Water cooled condenser design

    • [DOC File]PART 1 - browardschools

      https://info.5y1.org/water-cooled-condenser-design_1_f1599d.html

      Factory assembled and tested packaged water cooled liquid centrifugal and/or screw chiller furnished complete with compressors, compressor motors, condenser, evaporator, interconnecting refrigerant piping, refrigeration accessories, motor starters, microprocessor module control panel including gauges with indicating lights and auxiliary ...

      standard water cooled condensers


    • [DOC File]Guide Specification Smardt water Cooled Chillers

      https://info.5y1.org/water-cooled-condenser-design_1_56ce82.html

      The chiller shall be able to operate in a stable fashion at this condition for at least 8 hours continuously independent of condenser water flow rate or condenser water temperature relief. F Condenser shall be designed to allow for the flow rate to be reduced to 1.5 gpm per ton without entering laminar flow to allow for variable condenser water ...

      water cooled condenser diagram


    • [DOC File]Guide Specification Smardt water Cooled Chillers

      https://info.5y1.org/water-cooled-condenser-design_1_0c9a42.html

      D. Air-Cooled Condenser: 1. Air cooled packaged chillers and controls shall be capable of reliable operation between 32°F and 105° ambient air temperature. 2. Air-cooled condensers coils shall utilize epoxy coated aluminum fins which shall meet ASTM B117 1000hr salt spray test.

      water cooled condenser troubleshooting


    • SECTION 236427 - AIR-COOLED WATER CHILLERS

      The entire chiller package shall have factory mounted VFD. When VFD s cooled by condenser water, piping to and from the VFD shall be factory installed. The variable speed drive must include a harmonic filter that meets IEEE Standard 519-1992. The IEEE Std 519-1992 Filter Includes:

      air cooled condenser design guide


    • [DOC File]Specification – Smardt water Cooled Chillers

      https://info.5y1.org/water-cooled-condenser-design_1_fbcf36.html

      A. Provide a complete water-cooled, TurboCor compressor equipped chiller as specified. Unit shall consist of one or more magnetic bearing, oil-free centrifugal compressors with integrated variable frequency drive, refrigerant evaporator, condenser and operating controls with equipment protection.

      carrier water cooled condenser


    • [DOCX File]SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS

      https://info.5y1.org/water-cooled-condenser-design_1_165d99.html

      I.Integral, Water-Cooled Refrigerant Condenser: // Coaxial, counterflow, tube-in-tube // Brazed-plate // type with liquid-line stop valve and head-pressure-actuated, water-regulating valve. SPEC WRITER NOTE: For high-humidity locations (VA HVAC Design Manual), provide E-coated aluminum fins and corrosion-resistant cabinets.

      water cooled condensers for refrigeration


    • [DOC File]VERTICOOL - United CoolAir

      https://info.5y1.org/water-cooled-condenser-design_1_0d4566.html

      The water / glycol cooled condenser(s) shall be of co-axial counter flow refrigerant design. The condenser(s) shall be selected to maintain low refrigerant operating pressure, while using a minimum quantity of water or glycol mixture. Maximum working pressures shall not exceed recommended 450 psig water side, 450 psig refrigerant side as ...

      water cooled condenser coil


    • [DOCX File]Section 23 64 00 - PACKAGED WATER CHILLERS

      https://info.5y1.org/water-cooled-condenser-design_1_2b92a9.html

      b.Condenser water temperature. c.Entering and leaving chilled water temperature and control set points. d.Automatic lead-lag switch. 3.Safety Functions: Following conditions shall shut down the chiller and require manual reset to start: a.Loss of chilled water flow. b.Loss of condenser water flow (for water-cooled chillers only).

      water cooled condenser