150 kva transformer size
[DOCX File]SECTION 16460 DRY-TYPE TRANSFORMERS
https://info.5y1.org/150-kva-transformer-size_1_76536a.html
Minimum Linear Load Efficiency: NEMA TP-1 and EPA ENERGY STAR compliant; 97.5 percent for 30 kVA, 97.7 percent for 45kVA, 98.0 percent for 75 kVA, 98.2 percent for 112.5kVA, 98.3 percent for 150 kVA, 98.5 percent for 225 kVA, 98.6 percent for 300 kVA, 98.7 percent for 500 kVA.
[DOC File]Functional Specification for Single-Phase Pad-Mounted Type …
https://info.5y1.org/150-kva-transformer-size_1_476e39.html
The transformer shall be designed in accordance with this specification and shall have one of the following kVA ratings: 5, 10, 15, 25, 37.5, 50, 75, 100, 167. The applicable kVA rating shall be specified on the inquiry. Table 1. Transformer and Connector High-Voltage Ratings and Electrical Characteristics for dead-front transformers
[DOC File]BASIC NEC CODE RULES AND DESIGN PRACTICE
https://info.5y1.org/150-kva-transformer-size_1_7ba407.html
KW = KVA, P.F. = 1.0 KVA = 15. Wire Size. Wire Size = Load = ampacity = 65.2 Amp = 81.5 Amp.8 ... 150 1/0 120. 175 2/0 140. 200 3/0 160 . 225 4/0 180 ... All the buildings served by a common transformer must be reevaluate to insure that the. existing short circuit protection is adequate for the larger transformer required when additional ...
[DOC File]PART 1 – GENERAL
https://info.5y1.org/150-kva-transformer-size_1_10f5f0.html
3 Submit certified type test results for linear load efficiency from 35 to 65% load for each size of transformer ordered on the project for approval before shipment. ... < 0.95% and 0.3% for up to 150 kVA, < 1.0% and 0.5% for 225 kVA and 300 kVA, < 1.5% and 1.0% for 500kVA..4 Load compatibility: K factor up to 20, Crest factor up to 4.5 ...
[DOCX File]Section 26 12 19, Pad-Mounted, Liquid-Filled, Medium …
https://info.5y1.org/150-kva-transformer-size_1_55c927.html
D.Transformer impedance shall be not less than 4-1/2% for sizes 150 kVA and larger. Impedance shall be as shown on the drawings. E.Sound levels shall conform to …
[DOC File]Typical Specification, ULLTRA type L
https://info.5y1.org/150-kva-transformer-size_1_9d28a9.html
[Select the below text if specifying Low Load Range Transformer] 15 kVA: 50 watts, 30 kVA: 90 watts, 45 kVA: 120 watts, 75 kVA: 170 watts, 112.5kVA: 250 watts, 150 kVA: 310 watts, 225 kVA: 430 watts, 300 kVA: 530 watts . Submit for approval before shipment certified type test results for maximum no load losses for each size of transformer ...
[DOC File]PS202002EN - Eaton
https://info.5y1.org/150-kva-transformer-size_1_8d1995.html
(available from 13 amps up to 900 amps of full-load transformer current, up to 34.5 kV, grounded wye or delta, maximum 150 KV BIL) The high-voltage or low-voltage overcurrent protection scheme provided with the transformer shall be an integral Vacuum Fault Interrupter (VFI).