What is a soft return

    • EVALUATION Capacitive Electrosurgical Return Electrodes ...

      May 12, 2020 ·


    • [PDF File]MEGADYNE™ Product Catalog - Johnson & Johnson Medical Devices

      https://info.5y1.org/what-is-a-soft-return_1_1be4fc.html

      a) The Mega Soft™ Universal should be cleaned, rinsed, and dried after use. Megadyne™ has a list of over 40 cleaning/ disinfection solutions approved for use with Mega Soft™ return electrodes, including mild bleach, quaternary ammonium, phenol, and alcohol solutions. Megadyne™ Mega Soft™ Universal Figure 1.


    • [PDF File]Review of Capacitive Return Electrodes Electrosurgery

      https://info.5y1.org/what-is-a-soft-return_1_fc0159.html

      Over Mega Soft’s expected life of two years, the total cost of ownership per Mega Soft Reusable Patient Return Electrode unit is $2,482 and for adhesive electrodes it is $6,614.40 over the same time period. This equates to a $4,132.4 (62%) lower cost for Mega Soft. Beyond product acquisition costs, Mega Soft reduces the


    • [PDF File]Megadyne™ MEGADYNE™ MEGA SOFT™

      https://info.5y1.org/what-is-a-soft-return_1_12bd49.html

      The MEGADYNE™ MEGA SOFT™ combines the MEGA SOFT™ patient return electrode technology with an OR table pressure reduction pad so it can be used in a variety of surgical procedures and positions. The dual-cord option has a patient return electrode with two electrosurgical connectors, which allow one pad to be used with two separate


    • [PDF File]MEGA SOFT™ Return Electrode - Johnson & Johnson Medical Devices

      https://info.5y1.org/what-is-a-soft-return_1_daf648.html

      MEGA SOFT™ Return Electrode and the patient form a capacitor. The patient acts as the top plate of the capacitor. There is a dielectric material in the MEGA SOFTTM Return Electrode pad separating a conductive plate and the patient, forming the capacitor. The nature of capacitance leads to some considerations for clinical use.


    • [PDF File]Measuring Return on Investment (ROI) and Cost Benefit ... - FGDC

      https://info.5y1.org/what-is-a-soft-return_1_db1e01.html

      SOFT™ and MEGA 2000 Reusable Patient Return Electrodes (“Mega Soft pads”) and to bring heightened awareness of the potential for burns and actions you can take which may help mitigate risks related to the Mega Soft pad setup and cleaning process.


    • URGENT FIELD SAFETY NOTICE - BfArM

      MEGA SOFT™ Dual Cord Patient Return Electrode 117 cm (46”) L x 51 cm(20”) W, 1.25 cm (1/2”) thickness 0835 1 MEGA SOFT™ Pediatric Patient Return Electrode 66 cm (26”) L x 30.5 cm (12”) W, 1.3 cm (1/2”) thickness For patients between 0.36 kg (0.8 lbs.) and 22.7 kg (50 lbs.) 0840 1 MEGA 2000™ Reusable Patient Return Electrode