Water cooled condenser design
[DOC File]PART 1 - browardschools
https://info.5y1.org/water-cooled-condenser-design_1_f1599d.html
Factory assembled and tested packaged water cooled liquid centrifugal and/or screw chiller furnished complete with compressors, compressor motors, condenser, evaporator, interconnecting refrigerant piping, refrigeration accessories, motor starters, microprocessor module control panel including gauges with indicating lights and auxiliary ...
[DOC File]Guide Specification Smardt water Cooled Chillers
https://info.5y1.org/water-cooled-condenser-design_1_56ce82.html
The chiller shall be able to operate in a stable fashion at this condition for at least 8 hours continuously independent of condenser water flow rate or condenser water temperature relief. F Condenser shall be designed to allow for the flow rate to be reduced to 1.5 gpm per ton without entering laminar flow to allow for variable condenser water ...
[DOC File]Guide Specification Smardt water Cooled Chillers
https://info.5y1.org/water-cooled-condenser-design_1_0c9a42.html
D. Air-Cooled Condenser: 1. Air cooled packaged chillers and controls shall be capable of reliable operation between 32°F and 105° ambient air temperature. 2. Air-cooled condensers coils shall utilize epoxy coated aluminum fins which shall meet ASTM B117 1000hr salt spray test.
SECTION 236427 - AIR-COOLED WATER CHILLERS
The entire chiller package shall have factory mounted VFD. When VFD s cooled by condenser water, piping to and from the VFD shall be factory installed. The variable speed drive must include a harmonic filter that meets IEEE Standard 519-1992. The IEEE Std 519-1992 Filter Includes:
[DOC File]Specification – Smardt water Cooled Chillers
https://info.5y1.org/water-cooled-condenser-design_1_fbcf36.html
A. Provide a complete water-cooled, TurboCor compressor equipped chiller as specified. Unit shall consist of one or more magnetic bearing, oil-free centrifugal compressors with integrated variable frequency drive, refrigerant evaporator, condenser and operating controls with equipment protection.
[DOCX File]SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS
https://info.5y1.org/water-cooled-condenser-design_1_165d99.html
I.Integral, Water-Cooled Refrigerant Condenser: // Coaxial, counterflow, tube-in-tube // Brazed-plate // type with liquid-line stop valve and head-pressure-actuated, water-regulating valve. SPEC WRITER NOTE: For high-humidity locations (VA HVAC Design Manual), provide E-coated aluminum fins and corrosion-resistant cabinets.
[DOC File]VERTICOOL - United CoolAir
https://info.5y1.org/water-cooled-condenser-design_1_0d4566.html
The water / glycol cooled condenser(s) shall be of co-axial counter flow refrigerant design. The condenser(s) shall be selected to maintain low refrigerant operating pressure, while using a minimum quantity of water or glycol mixture. Maximum working pressures shall not exceed recommended 450 psig water side, 450 psig refrigerant side as ...
[DOCX File]Section 23 64 00 - PACKAGED WATER CHILLERS
https://info.5y1.org/water-cooled-condenser-design_1_2b92a9.html
b.Condenser water temperature. c.Entering and leaving chilled water temperature and control set points. d.Automatic lead-lag switch. 3.Safety Functions: Following conditions shall shut down the chiller and require manual reset to start: a.Loss of chilled water flow. b.Loss of condenser water flow (for water-cooled chillers only).
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.