Psi testing center locations

    • [DOCX File]SECTION 01 45 29, TESTING LABORATORY SERVICES

      https://info.5y1.org/psi-testing-center-locations_1_3d59c1.html

      2.Make field density tests in accordance with the primary testing method following ASTM D6938 // AASHTO T310 // wherever possible. Field density tests utilizing ASTM D1556 // AASHTO T191 //, or // ASTM D2167 // shall be utilized on a case by case basis only if there are problems with the validity of the results from the primary method due to specific site field conditions.

      psi exams schedule


    • Contractors Material and Test Certificate for Underground ...

      (flowing) Flow rate Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow (gpm) Test. description Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.8 bar) for 2 hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.3 bar) for 2 hours.

      psi testing center locations michigan


    • [DOC File]Arranging for Blood Draws for MRT testing

      https://info.5y1.org/psi-testing-center-locations_1_53de6b.html

      ARRANGING FOR BLOOD DRAWS FOR MRT TESTING (Current Jan 2013) ... National blood draw service such as PSI (Phlebotomy Services International) ... (Caution, some FedEx locations will not ship blood.) After receiving payment for testing and/or counseling, refer for blood draw. Be sure paperwork is explained and that client knows that the DATE AND ...

      psi testing centers in michigan


    • Mansfield, TX | Official Website

      Water Main Testing. Water mains shall be pressure tested according to the NCTCOG spec (Item 506.5). Water mains to be tested at 150 psi for 4 hours, fire mains to be tested at 200 psi for 2 hours. Water samples shall be taken by City personnel.

      psi exams contact phone number


    • [DOC File]Mike Slusher’s Pump Test

      https://info.5y1.org/psi-testing-center-locations_1_629e00.html

      150 psi 1000 2” 3 x 100 ft 72 psi. 200 psi 700 1 3/4” 2 x 100 ft 60 psi. 250 psi 500 1 1/2” 1 x 100 ft 58 psi. 750 gpm pump 5 inch suction 20 feet. Pump Pressure GPM Nozzle Tip Discharge Hose Pitot Reading. 150 psi 750 1 3/4” 2 x 100 ft 68. 200 psi 525 1 1/2” 1 x 100 ft 62 psi. 250 psi 375 1 1/4” 1 x 100 ft 66 psi

      psi testing centers locations near me


    • 6 - PCI

      Testing: If there is evidence that strength of precast concrete units may be deficient or may not comply with ACI 318 (ACI 318M) requirements, fabricator will employ an independent testing agency to obtain, prepare, and test cores drilled from hardened concrete to determine compressive strength according to ASTM C 42/C 42M and ACI 318/ACI 318M.

      psi exam testing sites


    • [DOCX File]nhanow.com

      https://info.5y1.org/psi-testing-center-locations_1_ce4b64.html

      Additional accommodations, such as readers, may be available at campus testing locations and PSI testing centers, based on exam date and location. Once an accommodation is approved, the candidate should register and pay for their exam as directed (either LRP or PSI testing center). PSI will contact the candidate within 48 hours to make ...

      psi testing center locations indiana


    • Hydrant Flow Testing Procedures - Flower Mound

      Hydrant Flow Testing Procedure [02-27-2018] Individuals needing hydrant flow test data should follow the below procedure: Contact the . Engineering. department for a plan of the water lines and hydrant locations in the area you wish to test [972-874-6310];

      psi testing center near me


    • [DOC File]SECTION 033000 - CAST-IN-PLACE CONCRETE

      https://info.5y1.org/psi-testing-center-locations_1_c87153.html

      The temperature gradient between the center and the surface of the section must not exceed 20 deg F (6.6 deg C) during the first ten days of the controlled curing period. Thermocouples shall be installed by the Subcontractor’s testing agency in the center and six inches from the surface at twenty foot intervals and at the corners.

      psi exams schedule


    • [DOC File]2 - PCI

      https://info.5y1.org/psi-testing-center-locations_1_af417c.html

      Stone to Precast Concrete Anchorages: Provide anchors in numbers, types and locations required to satisfy specified performance criteria, but not less than two anchors per stone unit of less than 2 ft.2 (0.19 m2) in area and four anchors per unit of less than 12 ft.2 (1.1 m2) in area; and for units larger than 12 ft.2 (1.1 m2) in area, provide ...

      psi testing center locations michigan