ࡱ> o Ibjbj 1zfzfY"Y"Y"Y"Y"m"m"m"8"4%m"H'((((*02GGGGGGG$8JL8GY"3**33GY"Y"((HHL<<<3Y"(Y"(F<3G<<K>C(2`7CFNH<HC&Ng9Z&NC&NY"C33<33333GG:Z333H3333&N333333333 !: Copyright 2017 by The American Institute of Architects (AIA) Exclusively published and distributed by AVITRU, LLC for the AIA This Product MasterSpec Section is licensed by AVITRU, LLC to Oatey ("Licensee"). This Product MasterSpec Section modifies the original MasterSpec text and does not include the full content of the original MasterSpec Section. Revisions made to the original MasterSpec text are made solely by the Licensee and are not endorsed by, or representative of the opinions of, Avitru or The American Institute of Architects (AIA). Neither AIA nor Avitru are liable in any way for such revisions or for the use of this Product MasterSpec Section by any end user. A qualified design professional should review and edit the document to suit project requirements. For more information, contact Oatey, 20600 Emerald Pkwy, Cleveland, OH 44135; Phone: (216) 267-7100; Website:  HYPERLINK "http://www.oatey.com" www.oatey.com; Email:  HYPERLINK "mailto:info@oatey.com" info@oatey.com. For information about MasterSpec, contact Avitru at (800) 424-5080 or visit  HYPERLINK "http://www.avitru.com" www.avitru.com. SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES TIPS: To view non-printing Editor's Notes that provide guidance for editing, click on MasterWorks/Single-File Formatting/Toggle/Editor's Notes. To read detailed research, technical information about products and materials, and coordination checklists, click on MasterWorks/Supporting Information. Revise this Section by deleting and inserting text to meet Project-specific requirements. Verify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed. GENERAL RELATED DOCUMENTS Retain or delete this article in all Sections of Project Manual. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division01 Specification Sections, apply to this Section. SUMMARY Section Includes: Vacuum breakers. Backflow preventers. Water pressure-reducing valves. Automatic water shutoff valves. Balancing valves. Temperature-actuated, water mixing valves. Strainers. Outlet boxes. Hose stations. Hose bibbs. Wall hydrants. Ground hydrants. Post hydrants. Drain valves. Water-hammer arresters. Air vents. Trap-seal primer valves. Trap-seal primer systems. Flexible connectors. Water meters. Related Requirements: Retain subparagraphs below to cross-reference requirements Contractor might expect to find in this Section but are specified in other Sections. Section220519 "Meters and Gauges for Plumbing Piping" for thermometers, pressure gauges, and flow meters in domestic water piping. Section221116 "Domestic Water Piping" for water meters. Section223200 "Domestic Water Filtration Equipment" for water filters in domestic water piping. Section224300 "Medical Plumbing Fixtures" for thermostatic mixing valves for sitz baths, thermostatic mixing-valve assemblies for hydrotherapy equipment, and outlet boxes for dialysis equipment. Section224500 "Emergency Plumbing Fixtures" for water tempering equipment. Section224713 "Drinking Fountains" for water filters for water coolers. Section224716 "Pressure Water Coolers" for water filters for water coolers. Section224723 "Remote Water Coolers" for water filters for water coolers. ACTION SUBMITTALS For submittal documents for Oatey products, see  HYPERLINK "http://www.oatey.com" www.oatey.com. Product Data: For each type of product. Retain "Shop Drawings" Paragraph below if retaining "Trap-Seal Primer Systems" Article. Shop Drawings: For domestic water piping specialties. Include diagrams for power, signal, and control wiring. Sustainable Design Submittals: "Product Data" Subparagraph below applies to LEED 2009, LEEDv4, IgCC, and Green Globes for fixtures and equipment that consume water. Product Data: For water consumption. INFORMATIONAL SUBMITTALS Field quality-control reports. CLOSEOUT SUBMITTALS Operation and Maintenance Data: For domestic water piping specialties to include in emergency, operation, and maintenance manuals. PRODUCTS Manufacturers and products listed in SpecAgent and MasterWorks Paragraph Builder are neither recommended nor endorsed by the AIA or Avitru. Before inserting names, verify that manufacturers and products listed there comply with requirements retained or revised in descriptions and are both available and suitable for the intended applications. For definitions of terms and requirements for Contractor's product selection, see Section016000 "Product Requirements." GENERAL REQUIREMENTS FOR PIPING SPECIALTIES Retain both options in first paragraph below if plastic piping specialties are required. Potable-water piping and components shall comply with NSF61[and NSF14].[Mark "NSF-pw" on plastic piping components.] Comply with NSF372 for low lead. PERFORMANCE REQUIREMENTS Coordinate this article with Section221116 "Domestic Water Piping." Minimum Working Pressure for Domestic Water Piping Specialties: [125 psig (860 kPa)] unless otherwise indicated. VACUUM BREAKERS Copy "Pipe-Applied, Atmospheric-Type Vacuum Breakers" Paragraph below and re-edit for each type of vacuum breaker required. If only one type is required, drawing designation may be omitted. Pipe-applied, atmospheric-type vacuum breakers in first paragraph below are for moderate to high hazard and are available in NPS1/4 to NPS3 (DN8 to DN80). They are unsuitable for continuous pressure or for protection from backflow. Pipe-Applied, Atmospheric-Type Vacuum Breakers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Ames Fire & Waterworks; a WATTS brand. Apollo Flow Controls; Conbraco Industries, Inc. Cash Acme, a Division of Reliance Worldwide Corporation. FEBCO; a WATTS brand. . Standard: ASSE1001. Size: NPS1/4 to NPS3 (DN8 to DN80), as required to match connected piping. Body: Bronze. Inlet and Outlet Connections: Threaded. Finish: [Rough bronze] [Chrome plated]. Copy "Hose-Connection Vacuum Breakers" Paragraph below and re-edit for each type of vacuum breaker required. If only one type is required, drawing designation may be omitted. Hose-connection vacuum breakers in first paragraph below are for low hazard and are unsuitable for continuous pressure. Outlet size is garden-hose thread. Hose-Connection Vacuum Breakers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Apollo Flow Controls; Conbraco Industries, Inc. Arrowhead Brass Products. Cash Acme, a Division of Reliance Worldwide Corporation. Legend Valve & Fitting, Inc. MIFAB, Inc. Prier Products, Inc. . Standard: ASSE1011. Body: Bronze, nonremovable, with manual drain. Outlet Connection: Garden-hose threaded complying with ASMEB1.20.7. Finish: [Chrome or nickel plated] [Rough bronze]. Copy "Pressure Vacuum Breakers" Paragraph below and re-edit for each type of vacuum breaker required. If only one type is required, drawing designation may be omitted. Pressure vacuum breakers in first paragraph below are for moderate to high hazard and are available in NPS1/2 to NPS2 (DN15 to DN50). Pressure Vacuum Breakers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Ames Fire & Waterworks; a WATTS brand. Apollo Flow Controls; Conbraco Industries, Inc. FEBCO; a WATTS brand. Flomatic Corporation. . Standard: ASSE1020. Operation: Continuous-pressure applications. Pressure Loss: [5 (35)] psig (kPa) maximum, through middle third of flow range. Size: . Design Flow Rate: . Selected Unit Flow Range Limits: . Pressure Loss at Design Flow Rate: . Accessories: Valves: Ball type, on inlet and outlet. Copy "Laboratory-Faucet Vacuum Breakers" Paragraph below and re-edit for each type of vacuum breaker required. If only one type is required, drawing designation may be omitted. Laboratory-faucet vacuum breakers in first paragraph below are for moderate to low hazard and are available in NPS1/4 and NPS3/8 (DN8 and DN10). Laboratory-Faucet Vacuum Breakers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Apollo Flow Controls; Conbraco Industries, Inc. . Standard: ASSE1035. Size: NPS1/4 or NPS3/8 (DN8 or DN10) matching faucet size. Body: Bronze. End Connections: Threaded. Finish: Chrome plated. Copy "Spill-Resistant Vacuum Breakers" Paragraph below and re-edit for each type of vacuum breaker required. If only one type is required, drawing designation may be omitted. Spill-resistant vacuum breakers in paragraph below are for high hazard and are available in NPS1/4 to NPS1 (DN8 to DN25). Spill-Resistant Vacuum Breakers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Apollo Flow Controls; Conbraco Industries, Inc. . Standard: ASSE1056. Operation: Continuous-pressure applications. Size: [NPS1/4 (DN8)] [NPS3/8 (DN10)] [NPS1/2 (DN15)] [NPS3/4 (DN20)] [NPS1 (DN25)]. Accessories: Valves: Ball type, on inlet and outlet. BACKFLOW PREVENTERS Copy "Intermediate Atmospheric-Vent Backflow Preventers" Paragraph below and re-edit for each type of backflow preventer required. If only one type is required, drawing designation may be omitted. Intermediate atmospheric-vent backflow preventers in first paragraph below are for moderate hazard and are available in NPS1/2 and NPS3/4 (DN15 and DN20). Intermediate Atmospheric-Vent Backflow Preventers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Apollo Flow Controls; Conbraco Industries, Inc. Cash Acme, a division of Reliance Worldwide Corporation. FEBCO; a WATTS brand. Honeywell. Legend Valve & Fitting, Inc. . Standard: ASSE1012. Operation: Continuous-pressure applications. Size: [NPS1/2 (DN15)] [NPS3/4 (DN20)]. Body: Bronze. End Connections: [Union, solder] [Solder] joint. Finish: [Chrome plated] [Rough bronze]. Copy "Reduced-Pressure-Principle Backflow Preventers" Paragraph below and re-edit for each type of backflow preventer required. If only one type is required, drawing designation may be omitted. Reduced-pressure-principle backflow preventers in first paragraph below are for high hazard and are available in NPS3/4 to NPS10 (DN20 to DN250). Reduced-Pressure-Principle Backflow Preventers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Ames Fire & Waterworks; a WATTS brand. Apollo Flow Controls; Conbraco Industries, Inc. FEBCO; a WATTS brand. Flomatic Corporation. . Standard: ASSE1013. Operation: Continuous-pressure applications. Pressure Loss: [12 psig (83 kPa)] maximum, through middle third of flow range. Size: . Design Flow Rate: . Selected Unit Flow Range Limits: . Pressure Loss at Design Flow Rate: for sizes NPS2 (DN50) and smaller; for NPS2-1/2 (DN65) and larger. Body: Bronze for NPS2 (DN50) and smaller; [cast iron with interior lining that complies with AWWAC550 or that is FDA approved] [steel with interior lining that complies with AWWAC550 or that is FDA approved] [stainless steel] for NPS2-1/2 (DN65) and larger. End Connections: Threaded for NPS2 (DN50) and smaller; [flanged] for NPS2-1/2 (DN65) and larger. Configuration: Designed for [horizontal, straight-through] [vertical-inlet, horizontal-center-section, and vertical-outlet] [vertical] flow. Accessories: Valves NPS2 (DN50) and Smaller: Ball type with threaded ends on inlet and outlet. Valves NPS2-1/2 (DN65) and Larger: Outside-screw and yoke-gate type with flanged ends on inlet and outlet. Air-Gap Fitting: ASMEA112.1.2, matching backflow-preventer connection. Copy "Double-Check, Backflow-Prevention Assemblies" Paragraph below and re-edit for each type of backflow-prevention assembly required. If only one type is required, drawing designation may be omitted. Double-check, backflow-prevention assemblies in first paragraph below are for low hazard and are available in NPS3/4 to NPS10 (DN20 to DN250). Double-Check, Backflow-Prevention Assemblies : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Ames Fire & Waterworks; a WATTS brand. Apollo Flow Controls; Conbraco Industries, Inc. FEBCO; a WATTS brand. Flomatic Corporation. . Standard: ASSE1015. Operation: Continuous-pressure applications unless otherwise indicated. Pressure Loss: [5 psig (35 kPa)] maximum, through middle third of flow range. Size: . Design Flow Rate: . Selected Unit Flow Range Limits: . Pressure Loss at Design Flow Rate: for sizes NPS2 (DN50) and