Round manual dampers

    • Section 15820 - Dampers

      Round dampers with integral airflow monitor. Round dampers with integral airflow monitor complete with ventilation controller. RELATED SECTIONS ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. Section 10200 – Louvers. Section 15810 - Ducts. Section 15900 - HVAC Instrumentation and Controls.

      round manual balancing damper


    • [DOC File]SECTION 233313-CONTROL DAMPERS

      https://info.5y1.org/round-manual-dampers_1_ead9a1.html

      Round manual balancing dampers suitable for application in HVAC systems with velocities to 1,500 feet per minute (7.7 m/s). SUMMARY. Section 233100 – HVAC Ducts and Casings (Previously 15810). Section 230913.13 – Actuators and Operators (Previously 15900). SUBMITTALS.

      round balancing damper


    • [DOC File]United Enertech

      https://info.5y1.org/round-manual-dampers_1_eaa2d5.html

      Cycle dampers to full open and full closed positions to insure functionality prior to installation. 3.2 INSTALLATION. A. Install dampers at locations indicated n the drawings and in accordance with manufacturer’s instructions. Install dampers round and free from racking. Do not stretch or compress damper frame or sleeve into the opening or duct.

      manual air dampers


    • [DOC File]SECTION 15820 - DUCT ACCESSORIES

      https://info.5y1.org/round-manual-dampers_1_c9926c.html

      MANUAL BALANCING DAMPERS. GENERAL. SECTION INCLUDES. Round, remote cable operated balancing dampers suitable for application in HVAC systems with velocities to 1,500 fpm (7.7 m/s). SUMMARY. Section 233100 – HVAC Ducts and Casings (Previously 15810). Section 230913.13 – Actuators and Operators (Previously 15900). REFERENCES

      manual volume damper hardware


    • [DOC File]Dampers - Fire and Smoke

      https://info.5y1.org/round-manual-dampers_1_7545be.html

      Dampers shall be installed so that the centerline of the damper depth or thickness is located in the centerline of the wall, partition or floor slab depth or thickness. Unless otherwise indicated, the installation details given in SMACNA Fire, Smoke, and Radiation Damper Installation Guide for HVAC and in manufacturer's instructions for fire ...

      round duct dampers


    • Section 15820 - Dampers

      Round manual balancing dampers with integral airflow monitor. RELATED SECTIONS ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. Section 10200 – Louvers. Section 15810 - Ducts. Section 15900 - HVAC Instrumentation and Controls.

      round volume damper