208 230 3 phase disconnect
[DOCX File]Section 08731 - Automatic Door Operators - Commercial
https://5y1.org/info/208-230-3-phase-disconnect_1_525788.html
1.Electric Operator: Industrial-duty assembly, cULus listed and cULus labeled, complete with electric motor and factory-prewired motor controls, internal auxiliary reversal circuit, 3-button open/close/stop control station, conduit-encased wiring from control circuit to motor, and accessories required for proper operation; operator shall be capable of driving door at a speed of approximately 8 ...
[DOC File]Crawford Door Sales Co
https://5y1.org/info/208-230-3-phase-disconnect_1_e45021.html
Incoming electrical shall be (Choose One): 120VAC single phase, 208VAC single phase, 208/230VAC 3-phase, 480VAC 3-phase. Control panel assemblies shall be UL listed as per NFPA70. Controls shall include a programmable logic controller with digital message display or LED indicators.
[DOCX File]Section 08731 - Automatic Door Operators - Commercial
https://5y1.org/info/208-230-3-phase-disconnect_1_41f972.html
Electric Operator: Industrial-duty assembly, cULus listed and cULus labeled, complete with electric motor and factory-prewired motor controls, positive locking mechanical system acting as a holding brake, emergency disconnect for manual operation of the door, 3-button open/close/stop control station, conduit-encased wiring from control circuit to motor, and accessories required for proper ...
[DOC File]T24H-T60H Series Engineering Specification Guide - Word
https://5y1.org/info/208-230-3-phase-disconnect_1_c0d21f.html
Circuit breaker is standard on all 208/230-volt models and rotary disconnect standard on all 460-volt models. Circuit breaker/rotary disconnect access is through lockable access panel. Phase rotation monitors shall be installed on all 3-phase units to prevent reverse rotation. 2.9 CONTROL CIRCUIT
[DOC File]REVISED: 1/95
https://5y1.org/info/208-230-3-phase-disconnect_1_238c18.html
Disconnect the two wires from the two-pin hermetic terminal in the compressor housing. 2. Remove the module mounting screws and remove the module and connecting wires. ... 230/208 3-Phase. 460 3-Phase. 575 3-Phase. MOTOR PROTECTION SYSTEM. Modules have a 4-minute delay upon interruption of L1-L2 supply or after any fault condition occurs.
[DOCX File]Section 08731 - Automatic Door Operators - Commercial
https://5y1.org/info/208-230-3-phase-disconnect_1_2600b4.html
For single-phase applications, incoming voltage field-selectable between 115V and 230V, 60 Hz by properly positioning connector. For 3-phase applications, incoming voltage field-selectable between 208V, 230V and 460V, 60 Hz by properly positioning connector.
[DOCX File]CED Template
https://5y1.org/info/208-230-3-phase-disconnect_1_27e487.html
Tri-voltage 208/230/460V 3 phase multi-tap transformer. Interlock system to prevent operation when doors are open and to ensure proper operational sequencing. Moving parts are shielded or enclosed during operations.
[DOCX File]SECTION 23 34 23.08 – PROPELLER FANS
https://5y1.org/info/208-230-3-phase-disconnect_1_40a20d.html
Voltage: [208] [230] [460] [575] V; [1] [3] phase; 60 Hz. Specifier: If factory disconnect is required, select NEMA enclosure rating in following paragraph, and select one …
[DOC File]TYM 1300_1700 Gate System - Tymetal
https://5y1.org/info/208-230-3-phase-disconnect_1_c0c2e3.html
Jan 03, 2015 · 208/230 VAC single phase and 208/230/460 VAC three phase available. 115 is not available. (50 Hertz is available specify voltage.) FACTORY TESTING: Fully assemble and test, at the factory, each gate operator to assure smooth operation, sequencing and electrical connection integrity. Apply physical loads to the operator to simulate field conditions.
[DOC File]WG3S-WG5S Series Step Capacity Gas/Electric Specification ...
https://5y1.org/info/208-230-3-phase-disconnect_1_3fd780.html
Circuit breaker is standard on 208/230-volt models both single phase and three phase. 460/3/60 volt models shall have rotary disconnect. Circuit breaker or disconnect access is through lockable access panel. 2.9 CONTROL CIRCUIT The internal control circuit shall consist of a current limiting 24VAC type 50VA transformer with 208/230 primary taps.