Temperature actuated water regulating valve

    • Water Valves

      5.Heat Exchanger: Copper tubes in copper tube or in steel shell, with water-temperature-actuated, water-regulating valve. 6.Minimum Energy Efficiency: Comply with ASHRAE/IESNA 90.1, "Energy Standard for Buildings except Low-Rise Residential Buildings."

      water temperature control valve


    • [DOC File]Surge Tank Specifications - Waterloo Manufacturing

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_f7765a.html

      I.Integral, Water-Cooled Refrigerant Condenser: // Coaxial, counterflow, tube-in-tube // Brazed-plate // type with liquid-line stop valve and head-pressure-actuated, water-regulating valve. SPEC WRITER NOTE: For high-humidity locations (VA HVAC Design Manual), provide E-coated aluminum fins and corrosion-resistant cabinets.

      temperature actuated modulating valve


    • [DOCX File]SECTION 23 81 00 - DECENTRALIZED UNITARY HVAC …

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_f39332.html

      _____" inlet water diaphragm actuated regulating valve with cast iron body and _____ connections. The valve shall be globe-type with proportional control and a spring-opposed diaphragm actuator arranged for 3 - 15 PSIG operating signal. The valve shall be normally open on loss of air. Rated for _____ GPM at _____ PSIG inlet pressure.

      penn water valves


    • Draft - Water Corporation

      Water flow actuated devices shall be tested? Fast Response sprinklers in service for less than 20 yrs ... Pressure regulating valve shall pass a full flow test. ... , Low temperature alarms in dry pipe, preaction and deluge preaction and deluge) valve enclosure passed test? Waterflow alarms passed tests? Main Drain test shall be conducted on ...

      penn water regulating valve


    • [DOCX File]SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_165d99.html

      Three-Way Water Regulating Valves - The environmental control unit shall be provided with a 3-way head pressure actuated regulating valve. The maximum water pressure shall be 150 or 350 psi (1034 or 2413 kPa). High Efficiency Filters: Replace the standard MERV 8 filter with MERV 11 (based on ASHRAE Std. 52.2) disposable filters.

      sterlco temperature control valve


    • [DOC File]Section 23 25 00 - HVAC WATER TREATMENT

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_c55ce0.html

      Condenser: Single-pass, tube-in-tube coaxial type; with seamless, integral-finned, copper tube and steel outer shell with water-regulating valve. Retain paragraph above …

      sterlco 56 t temp regulator


    • [DOC File]Service Company - Fire Protection

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_dd313e.html

      HT cooling water then flows out of the engine and enters the air separator. The function of air separator is to vent air bubbles, steam, gas that might have built-up in the system. H.T. cooling water is regulated by TCV a temperature regulating valve. TCV might recirculated thethe water or return it to the LT.

      johnson controls water regulating valves


    • [DOC File]Liebert Series 300 DT Dual Input UPS GS - Vertiv

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_a6daa9.html

      3. Back pressure regulating valve: Spring loaded, diaphragm actuated type with bronze or steel body, stainless steel trim with capacity to relieve 100 percent of pump flow with an allowable rise in the regulated pressure of 69 kPa (10 psig) above the set point. Set point shall be 103 kPa (15 psig) above system PRV setting. 4.

      temperature regulating valve for cooling


    • [DOCX File]Michigan State University

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_10eccd.html

      If the actuator is being supplied to the Water Corporation as a separate item, the type of actuator shall be as specified in the Annexure. If the actuator is being supplied to the Water Corporation as part of a complete electrically actuated valve, the type of actuator shall be determined by the Contractor to suit the associated valve. Power Supply

      water temperature control valve


    • [DOC File]Data Aire Series DX Units Guide Specifcations

      https://info.5y1.org/temperature-actuated-water-regulating-valve_1_abf0ae.html

      The condenser circuit shall be pre-piped with a head pressure actuated three-way water regulating valve. Design Pressure The Econ-O-Coil/condenser circuit shall be designed for a pressure of [(150 PSI (1034 kPa)) (300 PSI (2069 kPa))].