smaller; for NPS2-1/2 (DN65) and larger. Body: Bronze for NPS2 (DN50) and smaller; [cast iron with interior lining that complies with AWWAC550 or that is FDA approved] [steel with interior lining that complies with AWWAC550 or that is FDA approved] [stainless steel] for NPS2-1/2 (DN65) and larger. End Connections: Threaded for NPS2 (DN50) and smaller; [flanged] for NPS2-1/2 (DN65) and larger. Configuration: Designed for [horizontal, straight-through] flow. Accessories: Valves NPS2 (DN50) and Smaller: Ball type with threaded ends on inlet and outlet. Valves NPS2-1/2 (DN65) and Larger: Outside-screw and yoke-gate type with flanged ends on inlet and outlet. Copy "Beverage-Dispensing-Equipment Backflow Preventers" Paragraph below and re-edit for each type of backflow preventer required. If only one type is required, drawing designation may be omitted. Beverage-dispensing-equipment backflow preventers in first paragraph below are for moderate hazard and are available in NPS1/4 and NPS3/8 (DN8 and DN10). Beverage-Dispensing-Equipment Backflow Preventers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Apollo Flow Controls; Conbraco Industries, Inc. . Standard: ASSE1022. Operation: Continuous-pressure applications. Size: NPS1/4 or NPS3/8 (DN8 or DN10). Body: Stainless steel. End Connections: Threaded. Copy "Dual-Check-Valve Backflow Preventers" Paragraph below and re-edit for each type of backflow preventer required. If only one type is required, drawing designation may be omitted. Dual-check-valve backflow preventers in first paragraph below are for low hazard and are available in NPS1/2 to NPS1-1/4 (DN15 to DN32). Dual-Check-Valve Backflow Preventers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: A.Y. McDonald Mfg. Co. Apollo Flow Controls; Conbraco Industries, Inc. Cash Acme, a division of Reliance Worldwide Corporation. FEBCO; a WATTS brand. Flomatic Corporation. Ford Meter Box Company, Inc. (The). Honeywell. Legend Valve & Fitting, Inc. Mueller Co. . Standard: ASSE1024. Operation: Continuous-pressure applications. Size: [NPS1/2 (DN15)] [NPS3/4 (DN20)] [NPS1 (DN25)] [NPS1-1/4 (DN32)]. Body: Bronze with union inlet. Copy "Carbonated-Beverage-Dispenser, Dual-Check-Valve Backflow Preventers" Paragraph below and re-edit for each type of backflow preventer required. If only one type is required, drawing designation may be omitted. Carbonated-beverage-dispenser, dual-check-valve backflow preventers in first paragraph below are for moderate hazard and are available in NPS1/4 and NPS3/8 (DN8 and DN10). Carbonated-Beverage-Dispenser, Dual-Check-Valve Backflow Preventers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Cash Acme, a division of Reliance Worldwide Corporation. Lancer Corporation. . Standard: ASSE1032. Operation: Continuous-pressure applications. Size: NPS1/4 or NPS3/8 (DN8 or DN10). Body: Stainless steel. End Connections: Threaded. Copy "Reduced-Pressure-Detector, Fire-Protection, Backflow-Preventer Assemblies" Paragraph below and re-edit for each type of backflow-preventer assembly required. If only one type is required, drawing designation may be omitted. Reduced-pressure-detector, fire-protection, backflow-preventer assemblies in first paragraph below are for high hazard and are available in NPS3 to NPS10 (DN80 to DN250). Reduced-Pressure-Detector, Fire-Protection, Backflow-Preventer Assemblies : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Ames Fire & Waterworks; a WATTS brand. Apollo Flow Controls; Conbraco Industries, Inc. FEBCO; a WATTS brand. . Standard: ASSE1047 and is FM Global approved or UL listed. Operation: Continuous-pressure applications. Pressure Loss: [12 psig (83 kPa)] maximum, through middle third of flow range. Size: . Design Flow Rate: . Selected Unit Flow Range Limits: . Pressure Loss at Design Flow Rate: . Body: [Cast iron with interior lining that complies with AWWAC550 or that is FDA approved] [Steel with interior lining that complies with AWWAC550 or that is FDA approved] [Stainless steel]. End Connections: Flanged. Configuration: Designed for [horizontal, straight-through] [vertical-inlet, horizontal-center-section, and vertical-outlet] [vertical] flow. Accessories: Valves: Outside-screw and yoke-gate type with flanged ends on inlet and outlet. Air-Gap Fitting: ASMEA112.1.2, matching backflow-preventer connection. Bypass: With displacement-type water meter, shutoff valves, and reduced-pressure backflow preventer. Copy "Double-Check, Detector-Assembly Backflow Preventers" Paragraph below and re-edit for each type of backflow preventer required. If only one type is required, drawing designation may be omitted. Double-check, detector-assembly backflow preventers in first paragraph below are for low hazard and are available in NPS3 to NPS10 (DN80 to DN250). Double-Check, Detector-Assembly Backflow Preventers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Ames Fire & Waterworks; a WATTS brand. Apollo Flow Controls; Conbraco Industries, Inc. FEBCO; a WATTS brand. . Standard: ASSE1048 and is FM Global approved or UL listed. Operation: Continuous-pressure applications. Pressure Loss: [5 psig (35 kPa)] maximum, through middle third of flow range. Size: . Design Flow Rate: . Selected Unit Flow Range Limits: . Pressure Loss at Design Flow Rate: . Body: [Cast iron with interior lining that complies with AWWAC550 or that is FDA approved] [Steel with interior lining that complies with AWWAC550 or that is FDA approved] [Stainless steel]. End Connections: Flanged. Configuration: Designed for [horizontal, straight-through] [vertical-inlet, horizontal-center-section, and vertical-outlet] [vertical] flow. Accessories: Valves: Outside-screw and yoke-gate type with flanged ends on inlet and outlet. Bypass: With displacement-type water meter, shutoff valves, and reduced-pressure backflow preventer. Copy "Hose-Connection Backflow Preventers" Paragraph below and re-edit for each type of backflow preventer required. If only one type is required, drawing designation may be omitted. Hose-connection backflow preventers in first paragraph below are for high hazard. Outlet size is garden-hose thread. Caution: Availability is limited. Hose-Connection Backflow Preventers : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Apollo Flow Controls; Conbraco Industries, Inc. . Standard: ASSE1052. Operation: Up to 10-foot head of water (30-kPa) back pressure. Inlet Size: NPS1/2 or NPS3/4 (DN15 or DN20). Outlet Size: Garden-hose thread complying with ASMEB1.20.7. Capacity: At least 3-gpm (0.19-L/s) flow. Copy "Backflow-Preventer Test Kits" Paragraph below and re-edit for each type of test kit required. If only one type is required, drawing designation may be omitted. Backflow-preventer test kits in paragraph below are suitable for pressure vacuum breakers; reduced-pressure-principle backflow preventers; double-check, backflow-prevention assemblies; and double-check, detector-assembly backflow preventers. Backflow-Preventer Test Kits : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Apollo Flow Controls; Conbraco Industries, Inc. FEBCO; a WATTS brand. Flomatic Corporation. . Description: Factory calibrated, with gages, fittings, hoses, and carrying case with test-procedure instructions. WATER PRESSURE-REDUCING VALVES Copy "Water Regulators" Paragraph below and re-edit for each type of water regulator required. If only one type is required, drawing designation may be omitted. Water regulators in first paragraph below are available in NPS1/2 to NPS3 (DN15 to DN80). Water Regulators : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Apollo Flow Controls; Conbraco Industries, Inc. Cash Acme, a division of Reliance Worldwide Corporation. Honeywell. . Standard: ASSE1003. Pressure Rating: Initial working pressure of 150 psig (1035 kPa). Size: . Design Flow Rate: . Design Inlet Pressure: . Design Outlet Pressure Setting: . Body: Bronze[with chrome-plated finish] for NPS2 (DN50) and smaller; cast iron[with interior lining that complies with AWWAC550 or that is FDA approved] for NPS2-1/2 and NPS3 (DN65 and DN80). Valves for Booster Heater Water Supply: Include integral bypass. End Connections: Threaded for NPS2 (DN50) and smaller; flanged for NPS2-1/2 and NPS3 (DN65 and DN80). Copy "Water-Control Valves" Paragraph below and re-edit for each type of water-control valve required. If only one type is required, drawing designation may be omitted. Water-control valves in paragraph below are available in NPS1-1/4 (DN32) and larger. Water-Control Valves : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: American Standard. Apollo Flow Controls; Conbraco Industries, Inc. CLA-VAL Automatic Control Valves. Flomatic Corporation. OCV Control Valves. . Description: Pilot-operated, diaphragm-type, single-seated, main water-control valve. Pressure Rating: Initial working pressure of 150 psig (1035 kPa) minimum with AWWAC550 or FDA-approved, interior epoxy coating. Include small pilot-control valve, restrictor device, specialty fittings, and sensor piping. Main Valve Body: Cast- or ductile-iron body with AWWAC550 or FDA-approved, interior epoxy coating; or stainless-steel body. Size: . Pattern: [Angle] [Globe]-valve design. Trim: Stainless steel. Design Flow: . Design Inlet Pressure: . Design Outlet Pressure Setting: . End Connections: Threaded for NPS2 (DN50) and smaller; [flanged] for NPS2-1/2 (DN65) and larger. AUTOMATIC WATER SHUTOFF VALVES Domestic water automatic shutoff valves below are generally available in NPS3/4 to NPS4 (DN20 to DN100); verify sizes with manufacturer. Automatic water shutoff valves are most commonly installed in domestic water piping, although they can be used for other applications where moisture detection is desired. Systems include remote water leak sensors to actuate the shutoff valve upon sensing water or possibly temperature. Some systems use a pipe-mounted flow sensor to detect unusual water flow. Variations of the valve are available for water mains, and domestic appliances (clothes washers, domestic water heaters, ice makers, sump pumps, clean rooms, and HVAC system condensate pans). Multiple wired water leak sensors connected to a system allow for wider area coverage. Wireless water leak sensors allow more sensor connections than wired sensors. Relay contacts are used for secondary signaling, device control, and audible alarms. Retain "Manufacturers" Paragraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: DynaQuip Controls. FloLogic, Inc. OnSite PRO Inc. . Standards: NSF61 and NSF372. Retain "Shutoff Control Ball Valve" Paragraph below for ball valve sizes NPS3/4 through NPS2 (DN15 through DN50). Copy "Shutoff Control Ball Valve" Paragraph and re-edit for each type of shutoff control ball valve required. If only one type is required, drawing designation may be omitted. Shutoff Control Ball Valve : Size: [NPS1/2 (DN15)] [NPS3/4 (DN20)] [NPS1 (DN25)] [NPS1-1/4 (DN32)] [NPS1-1/2 (DN40)] [NPS2 (DN50)] . Design Flow Rate: . Design Inlet Pressure: . Control Valve: Two-piece, full-port brass ball valve, MSSSP-110. End Connections: Threaded, female. Seats: PTFE. O-Rings: FKM. Stem: Low lead brass. Blowout proof. CWP Rating: [600 psig (4140 kPa)] . Manual override control turn-knob for emergency operation of the valve. Retain "Shutoff Control Butterfly Valve" Paragraph below for butterfly valve sizes NPS2-1/2 through NPS4 (DN65 through DN100). Copy "Shutoff Control Butterfly Valve" Paragraph and re-edit for each type of shutoff control butterfly valve required. If only one type is required, drawing designation may be omitted. Shutoff Control Butterfly Valve : Size: [NPS2-1/2 (DN65)] [NPS3 (DN80)] [NPS4 (DN100)] . Compliance: MSSSP-67. Full-port, epoxy-coated, ductile-iron lug body. Seat: EPDM, minus 30 degF to plus 250 degF (minus 34 degC to plus 121 degC). Face-to-Face Flange: ASMEB16.5 flanges. Disc Design: Floating stainless steel dual shaft. Disc Material: [Iron nylon11] [Stainless steel]. Locating Pin: Carbon steel. Bushings: PTFE. O-Rings: EPDM. Ten-position stop. Manual override control turn-knob for emergency operation of the valve. Retain "Clothes Washer Shutoff Control Valve" Paragraph below for control valves