Record the static water supply pressure in psi (bar) as indicated on the lower pressure gauge. Open the main drain and allow water flow to stabilize. Record the residual water supply pressure while water is flowing from the main drain as indicated on the lower pressure gauge in psi (bar).
[DOC File]OPERATION AND MAINTENANCE MANUAL
https://info.5y1.org/water-pressure-test-gauge_1_7a55c6.html
Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall notexceed 1 ½ psi (0.1 bar) in 24 hours. Multiple lines or sections: If more than one line or section is tested, an approved method shall be utilized for control and tracking of completed test locations.
NFPA
Special Procedures for Building Domestic Hot and Cold Water Supply Piping: Upon completion of a section or of the entire system, water test the section or system and prove tight under a pressure not less than 125% of its MAWP or 125 psi (1 550 kPa) gauge, whichever is greater, for a period of 24 hours.
Contractor’s Material and Test Certificate for Fire ...
When the level in the tank falls to 135,000 gallons, a Low Level Pressure Switch will turn the water well pumps on. When the tank level rises to 150,000 gallons, a High Level Pressure Switch will shut the well water pumps down. Treated Water System items checked daily include: Tank level and Chlorine residual in the storage tank.
Contractors Material and Test Certificate for Underground ...
After the first portion of the test is completed, the pump pressure should be raised to 200 psi and the test run for 10 minutes to complete the third portion of the test. The pump pressure should be raised to 250 psi. See examples on the next page. 1000 gpm pump 6 inch suction 20 feet. Pump Pressure GPM Nozzle Tip Discharge Hose Pitot Reading
[DOC File]2 HOUR HIGH PRESSURE LEAKAGE TEST, WATER MAIN …
https://info.5y1.org/water-pressure-test-gauge_1_639923.html
The pressure gauge for water domestic use shall conform to //NSF 61// //and// //NSF 372//. THERMOMETERS Thermometers shall be straight stem, metal case, red liquid-filled thermometer, approximately 175 mm (7 inches) high, 4 degrees C to 100 degrees C (40 degrees F to 212 degrees F).
SECTION 220111.13 - TESTING AND MAINTENANCE OF …
test Reading of gauge located near water. Supply test connection: _____ psi Residual pressure with valve in test connection open wide: _____ psi Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping: Verified by copy of …
[DOC File]PRESSURE TEST RECORD
https://info.5y1.org/water-pressure-test-gauge_1_528250.html
DATE: CONTRACT MANAGER: CONTRACT NO.: INSPECTOR: LOCATION: LINE & GRADE: CONTRACTOR: COMPUTED BY: SIZES & TYPES OF WATER MAIN: CHECKED BY: BOX 1 2 HOUR HIGH PRESSURE TEST High Hydraulic Gradient per contract drawings Minus lowest invert within test section – Total = X .434 Equals the pressure at low point = Lowest Surge Pressure per Standard …
Best Water Pressure Gauge: Reviews in 2021
test fluid: applicable code: test requirements required test pressure: test fluid temperature: required test duration: ambient temperature: gauge pressure calculation (see section 4.2.4) elevation difference between gauge and high point: x conversion factor: plus required test pressure: equals required gauge pressure: test results test date ...
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Hot searches
- international journal of economic papers
- free word document resume templates
- cognitive psychology theories
- cognitive psychology quizlet chapter 8
- is cognitive psychology a science
- conjugate base formula calculator
- louisiana health department physician license
- 101st paratroopers on d day
- operations supervisor duties and responsibilities
- dentist office in florence sc