Precast concrete pipe

    • Construction Specification 42—Concrete Pipe Conduits and ...

      Pipe to be cradled or bedded on concrete shall be set to the specified line and grade and temporarily supported on precast concrete blocks or wedges until the cradle or bedding concrete is placed. Concrete blocks or wedges used to temporarily support the pipe during placement of bedding or cradle shall be of a class of concrete equal to or ...

      precast concrete products


    • [DOC File]Precast Modular Block Retaining Wall Specification

      https://info.5y1.org/precast-concrete-pipe_1_e55a98.html

      C. Concrete used for construction of an unreinforced concrete leveling pad shall satisfy the criteria for AASHTO Class B. The concrete should be cured a minimum of 12 hours prior to placement of the precast modular block wall retaining units and exhibit a minimum 28-day compressive strength of 2,500 psi (17.2 MPa). 2.05 DRAINAGE . A. Drainage ...

      hanson precast concrete products


    • (2411) MECHANICALLY STABILIZED EARTH WALLS WITH …

      Aug 31, 2011 · 8.Use an approved mix design meeting the requirements of 2462, “Precast Concrete”, with an air-entrained mix and a minimum compressive strength of 4,000 psi meeting the requirements of 2462, “Precast Concrete.” Use coarse aggregate meeting the requirements of 3137.2.D.2, “Coarse Aggregate for Bridge Superstructure.”

      concrete pipe and precast sc


    • [DOCX File](2462) PRECAST CONCRETE

      https://info.5y1.org/precast-concrete-pipe_1_cc67fe.html

      Use when there are precast concrete products: bridge girders, noisewall posts or panels, box culverts, retaining wall blocks, RC pipe, precast concrete barrier, etc. This is a correction to the spec book. (2462) PRECAST CONCRETE. REVISED 04/09/20 DO NOT REMOVE THIS “REVISED” DATE.

      concrete pipe & precast llc


    • [DOCX File]Materials Source List - Illinois Department of Transportation

      https://info.5y1.org/precast-concrete-pipe_1_853982.html

      Precast Concrete. List Precast, Prestressed Concrete. IL OK Timber. Cert. or Mark or LA 15 Pipe, Culvert & Drain. Cast or Ductile Iron Pipe. Cert. or LA 15 Clay Pipe & Drain Tile. LA 15 or IL OK or Test Metal Corrugated & Components. Cert. or IL OK or LA 15 Pipe-Plastic, PVC, HDPE-water/sewer. IL OK or LA 15 or Test Pipe Fittings – PE, PVC ...

      precast concrete drainage pipe


    • [DOC File]Construction Specification 42—Concrete Pipe Conduits and ...

      https://info.5y1.org/precast-concrete-pipe_1_e1dce3.html

      Before the concrete or earth backfill is placed around the conduit joint to be tested, the joint shall be tested in accordance to ASTM C 1103, Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines. Any joints showing leaks shall be relaid or repaired, and the joint shall be retested.

      concrete pipes suppliers


    • [DOCX File]SECTION 03 41 13, PRECAST CONCRETE HOLLOW CORE …

      https://info.5y1.org/precast-concrete-pipe_1_86c0fd.html

      Section specifies precast concrete roof planks. Designs: // channel // flat plank // steel edge flat plank. MANUFACTURER'S QUALIFICATIONS. Products of one manufacturer regularly engaged in making precast concrete planks of type specified. SUBMITTALS. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

      precast concrete pipe supports


    • [DOC File]Section 02645 - Precast Concrete Box and Three Sided ...

      https://info.5y1.org/precast-concrete-pipe_1_426ac9.html

      May 01, 2017 · Manufacture of pre-cast concrete box and three-sided culvert section must be completed in a plant where the quality assurance program has been certified by either the American Concrete Pipe Association (for box culverts) or the National Precast Concrete Association (for three-sided structures).

      concrete drain pipe


    • [DOC File]PRECAST REINFORCED CONCRETE BOX CULVERT - NCDOT

      https://info.5y1.org/precast-concrete-pipe_1_fe8fa5.html

      The precast reinforced concrete box culvert sections shall match the size and hydraulic opening indicated in the contract plans. Design Placement of Reinforcement – Provide a 1 inch concrete cover over the reinforcement subject to the provisions of Section F. Extend the inside reinforcement into the tongue portion of the joint and the outside ...

      precast concrete products


    • [DOC File]DIVISION 3 - PIPE CULVERTS

      https://info.5y1.org/precast-concrete-pipe_1_eb033f.html

      Both corrugated steel and concrete pipe end sections will work on concrete pipe, corrugated steel pipe and HDPE smooth lined corrugated plastic pipe. 310-6 MEASUREMENT AND PAYMENT. Pipe will be measured and paid as the actual number of linear feet of pipe that has been incorporated into the completed and accepted work.

      hanson precast concrete products


Nearby & related entries: