Stainless steel disconnect switches 4x
[DOC File]SECTION: GRINDER PUMP UNITS - Environment One
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_cbe348.html
SECTION: GRINDER PUMP STATIONS. 1.0 General. 1.01 GENERAL DESCRIPTION: The . MANUFACTURER. shall furnish complete factory-built and tested grinder pump unit(s), each consisting of a grinder pump core suitably mounted on an integral stand of stainless steel, electrical quick disconnect …
[DOC File]ZM1762
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_aa6325.html
A ____ steel or ____ stainless steel conduit fitting shall be mounted on the outside of the basin wall. Float switches will be suspended from SS float brackets. Weights, located on the float cords, will be …
[DOC File]MV-ACB GUIDE FORM SPECIFICATION - NEPSI
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_3106f7.html
The capacitor bank shall consist of a single compartmentalized enclosure with NEMA 3R (IP64), NEMA 12 (IP65), NEMA 4X (IP66) (specify one, delete the other two) construction that will house all components, including fuses, capacitors, switches …
[DOC File]SECTION 08520 - ALUMINUM WINDOWS
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_ad2696.html
Equipment disconnect switch shall be stainless steel NEMA-4X and also be located within to prevent vandalism or unauthorized use. 2.7.1.4 Provide adequate sized openings to permit removal of existing …
[DOC File]PSG Section 16441A - Eaton
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_b92f43.html
EnviroLine Stainless Steel Safety Switches. Provide 30- to 400-ampere switches as shown on drawings with a NEMA 4X stainless steel enclosure and stainless steel operating mechanism. The enclosure shall be made of ([304] [316] grade stainless steel with a 304 grade stainless steel operating mechanism. Window Switches …
SECTION 262816.11 - SAFETY DISCONNECT SWITCHES
Fuse pullers shall be provided on all NEMA 4X and 12 switches through 200 A. Renewal parts data shall be shown on the inside of the door. ... Other types, where noted, shall be: NEMA 3R rainproof. NEMA 4X watertight corrosion-resistant . 30 A to 200 A – [304 stainless steel] [316 stainless steel] 400 A to 1200 A – [304 stainless steel…
[DOCX File]SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM …
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_85fd35.html
Disconnect switches for motors on cooling tower fans and similar applications shall be furnished with watertight, stainless steel enclosures. Disconnect switches mounted exterior of the building shall be NEMA type 4X stainless steel.
[DOCX File]ELECTRICAL FOR STEAM UTILITY DISTRIBUTION
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_5b1aca.html
Switch Enclosures: Provide disconnect switches with NEMA enclosures 1, 3R, 4X, 7, or 12 as indicated on the Drawings, or in absence thereof, as determined by installer to fulfill the requirements of the environment. NEMA 4X disconnect switch enclosures shall be stainless steel. Heavy Duty Safety Switches:
[DOC File]Visible Blade Disconnect Switches Procurement Specifications
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_63612e.html
Switches, mechanisms and accessory kits shall be zinc-plated steel with RoHS compliant finish. Aluminum lug/line kits shall be provided with each universal disconnect switch. Single-port lugs shall …
[DOC File]PSG Section 26 28 16.13 - Eaton
https://info.5y1.org/stainless-steel-disconnect-switches-4x_1_b52be5.html
EnviroLine Stainless Steel Safety Switches. Provide 30- to 400-ampere switches as shown on drawings with a NEMA 4X stainless steel enclosure and stainless steel operating mechanism. The enclosure shall be made of ([304] [316] grade stainless steel with a 304 grade stainless steel operating mechanism. Window Switches …
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.