    • [DOCX File]Specification for 1-Phase and 3-Phase Multi-Turn Output ...

      https://info.5y1.org/single-phase-motor-starter-switch_1_5d6d52.html

      The starter shall be mechanically and electrically interlocked, suitable for isolating and soft modulating duty. All starters shall be rated appropriately for the respective motor size. The controls supply transformer shall be fed from two of the incoming three phases or one phase for single phase actuators and must incorporate overload protection.

      single phase manual motor starter


    • [DOC File]Motor Starters to 600 V - Newfoundland and Labrador

      https://info.5y1.org/single-phase-motor-starter-switch_1_96043c.html

      Manual Motor Starters. Single and Three phase manual motor starters of size, type, rating, and enclosure type as indicated, with components as follows: Switching mechanism, quick make and break. One and Three overload heaters, as indicated, manual reset, trip indicating handle. Accessories: Toggle switch or pushbutton: heavy duty labelled as ...

      manual motor switch with overloads


    • [DOC File]PSG Section 16481 - Eaton

      https://info.5y1.org/single-phase-motor-starter-switch_1_27e4f3.html

      MAnual Motor Control. Single-Phase Manual Starters . Manual single-phase starters 1 hp or smaller shall be Cutler-Hammer type MS starters or approved equal. The starter shall have a quick-make/quick-break toggle mechanism. The overload shall have a field adjustment allowing up to +/- 10% variance in ratings of the nominal heater value

      1.5 hp motor starter


    • [DOCX File]SECTION 26 29 13

      https://info.5y1.org/single-phase-motor-starter-switch_1_ee5d50.html

      Thermal element type manual motor starters for single phase motors shall be Westinghouse Type MS. Provide flush mounted units in finished areas and surface mounted units in unfinished areas. Starter shall have NEMA I general purpose enclosure, unless otherwise indicated, and be rated for the motor horsepower required.

      3 phase motor starter switch


    • [DOCX File]SECTION 26 29 00 - DOA Home

      https://info.5y1.org/single-phase-motor-starter-switch_1_e6d9e1.html

      MANUAL MOTOR STARTERS. Single-phase Manual Motor . Controller. s: Provide controllers for motor loads under 1/2 HP. Controllers shall be 4-inch square box cover units with ON/OFF switch and fuse protection for small motor circuits. Fuses shall be Edison base time-delay plug fuses. Controllers shall be Bussmann SSY or equal. Three-phase . Manual ...

      manual motor controller switch


    • [DOCX File]Low voltage motor control centers (Freedom) guide spec

      https://info.5y1.org/single-phase-motor-starter-switch_1_8342c6.html

      conveniently operable without removing components or the motor starter. Overload to have (+/-) 24% adjustability, single-phase sensitivity, isolated alarm contact, and manual or automatic reset-- OR --Solid-State Overload Relay C440. Provide a solid-state overload relay for protection of the motors. The relay shall be Eaton C440 or approved equal.

      manual motor switch