for clothes washers, shutting off both hot- and cold-water supplies. Copy "Clothes Washer Shutoff Control Valve" Paragraph and re-edit for each type of shutoff control valve required. If only one type is required, drawing designation may be omitted. Clothes Washer Shutoff Control Valve : Two-way, four-port, low-zinc bronze alloy valve. End Connections: Male hose connections, NPS3/4 (DN20). Pressure Rating: 400 psi (2758 kPa) at 32 to 150 degF (0to 65.6 degC). Maximum Test Pressure: 1200 psig (8274 kPa). Stem Travel: 0.16 inch (4.0 mm). Maximum Temperature: 250 degF (121 degC). Valve Stem: Burnished Type303 stainless steel. Valve Stem Packing: Double EPDM. Valve Seat: Integral bronze. Valve Disc and Plunger: EPDM. Valve Spring: Stainless steel. Hoses: Two, 9-inch (229-mm) steel braided. Hose End Connections: One straight and one 90-degree elbow connection; both hoses. Retain "Clothes Washer Shutoff Control Valve Actuator" Paragraph below for control valve actuators for clothes washers, shutting off both hot- and cold-water supplies. Clothes Washer Shutoff Control Valve Actuator: Two position, drive closed, spring open. Housing: High-temperature composite glass-filled nylon. Connection to Valve: NPT female brass ring. Electric Motor: Reversible, brushless, and synchronism, maintains constant control speed to keep the cycle time constant. Maximum stem output is force balance controlled with electronic shutoff when end travel is detected in both directions. Maximum Working Force: 48 lbf (213N). Power Requirements: Input Voltage: 24V ac. Frequency: [60] [50] Hz. Current: [0.045] A. Power: [1] VA. Power Supply: 120-to 24-V ac transformer[with cord and plug]. Working Time: [90] seconds. Duty Rating: 100 percent. Travel: 0.16 inch (4.0 mm). Position Indicator: Standard. Working Temperature: 40 to 120 degF (4.4 to 48.9 degC). Conform to CE and ROHS requirements. Retain "Water Main Shutoff Valve Actuator" Paragraph below for ball and butterfly shutoff valves. Water Main Shutoff Valve Actuator: Motor operated, with or without gears, electric and electronic. Capable of closing valve against inlet pressure. Direct mount, two way; fails open/open or closed/closed. Actuator Torque: [133 in. x lbf (15N xm)] [266 in. x lbf (30N xm)] . Power Requirements: Input Voltage: [12] [24]V dc. Frequency: [60] [50] Hz. Current: [2] A. Power: [15] [24] VA. Power Supply: 120-V ac to [12] [24]-V dc transformer[with cord and plug]. Working Time: [8] [10] seconds. Torque Limiter: STD. Duty Rating: [50] [75] percent. Protection: [IP65] [IP67]. Rotation: [90] [180] degrees. Manual Intervention: Allowed. Position Indicator: Standard. Working Temperature: Minus 4 degF to plus 131 degF (Minus 20 degC to plus 55 degC). Retain "Domestic Water Heater Shutoff Valve Actuator" Paragraph below for domestic water heater shutoff valve actuators. Domestic Water Heater Shutoff Valve Actuator: Motor operated, with or without gears, electric and electronic. Capable of closing valve against inlet pressure. Direct mount, two way; fails open/open or close/close. Power Requirements: Input Voltage: 24V ac. Frequency: [60] [50] Hz. Current: [0.6] A. Power: [15] VA. Power Supply: 120-V ac to 24-V ac transformer[with cord and plug]. Working Time: [45] seconds. Rotation: 90 degrees. Manual Intervention: Allowed. Position Indicator: LED for closed position. Working Temperature: 0to 100 degF (Minus 17.8 to plus 37.8 degC). Audible Alarm: [83] dB. Retain "Actuator Enclosure" Paragraph below for actuator enclosures. Actuator Enclosure: Suitable for ambient conditions encountered by application. NEMA250, Type2 for indoor and protected applications. Material: Self-extinguishing class techno-polymer. . Retain "Wireless Leak Detection Receiver System" Paragraph below for wireless sensors and coordinate with wired sensor options. Wireless Leak Detection Receiver System: Onboard Battery Backup: 48 hours of protection.[Valve to close prior to backup failure.] LED Indicators: Wireless signal strength, communication loss, water fault, low temperature fault, and low battery. Output Contacts: Interface with home security or building automation system, cellular text notification service, or auto dialer accessories. Retain "FCC-Approved Wireless Communication System" Subparagraph below for systems with this capability. FCC-Approved Wireless Communication System: Between devices; sensors, repeaters, and receivers. Proprietary 900-MHz wireless communication platform ensures system operation without Wi-Fi dependence or other communication platforms, subject to power and random service outages. Automatic wireless communication testing and positive confirmation ensure that system devices remain active and working correctly. Automatic fault notification for lost communication or missing device. Power Supply: [120V ac] [9-V dc battery]. Wireless system can accommodate up to 80 individual sensors; verify with manufacturer. Dual Function Wireless Sensors: [2] .[Valve closes if temperature falls below 45 degF (7.2 degC)]. Specific range may vary due to local structural conditions. Wireless Signal Range: 100 feet (30.5m) between sensors and receiver. Custom range finding feature. LED Indicators: Wireless signal strength, communication loss, water fault, low temperature, and low battery. Self-monitoring enabled system; faults for lost communication between receiver and sensor(s). Closed-Loop RF System: System remains active even when power and Wi-Fi signals are lost. Retain "Wired Leak Detection System" Paragraph below for wired sensors and coordinate with wireless sensor options. Wired Leak Detection System: Local water sensor. Power Supply: ClassII transformer with cord and plug, 120V ac, UL listed. Power Cord Length: [12 feet (3.66m)] . Control Panel: LED power and LED valves indicator. Alarms: Audible alarm[,with external output]. Wired Sensors: Quantity Per Receiver: [One] [Two] [Three] [Four] [Five] [Six]. Cable Length: [8 feet (2.44m)] [25 feet (7.62m)] [50 feet (15.2m)] [100 feet (30.5m)] . Retain "Sensor Elevation" Subparagraph below if overflow detection is required, such as HVAC system condensate pans. Sensor Elevation: Elevated [1/2 inch (13 mm)] above condensate drain pan. Accessories: Water Flow Sensors: Pipe-mounted to detect water flow. Rope Sensor: Absorbent water sensing rope constructed from twisted metal conductor wires insulated from one another and surrounded by polyethylene mesh braid jacket. Connect up to 100 feet (30.5m) (10 sections) of sensor rope to a single receiver. Retain one of first three subparagraphs below for power-vented gas water heaters, requiring that electricity to the power-venter also be shut off when a water leak is detected. Electrical Plug Interrupter: Plugs into standard 120-V ac wall outlet. Gas Flow Interrupter: ECO connector with female spade connectors. Factory prewired, 8 feet (2.44m). Gas Interface Cable: Interface cable with male and female connectors. Step-Down Transformer: [120] [208] [240]V ac to 24V ac with mounting plate, 12-foot (3.66-m) plenum wire to power, and 8-foot (2.44-m) plenum wire to sensor. Liquid Level Sensors: Monitor fluid levels in addition to detecting plumbing leaks. In first subparagraph below, "Auto Dialer" requires a dedicated analog phone line. Auto Dialer: Send and receive automatic alerts when a fault condition occurs. Standard output contacts trigger up to nine predetermined telephone number calls. Prerecord message for future playback. 10-second recordable message. Built-in tamper switch. DC adaptor with battery backup. Programmable as a silent (dialer only) or audible (siren and dialer) alarm. Easy "Stop Call Sequence" - push "#" on phone to acknowledge the alarm and stop the dialing sequence. In first subparagraph below, "Cellular Text Notification System" requires a mobile wireless network service provider. Cellular Text Notification System. Event SMS text notification to up to three cell phones. Battery Backup: Four (4) AA batteries. 12-foot (3.66-m) interface cable to leak detection system. Customized messaging. . "Cable Adder" Subparagraph below is for installations that require an additional distance between receiver and shutoff valve. Cable Adder: [10 feet (3m)] [25 feet (7.62m)] [50 feet (15.2m)] [100 feet (30.5m)] in length. Subparagraphs below are wireless accessories. Wireless Signal Repeater: Boosts signal performance between wireless sensors and receiver. Push-button pairing and unpairing, into and out of the network. Visual indication of wireless signal strength, low battery, and lost communication. Standard wall outlet, 120V ac, power. Battery Backup: Two (2) AA batteries to maintain system integrity during a power outage. Wireless Water Switch: Allows manual override or wireless system functionality and closes the valve to shut off water flow. Hard-Wired Water Switch: Allows manual override or wireless system functionality and closes the valve to shut off water flow. BALANCING VALVES Copy "Copper-Alloy Calibrated Balancing Valves" Paragraph below and re-edit for each type of balancing valve required. If only one type is required, drawing designation may be omitted. Copper-Alloy Calibrated Balancing Valves : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Armstrong International, Inc. Flo Fab Inc. ITT Corporation. NIBCO INC. . Type: [Ball] [or] [Y-pattern globe] valve with two readout ports and memory-setting indicator. Body: [Brass] [or] [bronze]. Size: Same as connected piping, but not larger than NPS2 (DN50). Accessories: Meter hoses, fittings, valves, differential pressure meter, and carrying case. Copy "Cast-Iron Calibrated Balancing Valves" Paragraph below and re-edit for each type of balancing valve required. If only one type is required, drawing designation may be omitted. Cast-Iron Calibrated Balancing Valves : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Armstrong International, Inc. Flo Fab Inc. ITT Corporation. NIBCO INC. . Type: Adjustable with Y-pattern globe valve, two readout ports, and memory-setting indicator. Size: Same as connected piping, but not smaller than NPS2-1/2 (DN65). Accessories: Meter hoses, fittings, valves, differential pressure meter, and carrying case. Copy "Memory-Stop Balancing Valves" Paragraph below and re-edit for each type of balancing valve required. If only one type is required, drawing designation may be omitted. Memory-Stop Balancing Valves : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Apollo Flow Controls; Conbraco Industries, Inc. Crane; Crane Energy Flow Solutions. Hammond Valve. Jenkins Valves; Crane Energy Flow Solutions. Milwaukee Valve Company. NIBCO INC. . Standard: MSSSP-110 for two-piece, copper-alloy ball valves. Pressure Rating: 400-psig (2760-kPa) minimum CWP. Size: NPS2 (DN50) or smaller. Body: Copper alloy. Port: Standard or full port. Ball: Chrome-plated brass. Seats and Seals: Replaceable. End Connections: Solder joint or threaded. Handle: Vinyl-covered steel with memory-setting device. TEMPERATURE-ACTUATED, WATER MIXING VALVES Copy "Water-Temperature Limiting Devices" Paragraph below and re-edit for each type of limiting device required. If only one type is required, drawing designation may be omitted. Water-temperature limiting devices in first paragraph below are unsuitable for service as master thermostatic mixing valves. Devices below are available in NPS1/2 to NPS1 (DN15 to DN25) and comply with ASSE1016, ASSE1017, or both; however, neither standard is adequate for them. ASSE1070, "Performance Requirements for Water Temperature Limiting Devices," is under development. Water-Temperature Limiting Devices : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Apollo Flow Controls; Conbraco Industries, Inc. Armstrong International, Inc. Cash Acme; a division of Reliance Worldwide Corporation. Honeywell. Legend Valve & Fitting, Inc. Leonard Valve Company. POWERS; a WATTS brand. . Standard: ASSE1017. Pressure Rating: 125 psig (860 kPa). Type: Thermostatically controlled, water mixing valve. Material: Bronze body with corrosion-resistant interior components. Connections: Threaded[union] inlets and outlet. Accessories: Check stops on hot- and cold-water