Weather resistant gfci 20a
[DOC File]AnytimeCE.com - Plumbing, Electrical & HVAC Courses
https://info.5y1.org/weather-resistant-gfci-20a_1_8fc6ec.html
Ground-fault circuit-interrupter type. both of the answers provided. neither of the answers provided. Screws used to attach a receptacle to a box will be of the type provided with a listed receptacle, or part of listed assemblies or systems. True. False. Countertop receptacles shall be listed as _____. AFCI. GFCI. weather-resistant. tamper ...
[DOC File]SECTION 262726 - WIRING DEVICES
https://info.5y1.org/weather-resistant-gfci-20a_1_c3e6fb.html
GFCI Trip: Test for tripping values specified in UL 1436 and UL 943. Using the test plug, verify that the device and its outlet box are securely mounted. The tests shall be diagnostic, indicating damaged conductors, high resistance at the circuit breaker, poor connections, inadequate fault current path, defective devices, or similar problems.
[DOC File]SECTION 26 51 13.13
https://info.5y1.org/weather-resistant-gfci-20a_1_207574.html
12" Modular Track: adorne® Part No. APMT12TM2; 12-inch length includes one (1) outlet module and one (1) blank module; capable of supporting up to two (2) LED lights; provides 120V power via 15A outlet modules and 20A pass-through; module openings on six (6) inch centers; outlets are tamper resistant …
[DOC File]SECTION 26 27 26 - DDS (Distributor Data Solutions)
https://info.5y1.org/weather-resistant-gfci-20a_1_a05cd0.html
20A Specification Grade Self-Test Weather-Resistant GFCI Duplex Receptacles: Part No. 2097TRWR[LA][I][W][--][BK][GRY]; rated 20 amps, 125 volts; nylon face, body, and test/reset buttons; thermoplastic tamper-resistant shutter; terminals accept #14 - #10 AWG solid or stranded copper or copper-clad conductors; SafeLock® Protection performs an ...
[DOCX File]ARCAT, Inc.
https://info.5y1.org/weather-resistant-gfci-20a_1_b67b49.html
Tamper-Resistant Commercial Grade Dual Function AFCI/GFCI Receptacle by Leviton Mfg. Co., Inc.; UL Listed, CSA Certified, colors as selected from manufacturer's standard colors. 15 amp, 125 volt, 20 amp feed through terminals, AGTR1 Series.
[DOC File]SECTION 16140 - Government of New York
https://info.5y1.org/weather-resistant-gfci-20a_1_a5205f.html
Sep 07, 2012 · 2. Duplex receptacle rated 20A (NEMA 5-20R), circuit ampacity 20A; Bryant’s GFR53FT, Crouse-Hind/AH’s GF5342, Hubbell’s GF 5352, Leviton’s 6899, Pass & Seymour’s 2091S, or Daniel Woodheads 5352GF. WEATHER RESISTANT GFCI RECEPTACLES ARE REQUIRED IN ALL WET AND DAMP LOCATIONS. G. Weather Resistant Ground Fault Interrupter Receptacles: 1.
[DOCX File]ARCAT | Free Building Product CAD Details, BIM, Specs and …
https://info.5y1.org/weather-resistant-gfci-20a_1_6d87a7.html
Products: Pass & Seymour, 1595TRWR (15A duplex GFCI weather resistant). Products: Pass & Seymour, 2095TRWR (20A duplex GFCI weather resistant). Tamper-Resistant, Hospital-Grade, Duplex GFCI Convenience Receptacles, 125 V, 15 and 20 A: Comply with UL 498 Supplement SD and Federal Specification W-C-596.