Trane condenser coil

    • How Do You Clean a Trane Condenser Coil

      Condenser coil will be made of aluminum fins mechanically bonded to seamless copper tubing and shall include integral subcooling circuit. Coils will be factory leak tested at 3.2Mpa under water. If unit will be installed on corrosive environment, aluminum fins will be pre-coated with gold epoxy, with minimum thickness of 8µm, in order to ...

      trane evaporator coil


    • [DOC File]RTAD Heat Recovery Unit Description

      https://info.5y1.org/trane-condenser-coil_1_28cc84.html

      Condenser Coil: Non-ferrous construction consisting of aluminum plate fins mechanically bonded to seamless copper tubes and circuited for subcooling. Condenser coil shall have coil protection screens on to prevent coil damage. Condenser Fans and Motors: Direct-driven propeller type fans with permanently lubricated motors.

      trane condenser coil cleaning


    • [DOC File]SECTION 238100 - DECENTRALIZED UNITARY HVAC …

      https://info.5y1.org/trane-condenser-coil_1_c11bfa.html

      Ensure that the cooling coil is 10-25 Ton VAV Packaged CS RTU Update static pressure to 3.5” wg Add economizer control based the requirements for ASHRAE 90.1 …

      trane condenser coil repair kit


    • [DOC File]Guide specifications FCD-FED-FCU-FEU - Trane

      https://info.5y1.org/trane-condenser-coil_1_a2d371.html

      A coated wire mesh that covers the coil along the sides of the unit. Access Guards and Half Louvers. A coated wire mesh covers the access area under the condenser coils and half louvers cover the condenser coil. Architectural Louvered Panels. Louvered panels cover the complete condensing coil and service area beneath the condenser. Half Louvers

      trane coated evaporator coil


    • [DOC File]VOYG.DOC

      https://info.5y1.org/trane-condenser-coil_1_9a5188.html

      Condenser Coil: Seamless copper-tube, aluminum-fin coil, including subcooling circuit and backseating liquid-line service access valve. Factory pressure test coils, then dehydrate by drawing a vacuum and fill with a holding charge of nitrogen or refrigerant.

      trane evaporator coil replacement


    • [DOCX File]Throughout the Day Exercise: Primary ...

      https://info.5y1.org/trane-condenser-coil_1_eec83d.html

      The DX coil must be intertwined; horizontal split coils are not acceptable. The vendor will be responsible for changing the coil out in the field if a horizontal coil is substituted with or without approved submittals. 2.08 CONDENSER SECTION. A. Provide all aluminum microchannel type coil…

      trane condenser coil failure


Nearby & related entries: