Psi to flow rate formula

    • [DOC File]Natural Gas Pipeline Flow Calculations

      https://info.5y1.org/psi-to-flow-rate-formula_1_daf584.html

      Solution: Here is the information from Example #11: "Determine the flow rate of natural gas through a 12 inch diameter, 500 ft long pipeline of commercial steel, if the specific gravity of the gas is 0.65, its temperature is 80 oF, its average pressure is 500 psia, and the pressure drop across the 500 ft of pipe is 20 psi."

      calculate flow rate from psi


    • [DOC File]California State University, Northridge

      https://info.5y1.org/psi-to-flow-rate-formula_1_92b92a.html

      8.54 Natural gas ( = 0.0044 slugs/ft3 and = 5.2x10-5 ft2/s) is pumped through a horizontal 6-in-diameter cast-iron pipe at a rate of 800 lbf/hr. If the pressure at section (1) is 50 psi(abs), determine the pressure at section (2) 8 mi downstream if the flow is assumed incompressible. Is the incompressible assumption reasonable? Explain.

      psi flow rate calculator


    • [DOCX File]Irrigation Water Conveyance (ft) - Home | NRCS

      https://info.5y1.org/psi-to-flow-rate-formula_1_c284f3.html

      Flow measuring appurtenances such as flow meters or weirs, or other means (e.g., number of turns of a gate valve) should be used to determine the rate of flow into the pipeline system. This information shall be provided to the operator, and shall be incorporated …

      flow rate psi chart


    • [DOCX File]Tables - Rochester Institute of Technology

      https://info.5y1.org/psi-to-flow-rate-formula_1_869930.html

      The following graph compares CFD results from two different spike profiles. The response of mass flow rate and outlet pressure is plotted against throttle position. Perfectly linear modulation would result in a linear line extending from minimum flow rate at 0% throttle position to maximum flow rate …

      flow rates psi gpm calculator


    • [DOC File]Flow in Pipes

      https://info.5y1.org/psi-to-flow-rate-formula_1_d4277c.html

      Flow - Branch 4.0 5.0 6.0 7.0 8.0 12.0 15.0 16.0 22.0 32.7 49.0 57.0 67.0 Male/ Female Adapter 1.0 1.5 2.0 2.8 3.5 4.5 5.5 6.5 9.0 14 Friction Loss in Pipes . Example. 1) A watering tank is located 3000' from a pump and pressure tank. A flow rate of 5 gpm is required at the watering tank, and a pressure loss of 10 psi is acceptable.

      flow rates psi gpm chart


    • [DOC File]CALCULATION EXAMPLE

      https://info.5y1.org/psi-to-flow-rate-formula_1_f947d3.html

      The valve flow coefficient (CV) is used as an indicator of the pressure drop across a valve under specific flow conditions and is formally defined as the number of gallons per minute of room temperature water that will flow through the valve with a pressure drop of 1 psi across the valve (see equation [5]).

      pipe flow rates psi gpm


    • [DOC File]FORMULA SHEET - Homestead

      https://info.5y1.org/psi-to-flow-rate-formula_1_691754.html

      Mathematically the flow coefficient can be expressed as: where: Cv = Flow coefficient or flow capacity rating of valve. F = Rate of flow (US gallons per minute). SG = Specific gravity. of fluid (Water = 1). ΔP = Pressure drop across valve (psi). F=CV/square root (SG/delta P) Cv coefficient of flow is a constant.

      water flow calculator with psi


    • [DOC File]CEA- Review Sheet 3

      https://info.5y1.org/psi-to-flow-rate-formula_1_e3b1f0.html

      The water supply system must adequately serve all customers including residential, commercial, and industrial facilities. The water pressure, flow rate, and demand times may vary significantly among users. For residential consumers, the minimum desirable distribution pressure is 40 psi. A pressure over 60 psi is considered high.

      flow rate psi


    • [DOCX File]Energy Efficient Steam Systems

      https://info.5y1.org/psi-to-flow-rate-formula_1_543087.html

      If 100 psig steam were condensed in a heat exchanger, the mass flow rate of steam required to transfer 1,000,000Btu/hr of heat would be about: Msteam = Q / hfg = 1,000,000 Btu/hr / 881 Btu/lb = 1,135 lb/hr. If the temperature of hot water dropped by 100 F as it passed through a heat exchanger, the mass flow rate of water to transfer the same ...

      calculate flow rate from psi


    • [DOCX File]Dr Jorge Ibarra

      https://info.5y1.org/psi-to-flow-rate-formula_1_3840b0.html

      Assuming that the pipe diameter is 4 cm, find the maximum and average velocities in the pipe as well as the volume flow rate. The pressure drop needed to force water through a horizontal1-in.-diameter pipe is 0.60 psi for every 12-ft length of pipe.