supplies, and adjustable, temperature-control handle. Tempered-Water Setting: . Retain "Tempered-Water Design Flow Rate" Subparagraph below only if flow rate is not indicated on Drawings. Tempered-Water Design Flow Rate: . Valve Finish: [Chrome plated] [Rough bronze]. Copy "Primary, Thermostatic, Water Mixing Valves" Paragraph below and re-edit for each type of water mixing valve required. If only one type is required, drawing designation may be omitted. Primary, thermostatic, water mixing valves in first paragraph below are available in NPS3/4 to NPS3 and maybe in NPS4 (DN20 to DN80 and maybe in DN100), but usually are NPS2 (DN50) or smaller. Primary, Thermostatic, Water Mixing Valves : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Acorn Engineering Company. Apollo Flow Controls; Conbraco Industries, Inc. Armstrong International, Inc. Cash Acme, a division of Reliance Worldwide Corporation. Lawler Manufacturing Company, Inc. Leonard Valve Company. POWERS; a WATTS brand. . Standard: ASSE1017. Pressure Rating: 125 psig (860 kPa) minimum unless otherwise indicated. Type: [Exposed-mounted] [Cabinet-type], thermostatically controlled, water mixing valve. Material: Bronze body with corrosion-resistant interior components. Connections: Threaded[union] inlets and outlet. Accessories: Manual temperature control, check stops on hot- and cold-water supplies, and adjustable, temperature-control handle. Tempered-Water Setting: . Retain "Tempered-Water Design Flow Rate" Subparagraph below only if flow rate is not indicated on Drawings. Tempered-Water Design Flow Rate: . Selected Valve Flow Rate at 45-psig (310-kPa) Pressure Drop: . Pressure Drop at Design Flow Rate: . Valve Finish: [Chrome plated] [Polished, chrome plated] [Rough bronze]. Piping Finish: [Chrome plated] [Copper]. Retain "Cabinet" Subparagraph below if cabinet is required. Cabinet: Factory fabricated, stainless steel, for [recessed] [surface] mounting and with hinged, stainless steel door. Copy "Manifold, Thermostatic, Water Mixing-Valve Assemblies" Paragraph below and re-edit for each type of water mixing-valve assembly required. If only one type is required, drawing designation may be omitted. Several manufacturers of thermostatic mixing valves promote single "high-low" valves to be used instead of the manifold valve assemblies in first paragraph below. If single valves are required for high and low systems, specify them in "Primary, Thermostatic, Water Mixing Valves" Paragraph. Manifold, Thermostatic, Water Mixing-Valve Assemblies : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Leonard Valve Company. POWERS; a WATTS brand. . Description: Factory-fabricated, [cabinet-type] [exposed-mounted], thermostatically controlled, water mixing-valve assembly in [two] [three]-valve parallel arrangement. Large-Flow Parallel: Thermostatic, water mixing valve and downstream-pressure regulator with pressure gages on inlet and outlet. Retain "Intermediate-Flow Parallel" Subparagraph below for three-valve assemblies. Intermediate-Flow Parallel: Thermostatic, water mixing valve and downstream-pressure regulator with pressure gages on inlet and outlet. Small-Flow Parallel: Thermostatic, water mixing valve. Thermostatic Mixing Valves: Comply with ASSE1017. Include check stops on hot- and cold-water inlets and shutoff valve on outlet. Water Regulator(s): Comply with ASSE1003. Include pressure gage on inlet and outlet. Pressure Rating: 125 psig (860 kPa) minimum unless otherwise indicated. Retain "Cabinet" Subparagraph below for cabinet-type assembly. Cabinet: Factory fabricated, stainless steel, for [recessed] [surface] mounting and with hinged, stainless-steel door. Selected Large-Flow, Tempered-Water Valve Size: . Tempered-Water Setting: . Unit Tempered-Water Design Flow Rate: . Unit Minimum Tempered-Water Design Flow Rate: . Selected Unit Flow Rate at 45-psig (310-kPa) Pressure Drop: . Unit Pressure Drop at Design Flow Rate: . Unit Tempered-Water Outlet Size: end connection. Unit Hot- and Cold-Water Inlet Size: end connections. Thermostatic Mixing Valve and Water Regulator Finish: [Chrome plated] [Polished, chrome plated] [Rough bronze]. Piping Finish: [Chrome plated] [Copper]. Copy "Photographic-Process, Thermostatic, Water Mixing-Valve Assemblies" Paragraph below and re-edit for each type of water mixing-valve assembly required. If only one type is required, drawing designation may be omitted. Photographic-Process, Thermostatic, Water Mixing-Valve Assemblies : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Lawler Manufacturing Company, Inc. Leonard Valve Company. POWERS; a WATTS brand. . Standard: ASSE1017, thermostatically controlled, water mixing valve made for precise, process-water temperature control. Pressure Rating: 125 psig (860 kPa) minimum unless otherwise indicated. Body: Bronze with corrosion-resistant interior components. Connections: Threaded inlets and outlet. Accessories: Manual temperature control, check stops on hot- and cold-water supplies, thermometer, shutoff valve, and adjustable, temperature-control handle. Cabinet: Factory fabricated, stainless steel, for surface mounting; with controls and thermometer mounted on front. Tempered-Water Setting: . Tempered-Water Design Flow Rate: . Tempered-Water Outlet Size: end connection. Hot- and Cold-Water Inlet Size: end connections. Copy "Individual-Fixture, Water Tempering Valves" Paragraph below and re-edit for each type of water tempering valve required. If only one type is required, drawing designation may be omitted. Individual-fixture, water tempering valves in first paragraph below are unsuitable for service as primary water tempering valves. Valves below are available in NPS3/4 (DN20) and larger; however, devices in "Water-Temperature Limiting Devices" Paragraph should be used instead. Individual-Fixture, Water Tempering Valves : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Acorn Engineering Company. Apollo Flow Controls; Conbraco Industries, Inc. Cash Acme; a division of Reliance Worldwide Corporation. Honeywell. Lawler Manufacturing Company, Inc. Leonard Valve Company. POWERS; a WATTS brand. . Standard: ASSE1016, thermostatically controlled, water tempering valve. Pressure Rating: 125 psig (860 kPa) minimum unless otherwise indicated. Body: Bronze body with corrosion-resistant interior components. Temperature Control: Adjustable. Inlets and Outlet: Threaded. Finish: Rough or chrome-plated bronze. Tempered-Water Setting: . Retain "Tempered-Water Design Flow Rate" Subparagraph below only if required. Tempered-Water Design Flow Rate: . Copy "Primary Water Tempering Valves" Paragraph below and re-edit for each type of water tempering valve required. If only one type is required, drawing designation may be omitted. Primary water tempering valves in paragraph below are available in NPS1/2 to NPS4 (DN15 to DN100). Primary Water Tempering Valves : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Heat-Timer Corporation. Holby Valve Inc. . Standard: ASSE1017, thermostatically controlled, water tempering valve, listed as tempering valve. Pressure Rating: 125 psig (860 kPa) minimum unless otherwise indicated. Body: Bronze. Temperature Control: Manual. Inlets and Outlet: Threaded. Selected Primary Water Tempering Valve Size: . Tempered-Water Setting: . Tempered-Water Design Flow Rate: . Pressure Drop at Design Flow Rate: . Tempered-Water Outlet Size: end connection. Cold-Water Inlet Size: end connection. Hot-Water Inlet Size: end connection. Valve Finish: [Rough bronze] . STRAINERS FOR DOMESTIC WATER PIPING Copy "Y-Pattern Strainers" Paragraph below and re-edit for each type of Y-pattern strainer required. If only one type is required, drawing designation may be omitted. Y-Pattern Strainers : Pressure Rating: 125 psig (860 kPa) minimum unless otherwise indicated. Body: Bronze for NPS2 (DN50) and smaller; cast iron[with interior lining that complies with AWWAC550 or that is FDA approved, epoxy coated and] for NPS2-1/2 (DN65) and larger. End Connections: Threaded for NPS2 (DN50) and smaller; flanged for NPS2-1/2 (DN65) and larger. Screen: Stainless steel with round perforations unless otherwise indicated. If retaining more than one screen size, indicate screen size on Drawings. Perforation Size: Strainers NPS2 (DN50) and Smaller: [0.020 inch (0.51 mm)] [0.033 inch (0.84 mm)] [0.062 inch (1.57 mm)] . Strainers NPS2-1/2 to NPS4 (DN65 to DN100): [0.045 inch (1.14 mm)] [0.062 inch (1.57 mm)] [0.125 inch (3.18 mm)] . Strainers NPS5 (DN125) and Larger: [0.10 inch (2.54 mm)] [0.125 inch (3.18 mm)] [0.25 inch (6.35 mm)] . Drain: [Pipe plug] [Factory-installed, hose-end drain valve]. OUTLET BOXES Authorities having jurisdiction may require backflow preventers in water-supply piping or on hose-thread outlets. Copy "Clothes Washer Outlet Boxes PVC" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Clothes Washer Outlet Boxes, PVC : For product information about Oateys; "CentroII Washing Machine Outlet Boxes", see  HYPERLINK "http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/centro-wmob-ii-submittal.pdf" www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/centro-wmob-ii-submittal.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; CentroII Washing Machine Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. Guy Gray Manufacturing Co., Inc. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Combination valved fitting or separate hot- and cold-water valved fittings complying with ASMEA112.18.1. Include garden-hose thread complying with ASMEB1.20.7 on outlets. Supply Shutoff Fittings: NPS1/2 (DN15) gate, globe, or ball valves and NPS1/2 (DN15) copper, water tubing. Drain: [NPS1-1/2 (DN40)] [NPS2 (DN50)] standpipe and P-trap for direct waste connection to drainage piping. Retain "Inlet Hoses" or "Drain Hose" Subparagraph below, or both, if required. Hoses are usually included with clothes washers. Inlet Hoses: Two 60-inch- (1500-mm-) long, rubber household clothes washer inlet hoses with female, garden-hose-thread couplings. Include rubber washers. Drain Hose: One 48-inch- (1200-mm-) long, rubber household clothes washer drain hose with hooked end. Copy "Clothes Washer Outlet Boxes, Fire Rated" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Clothes Washer Outlet Boxes, Fire-Rated : For product information about Oateys "Fire-Rated Washing Machine Outlet Boxes", see  HYPERLINK "http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/FIRE%20WMOB.pdf" www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/FIRE%20WMOB.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Fire-Rated Washing Machine Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. Guy Gray Manufacturing Co., Inc. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Combination valved fitting or separate hot- and cold-water valved fittings complying with ASMEA112.18.1. Include garden-hose thread complying with ASMEB1.20.7 on outlets. Supply Shutoff Fittings: NPS1/2 (DN15) gate, globe, or ball valves and NPS1/2 (DN15) copper, water tubing. Drain: [NPS1-1/2 (DN40)] [NPS2 (DN50)] standpipe and P-trap for direct waste connection to drainage piping. Retain "Inlet Hoses" or "Drain Hose" Subparagraph below, or both, if required. Hoses are usually included with clothes washers. Inlet Hoses: Two 60-inch- (1500-mm-) long, rubber household clothes washer inlet hoses with female, garden-hose-thread couplings. Include rubber washers. Drain Hose: One 48-inch- (1200-mm-) long, rubber household clothes washer drain hose with hooked end. Copy "Clothes Washer Outlet Boxes, Metal" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Clothes Washer Outlet Boxes, Metal : For product information about Oateys "Metal Washing Machine Outlet Boxes", see  HYPERLINK "http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/Metal_WMOB_Submittal.pdf" www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/Metal_WMOB_Submittal.pdf . Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Metal Washing Machine Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. Guy Gray Manufacturing Co., Inc. