[PDF File]Specification Grade Receptacle Application and Buyer's Guide
https://info.5y1.org/wr-gfi-receptacles_1_6daa0e.html
All outdoor 15A and 20A, 125V receptacles must be GFCI protected (not just those accessible to public). Receptacles cannot be enclosed with other switches or receptacles adjacent that exceed 300V unless there is a barrier. All 15A and 20A, 125V receptacles installed within 6 ft. (1.8m) of sinks need GFCI protection. Exceptions
[PDF File]Ground Fault Products
https://info.5y1.org/wr-gfi-receptacles_1_7211b4.html
All GFCI receptacles listed above are furnished with a matching color nylon wallplate. 20 amp feed-through capability. * See Section X, page X-10 for TR and WR descriptions. 15A 125V NEMA 5-15R 20A 125V NEMA 5-20R 15A 125V NEMA 5-15R 20A 125V NEMA 5-20R Ground Fault Products Heavy Duty Commercial and Hospital Grade Tamper-Resistant GFCI Receptacles
[PDF File]IAEI UL Question Corner Tamper-Resistant and Weather ...
https://info.5y1.org/wr-gfi-receptacles_1_73dfa3.html
words “Weather Resistant” or the letters “WR” where they will be visible after installation with the cover plate secured as intended.” Weather-resistant receptacles are also available as tamper-resistant receptacles. Ground-fault circuit-interrupter (GFCI) receptacles are Listed under the category Ground-Fault Circuit Inter-
[PDF File]Self Test Ground Fault Receptacles
https://info.5y1.org/wr-gfi-receptacles_1_f78d56.html
AUTOGUARD® Self Test Technology 6 www.hubbell-wiring.com Commercial Tamper-Resistant and Weather Resistant GFCI Receptacles Features • Patented shutter design for tamper-resistant protection • Meets NEC requirements for TR (517-18c) and WR (406.9), UV and corrosion resistance for
[PDF File]Eaton's Arrow Hart Ground fault circuit interrupters
https://info.5y1.org/wr-gfi-receptacles_1_19de59.html
receptacles. Tamper resistant (TR) receptacles feature a built-in UL listed safety shutter system that prevents the insertion of foreign objects into the receptacle openings. The safety shutters will only open when a two-bladed plug presses simultaneously against the two shutters. Weather resistant (WR) GFCIs feature corrosion resistant
[PDF File]Extra Heavy-Duty Self-Test GFCI Receptacles
https://info.5y1.org/wr-gfi-receptacles_1_0c92f4.html
Self-Test GFCI Receptacles - Wallplate Not Included Cat. No. Descrip. & Color NEMA 5-15R 15 A-125 V @ Receptacle • 20 A-125 V Feed-Through Non-TR TR WR & TR Pilot Light Isolated Ground Leaded Brown G5262-000 G5262-0T0 G5262-WT GFPL1-PL GFTR1-IG * Ivory G5262-00I G5262-0TI G5262-WTI GFPL1-PLI GFTR1-IGI GFTR1-5LI ‡
[PDF File]Tamper & Weather Resistant Receptacles
https://info.5y1.org/wr-gfi-receptacles_1_b8c710.html
that states that all receptacles installed in wet and damp locations must be weather resistant. •Manufactured with the highest grade of materials; durable impact-resistant thermoplastic face and back body is virtually unbreakable. WR Commercial Grade, Duplex 426 A …
[PDF File]Extra Heavy-Duty Self-Test GFCI Receptacles
https://info.5y1.org/wr-gfi-receptacles_1_183646.html
Self-Test GFCI Receptacles - Matching Wallplate Included Cat. No. Descrip. & Color NEMA 5-15R 15 A-125 V @ Receptacle • 20 A-125 V Feed-Through Non-TR TR WR & TR* Standard NAFTA Standard NAFTA Standard Brown GFNT1-HG GFNT1-HF GFTR1-HG GFTR1-HF GFWT1-HG Ivory GFNT1-HGI GFNT1-HFI GFTR1-HGI GFTR1-HFI GFWT1-HGI
[PDF File]Arrow Hart weather resistant and tamper and weather ...
