240 vac plugs
[DOC File]Manual
https://info.5y1.org/240-vac-plugs_1_6f1531.html
If you must use an extension cable, use a three-wire cable with properly grounded plugs. ... The internal universal power supply operates with 100-240 VAC at frequency of 50-60 Hz. A back panel power module includes a fuse block that is configured for two fuses. Each fuse is a 5 x 20 mm, 1 Amp slow blow fuse. ...
[DOCX File]Industrial Fans, Ceiling Fans & More | Big Ass Fans
https://info.5y1.org/240-vac-plugs_1_323ae1.html
The fan motor shall be a 2/3 hp electronically commutated motor with electrical input of 110–120 VAC, 50/60 Hz, 1 Φ or 200–240 VAC, 50/60 Hz, 1 Φ. The motor shall be rated IP65 for washdown cleaning.
[DOC File]UPGRADE INFORMATION - Catalina 30
https://info.5y1.org/240-vac-plugs_1_455cc8.html
The present 120 VAC US panel is white, and the 240 VAC EURO is pewter gray. Both panels have black engraving. PANELS FOR C-27 THROUGH C-36. AC-DC CONTROL PANEL - White w/ black engraving, 19 x 8.5, 19 circuits. NOT backlit, using rectangular ROCKER switches in 1 x 1/2" holes, combined with push-to-reset CIRCUIT BREAKERS.
[DOC File]NEMA Plug and Receptacle Descriptions - Rennlist
https://info.5y1.org/240-vac-plugs_1_3e200f.html
The first number represents the voltage: 5 = 120 VAC 6 = 208/240 VAC. The second number represents the current: for example 15 = 15 Amps
[DOCX File]GENERAL
https://info.5y1.org/240-vac-plugs_1_47da61.html
When space heaters are required, and storage of the equipment is planned, provide terminal points accessible for connection of temporary [120] [240] VAC control power. Plenum Arc gases shall be vented using internal flap systems and plenum duct to direct gases outside of the enclosure.
[DOCX File]ELECTRIC ROOF, GUTTER & DOWNSPOUT
https://info.5y1.org/240-vac-plugs_1_31471a.html
A.The heating cable shall be 120 VAC or 240 VAC rated (240 VAC cable may be operated safely at 208 VAC, 240 VAC, or 277 VAC). Cable heaters must not be pre-terminated with plugs. Cables heaters must include a 10 year warranty (minimum).
[DOCX File]Busway - LV guide spec - Eaton
https://info.5y1.org/240-vac-plugs_1_b6d1a7.html
It shall be possible to increase the interrupting rating of a breaker plug-in device having ampere ratings through 400 Amp up to 100 kAIC at 480 VAC and 200 kAIC at 240 VAC by changing out the circuit breaker only and leaving the enclosure intact. All breaker plug-in devices shall be from the same manufacturer as the busway.
[DOCX File]Low voltage circuit breakers guide spec - Eaton
https://info.5y1.org/240-vac-plugs_1_b68133.html
Electrically operated breakers shall be complete with [close/open pushbuttons] [control switch], plus red and green indicating lights to indicate breaker contact position [24 Vdc] [48 Vdc] [120 Vac/125 Vdc] [240 Vac/250 Vdc] [208-277 Vac] motor operators; the charging time of the motor shall not exceed 6 seconds.
[DOCX File]Introduction - Colorado Department of Transportation
https://info.5y1.org/240-vac-plugs_1_0679a9.html
Verify voltage in sign load center is within +/- 10% of 120 VAC or 240 VAC. Verify sign and cabinet are properly grounded. Verify that after power cycling all equipment turns back on properly.
SECTION 255011 - ENERGY MONITORING AND CONTROL …
Power relays external to the FPU, switching 240 VAC maximum; shall be base mounted, 20 Amps, contacts and coil voltage as indicated on the drawings, Westinghouse, Allen Bradley, Square D, or equal. Review coil VA requirements and increase size of FPU 24 VAC transformer and circuit breaker if needed.