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: 20-gauge, 0.0375-inch (0.95-mm) box and 18 gauge, 0.05-inch (1.27-mm) faceplate. Faucet: Combination valved fitting or separate hot- and cold-water valved fittings complying with ASMEA112.18.1. Include garden-hose thread complying with ASMEB1.20.7 on outlets. Supply Shutoff Fittings: NPS1/2 (DN15) gate, globe, or ball valves and NPS1/2 (DN15) copper, water tubing. Drain: [NPS1-1/2 (DN40)] [NPS2 (DN50)] standpipe and P-trap for direct waste connection to drainage piping. Retain "Inlet Hoses" or "Drain Hose" Subparagraph below, or both, if required. Hoses are usually included with clothes washers. Inlet Hoses: Two 60-inch- (1500-mm-) long, rubber household clothes washer inlet hoses with female, garden-hose-thread couplings. Include rubber washers. Drain Hose: One 48-inch- (1200-mm-) long, rubber household clothes washer drain hose with hooked end. Copy "Clothes Washer Outlet Boxes, Modular" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Clothes Washer Outlet Boxes, Modular : For product information about Oateys "Modular Wash Machine Outlet Boxes", see https://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/ModaSpecifications_WashingMachineOutletBox.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Moda Washing Machine Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. Guy Gray Manufacturing Co., Inc. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Combination valved fitting or separate hot- and cold-water valved fittings complying with ASMEA112.18.1. Include garden-hose thread complying with ASMEB1.20.7 on outlets. Supply Shutoff Fittings: NPS1/2 (DN15) gate, globe, or ball valves and NPS1/2 (DN15) copper, water tubing. Drain: [NPS1-1/2 (DN40)] [NPS2 (DN50)] standpipe and P-trap for direct waste connection to drainage piping. Retain "Inlet Hoses" or "Drain Hose" Subparagraph below, or both, if required. Hoses are usually included with clothes washers. Inlet Hoses: Two 60-inch- (1500-mm-) long, rubber household clothes washer inlet hoses with female, garden-hose-thread couplings. Include rubber washers. Drain Hose: One 48-inch- (1200-mm-) long, rubber household clothes washer drain hose with hooked end. Copy "Icemaker Outlet Boxes, Fire-Rated" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Icemaker Outlet Boxes, Fire-Rated : For product information about Oateys "Fire-Rated Icemaker Outlet Boxes", see  HYPERLINK "http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/fire-imob.pdf" www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/fire-imob.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Fire-Rated Icemaker Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. Copy "Icemaker Outlet Boxes, Metal" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Icemaker Outlet Boxes, Metal : For product information about Oateys "Fire-Rated Icemaker Outlet Boxes", see  HYPERLINK "http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/Metal20IMB2.pdf" www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/Metal20IMB2.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Metal Icemaker Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: Galvanized steel with powder-coated white finish box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. Copy "Icemaker Outlet Boxes, Modular" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Icemaker Outlet Boxes, Modular : For product information about Oateys "Modular Icemaker Outlet Boxes", see https://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/ModaSpecifications_IceMakerSupplyBox.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Moda Icemaker Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. Copy "Kitchen Outlet Boxes, Modular" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Kitchen Outlet Boxes, Modular : For product information about Oateys "Modular Kitchen Outlet Boxes", see https://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/ModaSpecifications_KitchenSupplyBox.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Moda Kitchen Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. Copy "Lavatory Outlet Boxes, Modular" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Lavatory Outlet Boxes, Modular : For product information about Oateys "Modular Lavatory Outlet Boxes", see https://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/ModaSpecifications_LavatorySupplyBox.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Moda Lavatory Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. Copy "Toilet/Dishwasher Outlet Boxes, Modular" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Toilet/Dishwasher Outlet Boxes, Modular : For product information about Oateys "Modular Toilet/Dishwasher Outlet Boxes", see https://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/ModaSpecifications_ToiletSupplyBox.pdf. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Moda Toilet/Dishwasher Outlet Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. Copy "Air Admittance Valve Outlet Boxes" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Air Admittance Valve Outlet Boxes, : For product information about Oateys "Modular Air Admittance Valve Outlet Boxes", see https://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; SureVent Air Admittance Valve Wall Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. Copy "Wall Outlet Boxes" Paragraph below and re-edit for each type of outlet box required. If only one type is required, drawing designation may be omitted. Wall Outlet Boxes,: For product information about Oateys "Modular SureVent WallOutlet Boxes", see https://www.oatey.com/ASSETS/DOCUMENTS/ITEMS. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; SureVent Boxes or comparable product by one of the following: Acorn Engineering Company. IPS Corporation. LSP Products Group, Inc. Plastic Oddities. . Mounting: Recessed. Material and Finish: PVC box and faceplate. Faucet: Valved fitting complying with ASMEA112.18.1. Include NPS1/2 (DN15) or smaller copper tube outlet. Supply Shutoff Fitting: NPS1/2 (DN15) gate, globe, or ball valve and NPS1/2 (DN15) copper, water tubing. HOSE STATIONS Authorities having jurisdiction may require backflow preventers in water-supply piping or on hose-thread outlets. Revise this article to suit Project. Copy "Single-Temperature-Water Hose Stations" Paragraph below and re-edit for each type of hose station required. If only one type is required, drawing designation may be omitted. Single-Temperature-Water Hose Stations : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: ARCHON Industries, Inc. Armstrong International, Inc. Cooney Brothers, Inc. DynaFluid Ltd. Leonard Valve Company. . Standard: ASMEA112.18.1. Cabinet: Stainless steel enclosure with exposed valve handle, hose connection, and hose rack. Include thermometer in front. Hose-Rack Material: Stainless steel. Body Material: Bronze[with stainless steel wetted parts]. Body Finish: Rough bronze[,chrome plated]. Mounting: [Wall, with reinforcement] [Floor, with stainless steel pedestal]. Supply Fittings: [NPS1/2 (DN15)] [NPS3/4 (DN20)] gate, globe, or ball valve and check valve and [NPS1/2 (DN15)] [NPS3/4 (DN20)] copper, water tubing. Omit check valve if check stop is included with fitting. Hose: Manufacturer's standard, for service fluid, temperature, and pressure; [25 feet (7.6m)] [50 feet (15m)] long. Nozzle: With hand-squeeze, on-off control. Vacuum Breaker: Integral or factory-installed, nonremovable, manual-drain-type, hose-connection vacuum breaker complying with ASSE1011 or backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7 on outlet. Copy "Hot- and Cold-Water Hose Stations" Paragraph below and re-edit for each type of hose station required. If only one type is required, drawing designation may be omitted. Hot- and Cold-Water Hose Stations : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: ARCHON Industries, Inc. Armstrong International, Inc. Cooney Brothers, Inc. DynaFluid Ltd. Leonard Valve Company. . Standard: ASMEA112.18.1. Faucet Type: [Blending] [Thermostatic mixing] valve. Cabinet: Stainless-steel enclosure with exposed valve handles, hose connection, and hose rack. Include thermometer in front. Hose-Rack Material: Stainless steel. Body Material: Bronze[with stainless steel wetted parts]. Body Finish: Rough bronze[or chrome plated]. Mounting: [Wall, with reinforcement] [Floor, with stainless steel pedestal]. Supply Fittings: Two [NPS1/2 (DN15)] [NPS3/4 (DN20)] gate, globe, or ball valves and check valves and [NPS1/2 (DN15)] [NPS3/4 (DN20)] copper, water tubing. Omit check valves if check stops are included with fitting. Hose: Manufacturer's standard, for service fluid, temperature, and pressure; [25 feet (7.6m)] [50 feet (15m)] long. Nozzle: With hand-squeeze, on-off control. Vacuum Breaker: Integral or factory-installed, nonremovable, manual-drain-type, hose-connection vacuum breaker complying with ASSE1011 or backflow preventer complying with ASSE1052; and garden-hose thread complying with ASMEB1.20.7 on outlet. Copy "Cold-Water and Steam Hose Stations" Paragraph below and re-edit for each type of hose station required. If only one type is required, drawing designation may be omitted. Cold-Water and Steam Hose Stations : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: ARCHON Industries, Inc. Armstrong International, Inc. Cooney Brothers, Inc. DynaFluid Ltd. Leonard Valve Company. . Standard: ASMEA112.18.1. Faucet Type: [Blending] [Thermostatic mixing] valve. Cabinet: Stainless-steel enclosure with exposed valve handles, hose connection, and hose rack. Include thermometer in front. Hose-Rack Material: Stainless steel. Body Material: Bronze[with stainless steel wetted parts]. Body Finish: Rough bronze[or chrome plated]. Mounting: [Wall, with reinforcement] [Floor, with stainless steel pedestal]. Supply Fittings: Two [NPS1/2 (DN15)] [NPS3/4 (DN20)] gate, globe, or ball valves and check valves and [NPS1/2 (DN15)] [NPS3/4 (DN20)] copper, water tubing. Omit check valves if check stops are included with fitting. Hose: Manufacturer's standard, for service fluid, temperature, and pressure; [25 feet (7.6m)] [50 feet (15m)] long. Nozzle: With hand-squeeze, on-off control. Vacuum Breaker: Integral or factory-installed, nonremovable, manual-drain-type, hose-connection vacuum breaker complying with ASSE1011 or backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7 on outlet. HOSE BIBBS Copy "Hose Bibbs" Paragraph below for each type of hose bibb required. If only one type is required, drawing designation may be omitted. Hose Bibbs : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Jay R. Smith Mfg. Co. Josam Company. MIFAB, Inc. Prier Products, Inc. . Standard: ASMEA112.18.1 for sediment faucets. Body Material: Bronze. Seat: Bronze, replaceable. Supply Connections: NPS1/2 or NPS3/4 (DN15 or DN20) threaded or solder-joint inlet. Outlet Connection: Garden-hose thread complying with ASMEB1.20.7. Pressure Rating: 125 psig (860 kPa). Vacuum Breaker: Integral[or field-installation,] nonremovable, drainable, hose-connection vacuum breaker complying with ASSE1011. Finish for Equipment Rooms: Rough bronze, or chrome or nickel plated. Finish for Service Areas: [Rough bronze] [Chrome or nickel plated]. Finish for Finished Rooms: Chrome or nickel plated. Operation for Equipment Rooms: Wheel handle or operating key. Operation for Service Areas: [Wheel handle] [Operating key]. Operation for Finished Rooms: [Wheel handle] [Operating key]. Include operating key with each operating-key hose bibb. Include[integral] wall flange with each chrome- or nickel-plated hose bibb. WALL HYDRANTS Wall hydrants without integral vacuum breakers or backflow preventers are available but not recommended. Copy "Nonfreeze Wall Hydrants" Paragraph below for each type of wall hydrant required. If only one type is required, drawing designation may be omitted. Nonfreeze Wall Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Jay R. Smith Mfg. Co. Josam Company. MIFAB, Inc. Prier Products, Inc. . Standard: ASMEA112.21.3M for [concealed] [exposed]-outlet, self-draining wall hydrants. Pressure Rating: 125 psig (860 kPa). Operation: Loose key. Casing and Operating Rod: Of length required to match wall thickness. Include