Shgc glazing
[DOC File]SECTION 08620
https://info.5y1.org/shgc-glazing_1_ad3d78.html
Opal (7 wall); VT=42%, SHGC=0.54, U-factor=0.26. Opal IR (3 wall); VT=24%, SHGC=0.37, U=-factor=0.36. Glazing Gaskets: Manufacturer’s proprietary pressure-glazing gaskets of elastomer type and hardness selected by skylight manufacturer to comply with requirements. Glazing gaskets to be extruded Thermoplastic Elastomer by the skylight ...
[DOCX File]Section 08 80 00 - Glazing
https://info.5y1.org/shgc-glazing_1_7e20c5.html
SPEC WRITER NOTE: Insert performance values for selected glazing units based upon manufacturer's data. VLT and SHGC of glazing unit will vary depending on frit pattern selected and thickness of components. Consult manufacturer.
[DOCX File]Ballot Title Page
https://info.5y1.org/shgc-glazing_1_9babdd.html
A matrix of center-of-glazing SHGC and VT glazing options specific to the product line shall be created for use in Equation 4-1 and Equation 4-2. This center-of-glazing matrix may include variations in number of glazing layers, glazing types (tints, laminated glass, etc.), and glazing coatings.
[DOC File]SECTION 084513 - STRUCTURED-POLYCARBONATE-PANEL …
https://info.5y1.org/shgc-glazing_1_e88476.html
Solar-Heat-Gain Coefficient (SHGC): Panel assembly shall have an SHGC of no greater than [0.35] as determined according to NFRC 200. Glazing Visible-Light Transmittance (VT) for exterior and interior panel assemblies is significantly affected by glazing color tint, internal grid, and insulation insert in panel assembly.
[DOCX File]NFRC Procedures Template
https://info.5y1.org/shgc-glazing_1_4c5bea.html
A matrix of center-of-glazing SHGC and VT glazing options specific to the product line shall be created for use in Equation 4-1 and Equation 4-2. This center-of-glazing matrix may include variations in number of glazing layers, glazing types (tints, laminated glass, etc.), and glazing coatings.
[DOC File]Area-Weighted Average Solar Heat Gain Coefficient
https://info.5y1.org/shgc-glazing_1_789c57.html
The Weighted-Average SHGC = The sum of all weightings/total window area. Brugger, A. et.al., Measurement of the Solar Heat Gain Coefficient and U Value of Windows with Insect Screens, ASHRAE SE-99-15-04, 1999. Wall. Window. Glazing . Overhang . A=36” B=36” B=56” A=36” Overhang . Window. Glazing . Wall. B=36” A=36” Overhang . Window ...