https://info.5y1.org/wr-gfi-receptacles_1_c005b8.html
tamper & weather resistant receptacles Table 2. WR & TWR specification grade GFCI Table 3. WR & TWR commercial grade receptacle TWR270 TWRSGF20 Rating Catalog no. Description A V/AC NEMA Color suffix WRBR15__ Duplex receptacle 15 125 5-15R B, V, W WRBR20__ Duplex receptacle 20 125 5-20R B, V, W TWRBR15__ Duplex receptacle 15 125 5-15R B, GY, V, W
[PDF File]HOMEOWNER WIRING MANUAL - South Dakota
https://info.5y1.org/wr-gfi-receptacles_1_5bb6e3.html
These receptacles shall be listed a s WR and shall have covers that are weatherproof whether or not an attachment plug is inserted. NEC 210.52(G) – At least one receptacle outlet must be installed for each car space in the garage, this circuit shall not supply outlets outside of the garage.
[PDF File]Testing a GFCI Receptacle
https://info.5y1.org/wr-gfi-receptacles_1_7ab090.html
Resistant (WR). • For installation in wet locations, protect the GFCI receptacle with a weatherproof cover that will keep both the receptacle and any plugs dry. • Must be installed in accordance with national and local electrical codes. CAUTION 2. The GFCI’s features Cable Wires Installing and Testing a GFCI Receptacle Please read this ...
[PDF File]Lutron Tamper Resistant, Self-Testing GFCI Receptacles ...
https://info.5y1.org/wr-gfi-receptacles_1_02527a.html
® GFCI Tamper Resistant, Self-Testing Receptacles 369964a 2 08.13.15 Specifications Regulatory Approvals • Meets UL 943 Class A GFCIs and UL 498 for Receptacles • Complies to NEC, CEC & OSHA, UL File E-41978, CSA File LR-24886 • UL Listed • CSA Certified • NOM Certified • UL 943 Dust Test: Meets performance requirement
Power Pedestals 6 - Elliott Electric
Receptacles and Circuit Protection Circuit protection shall be Eaton’s UL listed full-size ... Available GFI (ground fault interrupter) single- and ... WR WR TR. 294 Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6.2 Power Pedestals Te mporary ...
[PDF File]Outdoor Weatherproof B
https://info.5y1.org/wr-gfi-receptacles_1_a8e511.html
WR 74-C WR104-C One Gang, Single Receptacle Covers–Vertical Mount One Gang, Single Receptacle Covers–Horizontal Mount WR104-CV One Gang Single Receptacle Covers Cat. Std. No. Description Finish Ctn. WR 74-C Cover, stay open lid, opening dia. 1.590 Gray 50 WR104-C Cover, self-closing lid, horizontal mount, Gray 25 opening dia. 1.590
[PDF File]ELECTRICAL PLAN SYMBOLS ELECTRICAL ONE-LINE SYMBOLS ...
https://info.5y1.org/wr-gfi-receptacles_1_e3b6fd.html
gfi ground fault interrupter (breaker) gfci ground fault circuit interrupter (receptacle) grc galvanized steel rigid conduit gen generator g ground / equipment ground / ground fault fwd forward fvr full voltage reversing fvnr full voltage non-reversing fu sw fused switch fu fuse freq frequency frc fiberglass rigid conduit fo fiber optic
[PDF File]Tamper and weather resistant receptacles brochure
https://info.5y1.org/wr-gfi-receptacles_1_edb5ec.html
TR receptacles 4 TR & GFCI receptacles 5 WR & TWR receptacles 6 TR specification and performance data 7 WR & TWR specification and performance data 8-9 Tamper resistant receptacles feature a UL Listed safety shutter system that prevents the insertion of foreign objects into a receptacle. The safety shutters will only
[PDF File]GFCIs and AFCIs D - Leviton
https://info.5y1.org/wr-gfi-receptacles_1_7bdd5b.html
D-4 GFCIs and AFCIs Online catalog available at leviton.com D GFCIs and AFCIs GFCIs and AFCIs TAmper-resIsTAnT And nOn TAmper-resIsTAnT reCepTACles, And devICes GFCI ReCeptACleS | Back and Side Wired X7590-W X7592-W X7899-W Smartlockpro® Slim Series Commercial Spec Grade Back and Side Wired GFCI with Professional Grade Lockout U R Rating 15A–125V @ Receptacle 20A–125V @ Receptacle
[PDF File]GFCI Products Buying Guide - Leviton
https://info.5y1.org/wr-gfi-receptacles_1_82a5a8.html
the WR symbol on the face to ensure it is rated for outdoor use. Outdoor locations such as decks, patios, and pool areas. Portable GFCI Cord Sets & User-Attachable Devices For temporary power equipment that requires GFCI protection, manual or automatic reset portable GFCIs can be used. Automatic reset models immediately provide power to a load
[PDF File]Electrical Code Rules for Portable & Temporary Electrical ...