wall clamp. Inlet: NPS3/4 or NPS1 (DN20 or DN25). Outlet: Concealed, with integral vacuum breaker and garden-hose thread complying with ASMEB1.20.7. Box: Deep, flush mounted with cover. Box and Cover Finish: [Polished nickel bronze] [Chrome plated] . Retain "Outlet," "Box," and "Box and Cover Finish" subparagraphs above for concealed-outlet-type wall hydrants or "Outlet" and "Nozzle and Wall-Plate Finish" subparagraphs below for exposed-outlet-type wall hydrants. Outlet: Exposed, with integral vacuum breaker and garden-hose thread complying with ASMEB1.20.7. Nozzle and Wall-Plate Finish: [Polished nickel bronze] [Rough bronze] . Operating Keys(s): [One] [Two] with each wall hydrant. Copy "Nonfreeze, Hot- and Cold-Water Wall Hydrants" Paragraph below and re-edit for each type of wall hydrant required. If only one type is required, drawing designation may be omitted. Nonfreeze, Hot- and Cold-Water Wall Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Jay R. Smith Mfg. Co. Josam Company. Prier Products, Inc. . Standard: ASMEA112.21.3M for [concealed] [exposed]-outlet, self-draining wall hydrants. Pressure Rating: 125 psig (860 kPa). Operation: Loose key. Casing and Operating Rods: Of length required to match wall thickness. Include wall clamps. Inlet: NPS3/4 or NPS1 (DN20 or DN25). Outlet: Concealed. Box: Deep, flush mounted with cover. Box and Cover Finish: [Polished nickel bronze] [Chrome plated] . Vacuum Breaker: Nonremovable, manual-drain-type, hose-connection vacuum breaker complying with ASSE1011 or backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7 on outlet. Operating Key(s): [One] [Two] with each wall hydrant. Copy "Moderate-Climate Wall Hydrants" Paragraph below and re-edit for each type of wall hydrant required. If only one type is required, drawing designation may be omitted. Moderate-Climate Wall Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Jay R. Smith Mfg. Co. Josam Company. MIFAB, Inc. Prier Products, Inc. . Standard: ASMEA112.21.3M for [concealed] [exposed]-outlet, self-draining wall hydrants. Pressure Rating: 125 psig (860 kPa). Operation: Loose key. Inlet: NPS3/4 or NPS1 (DN20 or DN25). Outlet: Concealed, with integral vacuum breaker or nonremovable hose-connection vacuum breaker complying with ASSE1011 or backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7. Box: Deep, flush mounted with cover. Box and Cover Finish: [Polished nickel bronze] [Chrome plated] . Retain "Outlet," "Box," and "Box and Cover Finish" subparagraphs above for concealed-outlet-type wall hydrants or "Outlet" and "Nozzle and Wall-Plate Finish" subparagraphs below for exposed-outlet-type wall hydrants. Outlet: Concealed, with integral vacuum breaker or nonremovable hose-connection vacuum breaker complying with ASSE1011 or backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7. Nozzle and Wall-Plate Finish: [Polished nickel bronze] [Rough bronze] . Operating Key(s): [One] [Two] with each wall hydrant. Copy "Vacuum Breaker Wall Hydrants" Paragraph below and re-edit for each type of wall hydrant required. If only one type is required, drawing designation may be omitted. Vacuum Breaker Wall Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: A.Y. McDonald Mfg. Co. Arrowhead Brass Products. Jay R. Smith Mfg. Co. Mansfield Plumbing Products LLC. Prier Products, Inc. . Standard: ASSE1019, TypeA or TypeB. Type: Freeze-resistant, automatic draining with integral air-inlet valve. Retain only TypeB in "Classification" Subparagraph below if hose remains attached. Classification: [TypeA, for automatic draining with hose removed or]TypeB, for automatic draining with hose removed or with hose attached and nozzle closed. Pressure Rating: 125 psig (860 kPa). Operation: [Loose key] [or] [wheel handle]. Casing and Operating Rod: Of length required to match wall thickness. Include wall clamp. Inlet: NPS1/2 or NPS3/4 (DN15 or DN20). Outlet: Exposed with garden-hose thread complying with ASMEB1.20.7. GROUND HYDRANTS Retain this article only if ground hydrants are required and are not specified in Section221113 "Facility Water Distribution Piping." Vacuum breakers are ineffective on this type of hydrant. If using ground hydrants, a backflow preventer in supply piping is recommended. Copy "Nonfreeze Ground Hydrants" Paragraph below and re-edit for each type of ground hydrant required. If only one type is required, drawing designation may be omitted. Nonfreeze Ground Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Jay R. Smith Mfg. Co. Josam Company. MIFAB, Inc. Murdock-Super Secur; a member of Morris Group International. Prier Products, Inc. . Standard: ASMEA112.21.3M. Type: Nonfreeze, concealed-outlet ground hydrant with box. Operation: Loose key. Casing and Operating Rod: Of at least length required for burial of valve below frost line. Inlet: NPS3/4 (DN20). Outlet: Garden-hose thread complying with ASMEB1.20.7. Drain: Designed with hole to drain into ground when shut off. Box: [Standard] [Deep] pattern with cover. Box and Cover Finish: [Rough] [Polished nickel] bronze. Operating Key(s): [One] [Two] with each ground hydrant. Vacuum breaker in "Vacuum Breaker" Subparagraph below is ineffectual because of ground-level location. If required, include a deep box. Vacuum Breaker: ASSE1011. POST HYDRANTS Retain this article only if post hydrants are required and are not specified in Section221113 "Facility Water Distribution Piping." Copy "Nonfreeze, Draining-Type Post Hydrants" Paragraph below and re-edit for each type of post hydrant required. If only one type is required, drawing designation may be omitted. Hydrants in first paragraph below are not recommended. Nonfreeze, nondraining-type post hydrants or freeze-resistant sanitary yard hydrants are preferred. Nonfreeze, Draining-Type Post Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Jay R. Smith Mfg. Co. MIFAB, Inc. Prier Products, Inc. . Standard: ASMEA112.21.3M. Type: Nonfreeze, exposed-outlet post hydrant. Operation: Loose key. Casing and Operating Rod: Of at least length required for burial of valve below frost line. Casing: Bronze with casing guard. Inlet: NPS3/4 (DN20). Outlet: Garden-hose thread complying with ASMEB1.20.7. Drain: Designed with hole to drain into ground when shut off. Vacuum Breaker: Nonremovable, drainable, hose-connection vacuum breaker complying with ASSE1011 or backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7 on outlet. Operating Key(s): [One] [Two] with each loose-key-operation wall hydrant. Copy "Nonfreeze, Nondraining-Type Post Hydrants" Paragraph below and re-edit for each type of post hydrant required. If only one type is required, drawing designation may be omitted. Nonfreeze, Nondraining-Type Post Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Murdock-Super Secur; a member of Morris Group International. Operation: Lever-piston operating mechanism and nondraining water-storage reservoir, designed without drain. Length: As required for burial of valve below frost line. Inlet: NPS1 (DN25) threaded. Outlet: Retain one of first four subparagraphs below. NPS1 (DN25) outlet and coupling plug for 1-inch (25-mm) hose. NPS1 by NPS3/4 (DN25 by DN20) adapter with nonremovable, drainable, hose-connection vacuum breaker complying with ASSE1011. Garden-hose thread complying with ASMEB1.20.7 on outlet. NPS1 by NPS3/4 (DN25 by DN20) adapter with nonremovable, drainable, hose-connection backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7 on outlet. Copy "Freeze-Resistant Sanitary Yard Hydrants" Paragraph below and re-edit for each type of sanitary yard hydrant required. If only one type is required, drawing designation may be omitted. Freeze-Resistant Sanitary Yard Hydrants : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Hoeptner Products. . Standard: ASSE1057, Type5 for nondraining hydrants. Operation: Wheel handle. Head: Copper alloy, with pail hook. Inlet: NPS3/4-inch (DN20) threaded inlet and inlet nozzle, galvanized-steel riser, and venturi. Canister: [Plastic] [Zinc-plated steel] with atmospheric-vent device. Vacuum Breaker: Removable hose-connection backflow preventer complying with ASSE1052. Garden-hose thread complying with ASMEB1.20.7 on outlet for field installation. DRAIN VALVES Copy "Ball-Valve-Type, Hose-End Drain Valves" Paragraph below and re-edit for each type of drain valve required. If only one type is required, drawing designation may be omitted. Ball-Valve-Type, Hose-End Drain Valves : Standard: MSSSP-110 for standard-port, two-piece ball valves. Pressure Rating: 400-psig (2760-kPa) minimum CWP. Size: NPS3/4 (DN20). Body: Copper alloy. Ball: Chrome-plated brass. Seats and Seals: Replaceable. Handle: Vinyl-covered steel. Inlet: Threaded or solder joint. Outlet: Threaded, short nipple with garden-hose thread complying with ASMEB1.20.7 and cap with brass chain. Copy "Gate-Valve-Type, Hose-End Drain Valves" Paragraph below and re-edit for each type of drain valve required. If only one type is required, drawing designation may be omitted. Gate-Valve-Type, Hose-End Drain Valves : Standard: MSSSP-80 for gate valves. Pressure Rating: Class125. Size: NPS3/4 (DN20). Body: ASTMB62 bronze. Inlet: NPS3/4 (DN20) threaded or solder joint. Outlet: Garden-hose thread complying with ASMEB1.20.7 and cap with brass chain. Copy "Stop-and-Waste Drain Valves" Paragraph below and re-edit for each type of drain valve required. If only one type is required, drawing designation may be omitted. Stop-and-Waste Drain Valves : Standard: MSSSP-110 for ball valves or MSSSP-80 for gate valves. Pressure Rating: 200-psig (1380-kPa) minimum CWP or Class125. Size: NPS3/4 (DN20). Body: Copper alloy or ASTMB62 bronze. Drain: NPS1/8 (DN6) side outlet with cap. WATER-HAMMER ARRESTERS Copy "Water-Hammer Arresters" Paragraph below and re-edit for each type of water-hammer arrester required. If only one type is required, drawing designation may be omitted. Water-Hammer Arresters, : For product information on Oateys "Quiet Pipes Hammer Arrestors" see https://www.oatey.com/ASSETS/DOCUMENTS. Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed. Basis-of-Design Product: Subject to compliance with requirements, provide Oatey; Quiet Pipes Hammer Arrestors, or comparable product by one of the following: AMTROL, Inc. Jay R. Smith Mfg. Co. Josam Company. MIFAB, Inc. Precision Plumbing Products. . Standard: ASSE1010 or PDI-WH201. Type: Copper tube with piston. Size: ASSE1010, SizesAA and A through F, or PDI-WH201, SizesA through F. Fitting Size: [1/2 inch (13 mm)] [3/4 inch (19 mm)] [and] [1 inch (25.4 mm)]. Fitting Type: [F1960PEX] [F1807PEX] [MIP Thread] [Male Sweat] [Female Sweat] Temperature Range: 33 to 180 deg F (0.6 to 82 deg C). AIR VENTS Copy "Bolted-Construction Automatic Air Vents" Paragraph below and re-edit for each type of air vent required. If only one type is required, drawing designation may be omitted. Bolted-Construction Automatic Air Vents : Body: Bronze. Pressure Rating and Temperature: 125-psig (860-kPa) minimum pressure rating at 140 degF (60 degC). Float: Replaceable, corrosion-resistant metal. Mechanism and Seat: Stainless steel. Size: [NPS3/8 (DN10)] [NPS1/2 (DN15)] minimum inlet. Inlet and Vent Outlet End Connections: Threaded. Copy "Welded-Construction Automatic Air Vents" Paragraph below and re-edit for each type of air vent required. If only one type is required, drawing designation may be omitted. Welded-Construction Automatic Air Vents : Body: Stainless steel. Pressure Rating: 150-psig (1035-kPa) minimum pressure rating. Float: Replaceable, corrosion-resistant metal. Mechanism and Seat: Stainless steel. Size: NPS3/8 (DN10) minimum inlet. Inlet and Vent Outlet End Connections: Threaded. TRAP-SEAL PRIMER DEVICE Copy "Supply-Type, Trap-Seal Primer Device" Paragraph below and re-edit for each type of primer valve required. If only one type is required, drawing designation may be omitted. Supply-Type, Trap-Seal Primer Device : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Jay R. Smith Mfg. Co. MIFAB, Inc. Precision Plumbing Products. . Standard: ASSE1018. Pressure Rating: 125 psig (860 kPa) minimum. Body: Bronze. Inlet and Outlet Connections: NPS1/2 (DN15) threaded, union, or solder joint. Gravity Drain Outlet Connection: NPS1/2 (DN15) threaded or solder joint. Finish: Chrome plated, or rough bronze for units used with pipe or tube that is not chrome finished. Copy "Drainage-Type, Trap-Seal Primer Device" Paragraph below and re-edit for each type of primer valve required. If only one type is required, drawing designation may be omitted. Drainage-Type, Trap-Seal Primer Device : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Jay R. Smith Mfg. Co. . Standard: ASSE1044, lavatory P-trap with NPS3/8 (DN10) minimum, trap makeup connection. Size: NPS1-1/4 (DN32) minimum. Material: Chrome-plated, cast brass. TRAP-SEAL PRIMER SYSTEMS Copy "Trap-Seal Primer Systems" Paragraph below and re-edit for each type of primer system required. If only one type is required, drawing designation may be omitted. Trap-Seal Primer Systems : Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by the following: Precision Plumbing Products. . Standard: ASSE1044. Piping: NPS3/4, ASTMB88, TypeL (DN20, ASTMB88M, TypeB); copper, water tubing. Cabinet: [Recessed] [Surface]-mounted steel box with stainless-steel cover. Electric Controls: 24-hour timer, solenoid valve, and manual switch for 120-Vac power. