SECTION 22 33 13 – INSTANTANEOUS ELECTRIC DOMESTIC …
Install [pressure-reducing valve with integral bypass relief valve in water heater cold water inlet piping] [and] [water hammer arrester in water-heater outlet piping]. [Set pressure-reducing valve for outlet pressure of 25 psig (172 kPa)].
[DOC File]Water Heater Replacement in the Weatherization Assistance ...
https://info.5y1.org/water-heater-mixing-valve-kit_1_27c922.html
The appendices to this tool kit contain other useful water heater information. The components of different types of water heaters are illustrated in ... Some anti-scalding devices are incorporated into the shower and faucet mixing valves, and mix in cold water when a threshold temperature is exceeded. ... Temperature/Pressure Relief Valve – A ...
[DOC File]SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES
https://info.5y1.org/water-heater-mixing-valve-kit_1_a541ce.html
Copy "Primary, Thermostatic, Water Mixing Valves" Paragraph below and re-edit for each type of water mixing valve required. If only one type is required, drawing designation may be omitted. Primary, thermostatic, water mixing valves in first paragraph below are available in NPS 3/4 to NPS 3 and maybe in NPS 4 (DN 20 to DN 80 and maybe in DN 100 ...
[DOCX File]Intellihot | Home
https://info.5y1.org/water-heater-mixing-valve-kit_1_6c15e6.html
General: The water heating plant shall have a recovery of _____ GPH, (_____ GPM) at a _____oF temperature rise. Each water heater shall be ETL Listed; ASME Section IV (HLW) coded and stamped and shall incorporate a negative Pressure gas valve on each exchanger capable of full fire operation at of 2.5” WC of Gas pressure.
[DOC File]SECTION 22 33 13 – INSTANTANEOUS ELECTRIC DOMESTIC …
https://info.5y1.org/water-heater-mixing-valve-kit_1_a96182.html
Install [pressure-reducing valve with integral bypass relief valve in water heater cold water inlet piping] [and] [water hammer arrester in water-heater outlet piping], maximum outlet pressure [___ psig (___ kPa)] [as scheduled]. FIELD QUALITY CONTROL. Do not energize water heater until hydrostatic testing of domestic water lines is complete.
[DOC File]Plumbing - MFIA Inc. Consulting Engineers
https://info.5y1.org/water-heater-mixing-valve-kit_1_dea44f.html
A. Adjust flush valves, pressure reducing valves, mixing valves, water heater thermostats, hot water circulating system balancing valves, and similar equipment. B. Remove construction protection, tags and labels and thoroughly clean all plumbing equipment and trim. Scour all fixtures just prior to building acceptance. END OF SECTION
[DOCX File]iSeries Non-Pump
https://info.5y1.org/water-heater-mixing-valve-kit_1_31e02d.html
Each water heater shall incorporate a negative Pressure gas valve on each exchanger. Each unit shall operate with a minimum Combustion Efficiency of 98% at full fire. _______i200, Gen II each with an input of 199,950 BTU, output of 187,000 BTU, 228 GPH, (3.8 GPM) at 40-140 oF when fired with natural gas, turndown ratio 7:1, CO emissions of less ...
SECTION 235216 - CONDENSING BOILERS
This valve shall be controlled by the water heater control system as an element of the integrated water heater management. Each water heater shall include an electric, single-seated combination safety shutoff valve/regulator with proof of closure switch in its gas train.
[DOC File]MONTHLY TEMPERATURE CHECKS OF THE HOT AND COLD …
https://info.5y1.org/water-heater-mixing-valve-kit_1_1dc6b8.html
Monthly temperature checks of the hot and cold water cylinders/tanks. Date Outgoing water temperature from the hot water cylinder ... If a thermostatic mixing valve (TMV) is present, use a surface temperature probe for measuring the temperature at the inlet pipe to the TMV ...