https://info.5y1.org/wr-gfi-receptacles_1_e9f005.html
Receptacles protected from the weather must have an enclosure that is weatherproof with the receptacle covers closed (in-use cover). An outlet box hood (cover) installed for this purpose must be listed and identified as “extra duty.” All 15- and 20-ampere, 125- and 250-volt receptacles used outdoors must be listed as weather-resistant (WR).
[PDF File]NEMA Plug & Receptacle Configurations
https://info.5y1.org/wr-gfi-receptacles_1_b92c77.html
receptacles NEMA x5 - 15P P indicates plug or receptacle P is plug R is receptacle or socket 15 indicates the current rating and standard values are 15 amps 20 amps 30 amps 5 indicates the voltage* 2 indicates 115 VAC, ungrounded for Class II connections 5 indicates 125 VAC, grounded for Class I connections 6 indicates 250 VAC, grounded for ...
[PDF File]PASS & SEYMOUR Specification Grade Self-Test GFCIs 15 ...
https://info.5y1.org/wr-gfi-receptacles_1_86fc69.html
Specification Grade Self-Test GFCI Receptacles 1597TR* TradeMaster/Spec Grade Tamper-Resistant 15 Amp Duplex GFCI 15A 125V I, W, –, BK, LA, NI, AB, DB 5-15R 1597* TradeMaster/Spec Grade 15 Amp Duplex GFCI 15A 125V I, W, –, GRY, BK, RED, LA 5-15R 1597TRA* TradeMaster Audible Alarm Tamper-Resistant Duplex GFCI 15A 125V I, W, –, BK LA 5-15R
[PDF File]Arrow Hart weather resistant and tamper and weather ...
https://info.5y1.org/wr-gfi-receptacles_1_c005b8.html
tamper & weather resistant receptacles Table 2. WR & TWR specification grade GFCI Table 3. WR & TWR commercial grade receptacle TWR270 TWRSGF20 Rating Catalog no. Description A V/AC NEMA Color suffix WRBR15__ Duplex receptacle 15 125 5-15R B, V, W WRBR20__ Duplex receptacle 20 125 5-20R B, V, W TWRBR15__ Duplex receptacle 15 125 5-15R B, GY, V, W
[PDF File]SECTION 16000 - Electrical Part 1 - General 1.1 Scope of ...
https://info.5y1.org/wr-gfi-receptacles_1_8ea25c.html
When required for classrooms, receptacles for overhead LCD projector shall be mounted flush in finished ceiling. F. Wet and Damp Locations: 20 Amp, 125 Volt and 250 Volt non-locking receptacles in wet or damp locations shall be ‘Weather-Resistant’, GFI receptacles with ‘WR’ clearly marked on face. G.
[PDF File]GFCI (Ground Fault Circuit Interrupter) Devices
https://info.5y1.org/wr-gfi-receptacles_1_fcc657.html
Weather-Resistant GFCI (WR) receptacles, which meet UL 498 requirements. Built with UV stabilized engineering thermoplastic, the devices have high cold impact resistance and feature stainless steel straps and mounting screws. Leviton SmartlockPro icon ensures improved GFCI product design. Lockout action blocks the
[PDF File]RESIDENTIAL GARAGE WIRING - Saint Paul, Minnesota
https://info.5y1.org/wr-gfi-receptacles_1_41b788.html
receptacles are designed with a “shutter” over the slots so only a standard cord cap (plug) can be inserted. Add-on plug covers are not acceptable. Any receptacles on the exterior of the garage must be tamper-resistant, GFCI-protected and “weather resistant” (there will be a “WR” visible on the face of the receptacle) .
SECTION 26 00 20 ELECTRICAL MATERIALS AND METHODS PART 1 ...
GFI Receptacles: Ground fault interrupter receptacles shall be feed-through type capable of protecting connected downstream receptacles on . Standard Specifications Electrical Materials and Methods Revised Jan 2017 26 00 20-5 single circuit, ivory, grounding type, UL rated Class A, Group 1, 20 ampere rating, 125 V with solid state ground fault ...