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA70, by a qualified testing agency, and marked for intended location and application. Vacuum Breaker: ASSE1001. Number Outlets: [Four] [Six] [Eight] . Size Outlets: [NPS1/2 (DN15)] [NPS5/8 (DN18)]. FLEXIBLE CONNECTORS Retain "Manufacturers" Paragraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: Flex Pression Ltd. Flex-Hose Co., Inc. Flexicraft Industries. Flex-Weld, Inc. Hyspan Precision Products, Inc. Mercer Gasket & Shim, Inc. Metraflex Company (The). . Bronze-Hose Flexible Connectors: Corrugated-bronze tubing with bronze wire-braid covering and ends brazed to inner tubing. Working-Pressure Rating: Minimum [200 psig (1380 kPa)] [250 psig (1725 kPa)]. End Connections NPS2 (DN50) and Smaller: Threaded copper pipe or plain-end copper tube. End Connections NPS2-1/2 (DN65) and Larger: Flanged copper alloy. Stainless-Steel-Hose Flexible Connectors: Corrugated-stainless-steel tubing with stainless-steel wire-braid covering and ends welded to inner tubing. Working-Pressure Rating: Minimum [200 psig (1380 kPa)] [250 psig (1725 kPa)]. End Connections NPS2 (DN50) and Smaller: Threaded steel-pipe nipple. End Connections NPS2-1/2 (DN65) and Larger: Flanged steel nipple. WATER METERS Sustainable design systems have provisions for water meters to measure fixture use separate from irrigation. Retain this article if Contractor is to furnish water meters, and water meters are to be installed inside the building. Verify type of water meter required by the utility company and authorities having jurisdiction. Retain "Displacement-Type Water Meters" Paragraph below for water meters NPS2 (DN50) and smaller. Displacement-type meters with plastic cases that comply with AWWAC710 are also available. Displacement-Type Water Meters: Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers.  HYPERLINK "http://www.specagent.com/Lookup?ulid=2066" Manufacturers: Subject to compliance with requirements, provide products by one of the following:  HYPERLINK "http://www.specagent.com/Lookup?uid=123457113832" AALIANT.  HYPERLINK "http://www.specagent.com/Lookup?uid=123457113828" ABB.  HYPERLINK "http://www.specagent.com/Lookup?uid=123457113831" Carlon Meter.  HYPERLINK "http://www.specagent.com/Lookup?uid=123457113827" Mueller Co. . Standard: AWWAC700. Pressure Rating: 150-psig (1035-kPa) working pressure. Body Design: Nutating disc; totalization meter. Registration: In gallons (liters) or cubic feet (cubic meters) as required by utility company. Case: Bronze. End Connections: Threaded. Retain "Turbine-Type Water Meters" Paragraph below for water meters NPS1-1/2 to NPS10 (DN40 to DN250). Turbine-Type Water Meters: Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: AALIANT. ABB. Badger Industries, Inc. Hays Fluid Controls. Master Meter, Inc. McCrometer, Inc. Mueller Co. . Standard: AWWAC701. Pressure Rating: [150 psig (1035 kPa)] working pressure. Body Design: Turbine; totalization meter. Registration: In gallons (liters) or cubic feet (cubic meters) as required by utility company. Case: Bronze. End Connections for Meters NPS2 (DN50) and Smaller: Threaded. End Connections for Meters NPS2-1/2 (DN65) and Larger: Flanged. Retain "Compound-Type Water Meters" Paragraph below for water meters NPS3 (DN80) and larger. NPS2 (DN50) meters are also available. Compound-Type Water Meters: Retain "Manufacturers" Subparagraph and list of manufacturers below to require products from manufacturers listed or a comparable product from other manufacturers. Manufacturers: Subject to compliance with requirements, provide products by one of the following: ABB. Badger Industries, Inc. Master Meter, Inc. Mueller Co. . Standard: AWWAC702. Pressure Rating: 150-psig (1035-kPa) working pressure. Body Design: With integral mainline and bypass meters; totalization meter. Registration: In gallons (liters) or cubic feet (cubic meters) as required by utility company. Case: Bronze. Pipe Connections: Flanged. Remote Registration System: Encoder type complying with AWWAC707; modified with signal-transmitting assembly, low-voltage connecting wiring, and remote register assembly as required by utility company. EXECUTION INSTALLATION Backflow Preventers: Install backflow preventers in each water supply to mechanical equipment and systems and to other equipment and water systems that may be sources of contamination. Comply with authorities having jurisdiction. Locate backflow preventers in same room as connected equipment or system. Install drain for backflow preventers with atmospheric-vent drain connection with air-gap fitting, fixed air-gap fitting, or equivalent positive pipe separation of at least two pipe diameters in drain piping and pipe-to-floor drain. Locate air-gap device attached to or under backflow preventer. Simple air breaks are unacceptable for this application. Do not install bypass piping around backflow preventers. Water Regulators: Install with inlet and outlet shutoff valves[and bypass with memory-stop balancing valve]. Install pressure gages on inlet and outlet. Water Control Valves: Install with inlet and outlet shutoff valves[and bypass with globe valve]. Install pressure gages on inlet and outlet. Automatic Water Shutoff Valves: Test for signal strength before valve installation. Install automatic shutoff valve downstream from main domestic water shutoff valve and downstream from fire sprinkler system supply. Install valve controller is an accessible location with sensors in areas where water is likely to accumulate. Balancing Valves: Install in locations where they can easily be adjusted. Temperature-Actuated, Water Mixing Valves: Install with check stops or shutoff valves on inlets and with shutoff valve on outlet. Install cabinet-type units recessed in or surface mounted on wall as specified. Y-Pattern Strainers: For water, install on supply side of each [control valve] [water pressure-reducing valve] [solenoid valve] [and] [pump]. Outlet Boxes: Install boxes recessed in wall or surface mounted on wall. Install 2-by-4-inch (38-by-89-mm) fire-retardant-treated-wood blocking, wall reinforcement between studs. Comply with requirements for fire-retardant-treated-wood blocking in Section061000 "Rough Carpentry." Hose Stations: Install with check stops or shutoff valves on inlets and with thermometer on outlet. Install cabinet-type units recessed in or surface mounted on wall as specified. Install 2-by-4-inch (38-by-89-mm) fire-retardant-treated-wood blocking, wall reinforcement between studs. Comply with requirements for fire-retardant-treated-wood blocking in Section061000 "Rough Carpentry." Ground Hydrants: Install with [1 cu. yd. (0.75 cu.m)] of crushed gravel around drain hole. Set ground hydrants with box flush with grade. Nonfreeze, Draining-Type Post Hydrants: Install with [1 cu. yd. (0.75 cu.m)] of crushed gravel around drain hole. Set post hydrants in concrete paving or in [1 cu. yd. (0.03 cu.m)] of concrete block at grade. Nonfreeze, Nondraining-Type Post Hydrants: Set in concrete or pavement. Freeze-Resistant Sanitary Yard Hydrants: Set with riser pipe in concrete or pavement. Do not encase canister in concrete. Water-hammer arresters in first paragraph below are best shown on water risers and details. Specifying number, size, and location here is difficult. Water-Hammer Arresters: Install in water piping in accordance with PDI-WH201. Air Vents: Install vents at high points of water piping.[Install drain piping and discharge onto floor drain.] Supply-Type, Trap-Seal Primer Device: Install with outlet piping pitched down toward drain trap a minimum of 1percent, and connect to floor-drain body, trap, or inlet fitting. Adjust valve for proper flow. Drainage-Type, Trap-Seal Primer Device: Install as lavatory trap with outlet piping pitched down toward drain trap a minimum of 1percent, and connect to floor-drain body, trap, or inlet fitting. Trap-Seal Primer Systems: Install with outlet piping pitched down toward drain trap a minimum of 1percent, and connect to floor-drain body, trap, or inlet fitting. Adjust system for proper flow. CONNECTIONS Coordinate piping installations and specialty arrangements with Drawings and with requirements specified in piping systems. If Drawings are explicit enough, these requirements may be reduced or omitted. Drawings indicate general arrangement of piping, fittings, and specialties. When installing piping specialties adjacent to equipment and machines, allow space for service and maintenance. Retain paragraph below if retaining "Trap-Seal Primer Systems" Article. Comply with requirements for grounding equipment in Section260526 "Grounding and Bonding for Electrical Systems." IDENTIFICATION Plastic Labels for Equipment: Install engraved plastic-laminate equipment nameplate or sign on or near each of the following: Coordinate list below with products retained in Part2. Pressure vacuum breakers. Intermediate atmospheric-vent backflow preventers. Reduced-pressure-principle backflow preventers. Double-check, backflow-prevention assemblies. Carbonated-beverage-machine backflow preventers. Dual-check-valve backflow preventers. Reduced-pressure-detector, fire-protection, backflow-preventer assemblies. Double-check, detector-assembly backflow preventers. Water pressure-reducing valves. Automatic water shutoff valves. Calibrated balancing valves. Primary, thermostatic, water mixing valves. Manifold, thermostatic, water mixing-valve assemblies. Photographic-process, thermostatic, water mixing-valve assemblies. Primary water tempering valves. Outlet boxes. Hose stations. Supply-type, trap-seal primer valves. Trap-seal primer systems. Distinguish among multiple units, inform operator of operational requirements, indicate safety and emergency precautions, and warn of hazards and improper operations, in addition to identifying unit. Nameplates and signs are specified in Section220553 "Identification for Plumbing Piping and Equipment." FIELD QUALITY CONTROL Retain "Perform the following tests and inspections" Paragraph below to require Contractor to perform tests and inspections. Perform the following tests and inspections: Test each [pressure vacuum breaker] [reduced-pressure-principle backflow preventer] [double-check, backflow-prevention assembly] [and] [double-check, detector-assembly backflow preventer] according to authorities having jurisdiction and the device's reference standard. See Section014000 "Quality Requirements" for retesting and reinspecting requirements and Section017300 "Execution" for requirements for correcting the Work. Domestic water piping specialties will be considered defective if they do not pass tests and inspections. Prepare test and inspection reports. ADJUSTING Set field-adjustable pressure set points of water pressure-reducing valves. Set field-adjustable flow set points of balancing valves. Set field-adjustable temperature set points of temperature-actuated, water mixing valves. END OF SECTION 221119     Copyright 2017 AIA MasterSpec Full Length 09/17 PRODUCT MASTERSPEC LICENSED BY AVITRU, LLC TO OATEY. DOMESTIC WATER PIPING SPECIALTIES221119 -  PAGE 35 =}~   ^ ` 5 :  ' , . @ K L M O P U _ a b d l n w x y ĹĹĹĹh&+h&+0J:jh&+h&+U h&+h&+hwphD75\ hD75\hmWhD75\ hFbZhD7hD7 hmWhD7hhhoE=~` j -  2]h6gd=gd&+=gdD7)     4 5 H V X Y g h j r x {  , - 5   2]hvѻho% hhhh5hhh5>* ho0J. ho0J-hohf\hD70J:h= hD7>* hD7>*jhD7>*UhD7 hmWhD7@hv $9G]q dr)gdD) $9G]ABq d*8=>?