    • [DOCX File]Michigan State University

      https://info.5y1.org/portable-liquid-flow-meters_1_3e499a.html

      Inline flow meters shall be installed with upstream and downstream shutoff valves at each end of the metering run. If the flow meter size is smaller than line size (if approved by Mechanical Engineer), the reducers must be on the meter sides of the shutoff valves such that the shutoff valves are line size.