Interface with the Owner’s Siemens Apogee PPCL Building Automation System. Input power requirements for laboratory control devices shall not exceed 120 VAC. Each lab room shall include a labeled Room Differential Pressure Indicating Gauge to indicate room pressurization relative to the adjacent room or corridor.
[DOC File]SPECIFICATIONS FOR CENTRIFUGAL PUMP AND FAN …
https://info.5y1.org/siemens-apogee-manual_1_24feca.html
The AC drive shall include terminal strip connection to [BACnet] [Johnson Controls Metasys N2] [Siemens Apogee P1] [Modbus] [Lonworks by internal option card]. F. The AC drive shall have an integrated user interface (keypad) to display information, provide status, and allow configuration and local operation of the drive.
[DOCX File]SECTION 15172 - Yaskawa
https://info.5y1.org/siemens-apogee-manual_1_78fa1a.html
Provide BACnet , Modbus/Memobus, Siemens Apogee, Johnson Controls Metasys communication protocols as standard communication protocols as standard, with the ability to configure controller parameters view controller monitors, control I/O, clear faults and view controller status in both drive and bypass modes.
[DOCX File]ipf.msu.edu
https://info.5y1.org/siemens-apogee-manual_1_4aa9a2.html
On-board BACnet or Siemens APOGEE FLN (P1) communication card configured to communicate on the building control system. The proper card to use shall be determined by the Temperature Control Contractor or Owner. ... When a critical application requires a manual bypass, it shall be noted in the specification or on the drawings. When specified and ...
[DOCX File]SECTION 283100 - FIRE DETECTION AND ALARM
https://info.5y1.org/siemens-apogee-manual_1_cbb203.html
Install a complete point addressable and fully programmed fire alarm system to interface through the existing Siemens Building Technologies Apogee Life Safety 3 (ALS3) fire alarm panel with the FireWorks network. Performance of the added system shall meet all performance aspects of the existing Siemens ALS3 system.
[DOC File]Micrel Case Study Outline - Cypress Envirosystems
https://info.5y1.org/siemens-apogee-manual_1_fbfa96.html
The plant staff would like the monitoring data to be tied to their existing Siemens Apogee automation system. Monitoring points are needed on each CDA branch line (18 locations total), distributed across 30,000 sq-ft of manufacturing area. The existing Apogee system has controller and I/O panels around the perimeter walls of the manufacturing area.
[DOC File]SECTION 262923 - VARIABLE-FREQUENCY MOTOR …
https://info.5y1.org/siemens-apogee-manual_1_8e23d4.html
Embedded BAS Protocols for Network Communications: [ASHRAE 135 BACnet] [Echelon LonWorks] [Johnson Metasys N2] Modbus [Siemens P1 APOGEE] ; protocols accessible via the communications ports. LINE CONDITIONING AND FILTERING
23 09 23 - Building Automation System (BAS) for HVAC
Siemens: APOGEE P2 ALN (preferred) or BACnet I/P. Siemens: BACnet I/P. ... SDC indication of such manual override actions shall be provided as feedback status indication points shown on the Drawings, in conjunction with the application programs within the SDC. H/O/A switches remotely located at the SDC controller shall be behind a locked panel ...