@JKR_`abopqr(>?`+01Dcw01hf/hwphe0J:5hwphe5 he5jhe5U hwphDhDhFbZhoO(`+DcwY R gdr] gdr] )gdr] )0101Y 01R./././ žŲŲhFbZ0J9>*B*ph hr] hr] h?rhr] 0J9>*B*ph hQ'Uho h_0J/5 ho0J/5 hFbZ0J05 ho0J05 ho5hoE  ./;=HItv}~   . / D M Y \ i l !.!/!!!!!!!!."/"""žhhr] 0J9>*B*ph hmSho ho5 ho0J/ ho0J0ho h?rhim3hBY him35him3him35him3hr] hFbZ0J9>*B*phh?rhr] 0J9>*B*ph h?rhr] 8 =v  D l !!!"#1#K#######$$i$$gdr] gdr] )gdr] )@& gdwpgdr] """"#.#/#1#I#K#V#W##################$$$.$/$i$r$$$$$$$$.%/%C%%%%%%& &.&/&&&&&&')'*'.'/'1'סh@Lhr] 0J9>*B*ph hOho ho5ho hh~ h~ h~ 5h~ hr] hFbZ0J9>*B*ph hhr] hhr] 0J9>*B*ph hr] hr] ?$C%% &&'8'h'~'''''S(l(((( )4))z**e++@& gd Tgdr] gdr] gdr] )gdr] )1'2'6'8'f'h'o'p'w'x'|'~''''''''''''''(( ( ((((%(.(/(S(Z(`(a(d(i(j(l(((((((((üðêÜÜh ThFbZ0J/5h ThFbZ0J05h ThFbZ5h Tho5 ho0J/ ho0J0 ho5 ho0J/5 ho0J05ho h@Lh~ h~ h~ 5h~ hr] h@Lhr] h@Lhr] 0J9>*B*phhFbZ0J9>*B*ph2((((((((((((((((( )))4))))**z*******++e+s+++++++++ , ,,,,#,),;,K,a,b,̽ ho0J/ ho0J0 hIwh~ h~ h~ 5h~ hr] hIwhr] hr] hr] hIwhr] 0J9>*B*ph h@Lho ho5h ThFbZ0J/5h ThFbZ0J05h ThFbZ5h Tho5ho7++,#,b,p,,,Q--../C/a/v//0060J0112@& gdvBgd{ogdr] )gdr] )@& gd Tgd~ gdr] b,p,,,,,,--Q-t------........///A/B/C/D/^/`/a/v////////////////////000060J0000111111˼ ho0J/5 ho0J05 hh{oh{oh{o5h{ohr] hhr] hr] hr] hhr] 0J9>*B*ph hIwho ho5hoD111222222222 33393;3F3G3H3I3r3t3{3|333333333333333334444 4(4+424:4=4K4]4j4m4s4|444444445ÿ ho0J/5 ho0J05 hBhEhEhE5hEhr] hR0J9>*B*ph hBhr] hr] hr] hBhr] 0J9>*B*ph hho ho5ho@22 3;3t3333334=4K4|44f55P66V7}77777 8)@& gd Tgdr] gdr] gdr] )gdr] 55f5555566,6M6P66666777V7n7o7v7w7{7}7777777777777777777 8888898I8K8P8T8X8Y8\8h8i8v8ÿ h_0J/5 ho0J/5 hR0J05 ho0J05 hBhEhEhE5hEhr] hBhr] hR0J9>*B*ph hr] hr] hBhr] 0J9>*B*ph hBho ho5ho: 898888 99:;;;#<<<=5>>+?????@.@C@gdr] gdr] gdr] )gdr] )@& gd Tv88888888888888888888899 9 9/95969:9@9A9L9Q9Y9h9n9o9s9y999999999999999#:&:+:u:x::::::::::::::::; ;;;+;;; ho5 ho0J/ ho0J0h ThR5h ThR0J/5h ThR0J05h Tho5hoN;;W;Z;;;;;;;;;;;;;;;#<*<+<3<;<<<<<<<+======+>5>c>>>>>>>+?9????????????????????@@@@ԺԺԺԺhEhr] h%&hr] hR0J9>*B*ph hr] hr] h%&hr] 0J9>*B*ph h$@4ho ho0J/ ho0J0ho ho5C@'@+@-@.@C@@@@@@@@@@@@@@@@@@@@@@@A AAAAA$A%A'AIAOAPASAYAZA\AAAAAAAAAAAAAA踸踰踰踰薐踰 ho0J/ ho0J0h Th_0J/5h Th_0J05h Th_5h Tho5 ho5 h_0J/5 ho0J/5 h_0J05 ho0J05 h Thoho h%&hEhEhEhE58C@@@A'A\AABiCCC"DDTEEIFFHGxGGGGHH4HgdEgdr] gdr] )gdr] )@& gd TAAAAAAAAAAAAAB BBnBqBBBBBBBBBBBBBCC!C0C7C:CECKCTC\CiCCCCCCCCCCCCCCC"D)D2D:DDDDDDDTEEEEEEE%FFFIFFFFFFF hSn0ho ho5 ho0J/ ho0J0hoh Th_0J/5h Th_0J05PFFHGvGwGxGyGGGGGGGGGGGGGHHH4HHHHHHHyIIIIIIIIIgJuJvJJJJJJJJJKKKKKKGKIK¼ȷȰꡡh_0J9>*B*ph h#hr] h#hr] 0J9>*B*ph hxho ho5 ho0J/ ho0J0ho hxhEhEhE5hEhr] hxhr] hr] hr] hxhr] 0J9>*B*ph84HHyIIgJJJKIK_KuKKKKKKL-L|LLrM"NN/OOO@& gd Tgdr] gdr] gdr] )gdr] )IKPKQKXKYK]K_KsKuKKKKKKKKKKKKKKKKKKKL,L-L4L;LCLFLMLULXL]LeLhLqLyL|LLLLLLLrMMMMMM"NgNNNNNNN/Oüüüüðé h.&sho ho5 ho0J/5 ho0J05ho h#hEhEhE5hEhr] h#hr] h_0J9>*B*phh#hr] 0J9>*B*ph?/O=OOOOOOOOOOOOOOOOOOOOP=P>PDPVPfPhPPPPPPPPQQQQQQ/RzRRRRRRRRBSPSSh &hr] 0J9>*B*ph hV%2ho ho5 ho0J/ ho0J0ho hh<8h<8h<85h<8hr] hhr] h_0J9>*B*phhhr] 0J9>*B*ph hr] hr] h=phr] 0J9>*B*ph4OOOP>PhPPPQ/RRBSSSST/TkTTTU5UjUUcV}Vgdr] gdr] )gdr] )@& gd Tgdr] SSSSSSSSSSSSSTT T TTTTT,T.T/TkTTTTTTTTTTTTTTTTTTTUUU Uwh Th_0J/5h Th_0J05h Th_5h Tho5 ho5 h_0J/5 ho0J/5 h_0J05 ho0J05ho h &h<8h<8h<85h<8hr] h &hr] h_0J9>*B*phh &hr] 0J9>*B*ph hr] hr] . U UU"U(U)U,U2U3U5UWU]U^UaUgUhUjUtUUUUUUUUUUUUUUUNVQV`VcVnVvV}VVVVVVVVVWWW!W.WnWvW~WWWWW+XnXvXXXXXnYvYYYYYYYYnZvZZ h &ho ho5h Th_0J/5h Th_0J05h Th_5h Tho5hoM}V!W.W~WW+XXYYZZ[@[V[t[[[:\S\y\\\]]e^@& gd Tgdr] gdr] gdr] )gdr] )ZZZZZZ[[ [ [[[>[@[G[H[O[P[T[U[V[W[n[q[r[s[t[[[[[[[[[[[[[[ \ \:\A\G\H\K\h ThVle0J05h ThVle5h Tho5 ho5 hVle0J/5 ho0J/5 hVle0J05 ho0J05ho h2hS2mhS2mhS2m5hS2mhr] h2hr] hVle0J9>*B*ph hr] hr] h2hr] 0J9>*B*ph.K\P\Q\S\X\f\l\m\p\v\w\y\\\\\\\\\\\\\\\\\']@]C]T]]]]]]]]]]]]'^;^>^F^I^T^]^e^r^^^^^'_T_____'`T`u```````'aTabapa˼hvnhr] 0J9>*B*ph h8U~ho ho5h ThVle0J05h ThVle5h Tho5hoh ThVle0J/5Je^r^^'__u``baaa b b_bbbbcddueeff3fgdr] @& gd TgdS2mgdr] gdr] )gdr] )paaaaaaaaab b b b'b1bFbObTb^b_bkb}bbbbbbbbbb'cTccccc'dTdddddddd'eTeueeeeeefff¼¼¼ȷȰ h`Uhr] h`Uhr] 0J9>*B*ph h?)ho ho5 ho0J/ ho0J0ho hvnhS2mhS2mhS2m5hS2mhr] hvnhr] hvnhr] 0J9>*B*ph hr] hr] 8ffffff%f1f2f3f4fNfPfQfTffffff%gTggggggghh%hThhhhhhi%iKiMiTiXiYiZi[iiiiiiiiiiiiiiþ÷֓ hy0hS2m hy0hr] hr] hr] hy0hr] 0J9>*B*ph h`Uho ho5ho h`UhS2mhS2mhS2m5hS2mhr] h`Uhr] h`Uhr] 0J9>*B*phhVle0J9>*B*ph:3fQfffgghhiMiiiiijjEjqjjokkllmVm@& gd Tgdr] gdr] )gdr] )gdr] iiijjj jjjjjjj2j8j9j*B*ph hy0ho7Vmm\nonnnnn o_o=ppppq2q^qqr%ruuvvvgdr] )@& gd Tgdr] @& gd Tgdr] gdr] )gdr] &q)q/q0q2qJqPqQqUq[q\q^qxqyqqqqqqqqqqqqqqqqqqqqr$r%rrrsrrr$srsssss$trtsttt$urusuuuu$vrvsvuvvvvvv翿 hr] hr] h|rQhr] h|rQhr] 0J9>*B*ph hHho ho5 ho0J/ ho0J0h ThVle5h Tho5hoh ThVle0J/5h ThVle0J05@vvvvvww w w$w&w'wFwrwswwwwwxlxmxxxxxxxxxxxxxxxxxxxy yyyyyy/y2yEyKyLyOyUyVyXyfygypyvywyüüüüüüϴϴh Th0J/5h Th0J05h Th5h Tho5 ho0J/5 ho0J05 ho5ho h|rQhS2mhS2mhS2m5hS2mhr] h|rQhr] h|rQhr] 0J9>*B*phzDzHzIzLz[z\z^z_zozzz{){Z{i{{{| |%|(|/|8|@|C|H|P|S|X|Y|a|d|i|t|w|||||| } }}8}W}X}Y}h}j}z}}}}}}}}}h ho0J/ ho0J0 ho5 h0J/5 ho0J/5 h0J05 ho0J05hoh Th0J/5h Th0J05Hj}}}}}}2~~}1{ɀ%FcˁƂVt)}}}} ~2~X~Y~g~~~ XYg} '/1BITXYgy{ǀɀހ %FXYcgˁ XYgƂ VXYg XYgtDŽӄՄ؄ڄ ho0J/ ho0J0 ho5hoh[DŽ#bąApLJۇ3Xӈ#A_}) #5LST_bqsv…ąASTbSTbpćŇLJۇ !.3; h0J/5 ho0J/5 h0J05 ho0J05 ho0J/ ho0J0 ho5hoR;=@BERUXfgsuxzȈӈ #.036AU_fg}ӉՉNUfg$8PU\^acfgisvyً1OU ho0J/ ho0J0ho ho5\}ՉN$8Pi1O|.~ukː)Ufg|ЌьӌԌ֌.Uhi~Uhi؎Uhiu ThiknoɐʐːRhiʑϑJRYadmnru̒*2 ho0J05 ho5hj.ho5h ho0J/ ho0J0hoUːJu̒A}ēOz-`ޖL+b[ S@& gdj.)2>ARmn}ēORmnRmnz &*+-I`klv–Öǖʖ˖ΖіҖՖٖؖۖޖhj.h5 h5 ho5 h0J/5 h0J05 ho0J05 ho0J/ ho0J0ho ho0J/5L !"%(-3569?CIJLݗ"+Db"'D[ "DRSmnh]U ho0J/ ho0J0 h]U0J/5 h]U0J05 h]U5 ho5 h0J05 ho0J05ho h0J/5 ho0J/5HSE *Bb G]|E)!"%DLS\w}!DE !*BDb!D DG]^!"%',2458:?EGH h]U0J/5 ho0J/5 h]U0J05 ho0J05h]U ho0J/ ho0J0 ho5hoPHKNSY[\_`eop|E[ȡɡH$Hݣ(+HϤݤ1HMOZ\kmvwxy˼hKhr] h)hr] hr] hr] h)hr] 0J9>*B*ph hVhoh]U h]U5 ho5 h]U0J/5 ho0J/5 h]U0J05 ho0J05ho@$ݣ+Ϥ1O\mxUgV֨@& gdj.gdr] gdr] gdr] )gdr] )y FHKSUHgHVdeԨ֨H{ hhhKhr] hr] hr] hhhr] hhhr] 0J9>*B*ph h]ho ho0J/ ho0J0 ho5ho h)hKhKhKhK5B{é̪DhwȬ$Vv­ Cmgdr] gdr] gdr] )gdr] )@& gdj.©éH̪ HBDHfhuwƬǬȬɬ$5=HUV\aiv­ CHmÿ haLhKhKhK5hKhr] hr] hr] haLhr] haLhr] 0J9>*B*ph hhho ho5 ho0J/ ho0J0hoEm HHŰH;=FGHIJKtvŲƲʲ˲̲Ͳ"ÿ ho0J/ ho0J0 hhKhKhK5hKhr] h]U0J9>*B*ph hhr] hr] hr] hhr] 0J9>*B*ph haLho ho5ho@m =v̲$[г6fҴ5@& gdj.gdr] gdr] gdr] )gdr] )"#$H[г6HOUV[cdfҴ#&25<ҵ<Ҷ <ҷ+-<[]y{̽ hqKhr] hr] hr] hqKhr] 0J9>*B*ph hhohj.h]U0J/5hj.h]U0J05hj.h]U5hj.ho5 ho5hoE -]{׸#8ٹNкl*r׼)@& gdPgdr] gdr] gdr] )gdr] иո׸ "#8<IQ[ιٹ39<NκкýòòòêhPh]U0J/5hPh]U0J05hPh]U5hPho5 ho5 ho0J/ ho0J0ho hqKhKhKhK5hKhr] hqKhr] hqKhr] 0J9>*B*phh]U0J9>*B*ph86lĻλ߻!#'(*9FI`cors׼ $ABNrsӯh\dhPh\d0J/5hPh\d0J05hPh\d5hPh]U0J/5hPh]U0J05hPh]U5hPho5 ho0J/ ho0J0 h]U0J/ h]U0J0h]U ho5ho;׼N CBm,LAq=z@& gdPgdr] gdr] gdr] )gdr] ) $rs$Crsz$BPrs!$0prsv{$mrs$,rsÿ h5hKhKhK5hKhr] h\d0J9>*B*ph h5hr] hr] hr] h5hr] 0J9>*B*ph h "ho ho5hoC$'Lrs$3>AZ`afklnoqr*014:;=BZ[flmqwxzhPh\d0J/5hPh\d0J05hPh\d5hPho5 ho5ho ho0J/ ho0J0Nzu| #:XU~3v7N@& gdPgdr] gdr] gdr] )gdr] )<HILcfruHI|HI !#+,3489:;HIUWXHIÿ ho0J/ ho0J0 hhKhKhK5hKhr] h\d0J9>*B*ph hhr] hr] hr] hhr] 0J9>*B*ph h0qho ho5ho@IU~HI!"367TZ[^cdv01701Nz01BPƼƼh-hr] 0J9>*B*ph hk ho ho5hPh\d0J/5hPh\d0J05hPh\d5hPhJE0J/5hPhJE0J05hPhJE5hPho5ho?B(3Vm3sV@ )gdr] gdr] gdr] )gdr] P&(013TVkmuv}~013shPhJE0J05hPhJE5hPho5 ho0J/ ho0J0ho h-hKhKhK5hKhr] hJE0J9>*B*ph h-hr] h-hr] 0J9>*B*ph hr] hr] 7*+Vx~$%@$% $%578˼ ho0J/ ho0J0 h5IrhKhKhK5hKhr] h5Irhr] hr] hr] h5Irhr] 0J9>*B*ph h!Tho ho5hPhJE0J05hPhJE5hPho5hohPhJE0J/56 8,hC|.Gm)@& gdPgdr] $%,Zeh"(),12C[abejk|D .? ho0J/ ho0J0hPhJE0J/5hPhJE0J05hPhJE5hPho5 ho5hoN?DLd)2:DG%(),16<?@CDHMSVWZjkmw hJE0J/5 ho0J/5 hJE0J05 ho0J05 ho5ho ho0J/ ho0J0R %+./027<BEFIMRX[\_oprz&*+./PT $&,.CDEFGHNOQVYnoqtuvͿͻſųjh_fUh( hJEaJh_fh5*xhJEhP ho5 hJE0J/5 ho0J/5 hJE0J05 ho0J05ho ho0J/Fr/ ]x3WGG@& gdPgdr] gdr] gdT)gdP )gdTo,c')v&89< -.G]vx 3fҸ˒h5*xho hKZhKhKhK5hKhr] hKZhr] hKZhr] 0J9>*B*phh( hPh5*x hPhThT hIshThth_f0J:jh_fU hPh_fh_f718@W_fhpsxGX`bkGhjkmqu!#DGcjklmny}jh_fUh_f h_fh_fh5*xh5*x5h5*x hkh(h( ho0J/5 ho0J05ho ho0J/ ho0J0HGG$kAeUUK6)gd!Zgd5*x@& gd5*xgd5*xgd5*xgd5*x)gd5*xgdP)gd(!"#$EI` ;<`k*-A`?FN`emvüüüüüٴټٰ٪٪ٝ h5*x0J05 h5*x0J/ h5*x0J0hMhKh5*x5 hKZh5*xhKZh5*x0J9>*B*ph hPh5*xh5*x hIsh5*xhWQh_f0J:jh_fU h_fh_fh_f>v~ U\fnyUvx}~ %'HKlnoqrw2356鿷ÿhWQh_f0J:jh_fUh_f h_fh_fh!Zh!Z5h!Z hkh( h5*x0J/ h5*x0J0h( h5*x0J05h5*x h5*x0J/5D6W[&+HIwx "79:?AGHLRSVW_gilmnrxy|}-=̿̿hf h(0J/hPh.$0J/ h(0J0hPh.$0J0h(h.$hKh!Z5 hKZh!ZhKZh!Z0J9>*B*ph hPh!Zh!Z hIsh!ZAx"=6LE )gds o,c'gdP)gd()gd!Zgd!Z@& gd!Zgd!Zgd!Zgd!ZgdP=V]e"13ABMS])6FNY#BKLaipry=CEĽ hE[h.$hs h!Zh!Z5 hPh2 hkh(h( h!Z0J/5 h!Z0J05 h!Z0J/ h!Z0J0h!ZHE_fj.589VW_0DEH\_*19Z_ai¼¼ h!Z0J/5 h!Z0J05 h!Z0J/ h!Z0J0hX}VhKh!Z5 hKZh!ZhKZh!Z0J9>*B*phhUA2 hPh!Zh!Z hIsh!ZC0\p pd6vgdr] gdr] gdk)gdP )gdko,c'))gd!Zgd!Z@& gd!Zgd!Zgd!Z!'1[p "-[p2>@adg3456W[d˼ó˯hk hIshkh4hWQh1v0J: h1vh1vjh1vUh1vhrWRh!LaJ h4h4 ho5h$oho h!Z0J/ h!Z0J0h!Zh!L@$%&45FGv+7=ipx '(gmŽŶ㔔 hkh!L ho0J/ ho0J0h'@ hPh'@ho hhKhKhK5hKhr] hhr] hhr] 0J9>*B*phh!L hPh'v hPhkhk hIshk:+d,EWuOfO )gds o,c'gdP)gdUA2gd$ogd$ogd$ogd$o)gd$ogdvB)gd!L@& gdPm679<=>Qcd*,CEUVWX׿⸸ hh$ohh$o0J9>*B*ph hPh$o hIsh$ohWQh1v0J:jh1vUh1v hkhUA2hUA2 h1vh1vh$oh$o5h$o hkh!Lx|~%5;<J{hUA2 hkhUA2 h$o0J/ h$o0J0hX}VhKh$o5 hh$ohh$o0J9>*B*ph hPhUA2 hPh$oh$o hIsh$oAO>  F    % 7 U i  )gds o,c'gdP)gdUA2gd$o@& gdPgd$ogd$ogd$o)gd$o   ! ' ( ) * + 3 : G H J M N        E F i o                 # % 5 6 7 8 R T U i o ~         h$o0J/ h$o0J0hX}VhKh$o5 hh$ohh$o0J9>*B*ph hPh$o hIsh$o hsohX}V hkhUA2hUA2hs h$oh$oh$o5?i   o  ] <Wh^~wgd$ogd$ogd$o)gd$o )gds o,c'gdP)gdUA2gd$o@& gd$o    ! ) I P X Y _ o u x }           ! 0 7 9 Z ] {            #'LRy  <LRUWf޵ hh$ohh$o0J9>*B*ph hIsh$o hsohX}Vhs h$oh$o5 hPh$ohUA2 hkhUA2 h$o0J/ h$o0J0h$oDfhy/6<>B^vy}-8t}~ 氰ðǰǰðhs h$oh$o5 hPh$ohUA2 hkhUA2 h$o0J/ h$o0J0hX}VhKh$o5h$ohh$o0J9>*B*ph hh$oB*uw*6<`egkl}*,./6<CX\o#&*,2IOcpq껵껵껻ꮪhf hkhf h$o0J/ h$o0J0hX}VhKh$o5 hh$ohh$o0J9>*B*ph hPh$oh$o hIsh$ohs hsohX}VC/CoI>c '8Qc.gd$ogdP)gd$o )gds o,c'gdP)gdfgd$o@& gd$ogd$ogd$o ;>abcdebc  %'68OQabcd~hX}VhKh$o5 hh$ohh$o0J9>*B*ph hPh$o hIsh$o hsohnx/ hkhfhfhs h$oh$o5h$oD.FMUu|.78<=KUloq Rn35DFRޱ hhYhhY0J9>*B*ph hIshY hsohnx/hs hYhY5hY hPhYhf hkhfh$o h$o0J/ h$o0J0C8o5F_q<NNT gdr] )gdr] )gdY@& gdYgdYgdYgdYgdP)gdY )gds o,c'gdP)gdfR]_nopqr  <RT[cn NRn *KNRn    R T j l n   ʾ htXhr] hr] hr] htXhr] 0J9>*B*ph hho ho5ho hY0J/ hY0J0hnx/hKhY5hY hhYhhY0J9>*B*ph?T l       z!!!"S"*####$$%%j&&&'')gdr] )gdr] gdr] gdr]               ! !!!!R!n!z!!!!!!!!!""" " "")","A"B"P"R"S"e"l"n"t"w"~"""""""""# #*#R#n#x#z###ϺϺϺϺϺ hf0J05 ho0J/5 ho0J05 hf5 ho5hfho htXhKhKhK5hKhr] htXhr] htXhr] 0J9>*B*phA################$ $$W$s$$$$% %%W%s%%%%%%& &&W&j&s&x&&&&&'' ''''%'''<'='>'?'W'Y'['\'s'v'ĽĶĶĶĶĶ hhKhKhK5hKhr] hhr] hLhr] hhr] 0J9>*B*ph h]1Xho ho5 hf0J05 ho0J05ho ho0J/5 hf0J/5>'''>'\'v''((M((())l**+=,,)-------.5.gdr] )gdr] )gdr] gdr] v'''''''( ((((M(W(c(r(s(((((((((((()) ))) )()+)2):)W)n)s)u)}))))))* **1*3*8*=*?*@*C*E*J*N*P*Q*T*d*e*l*x****++\+x++++,,=,\,a,x,,, hf0J/5 hf0J05 ho0J/5 ho0J05 hf5 ho5hoT,,,--)-7-\-x----------------.....5.C.K.N.\.a.j.x.... ///"/1/2/D/G/\/a/r/u/x/////////////// ho0J/5 ho0J05 hf5 ho5ho h+rhKhKhK5hKhr] h+rhr] hr] hr] h+rhr] 0J9>*B*ph hhoB5.j.. /G/u//0+1V1f12H2S22 334(474C4X4v444@& gdPgdr] gdr] )gdr] )gdr] //00-040<0?0F0N0\0x000000000011 1 11111#1$1+1V1a1f1}111222H2S2a2}22222 3 333a3}33333444&4(45474A4C4V4W4X4ĽĶĶĶĶhr] h(hr] hr] hr] h(hr] 0J9>*B*ph h+rho ho5 hf0J/5 hf0J05 ho0J05ho ho0J/5FX4Y4a4s4u4v4}444444444555/5a5r5}555555555666a6|6}6666666677757A7D7Q7T7a7s7}7777777777888&8a8}888899(9A9a9b9e9}999 : htho ho5 ho0J/ ho0J0ho h(hKhKhK5hKR44/5r556a6667T7778&88(9e9 :k::::::(;gdr] gdr] gdr] )gdr] ) ::::a:k:}:::::::::::::::::::;;;(;9;A;K;M;a;c;};;;;;;;<<K<a<p<}<<<<<<<<<<==a=}=====>>0>3>?>B>O>R>ȽȽ ho0J/ ho0J0 ho5ho h2hKhKhK5hKhr] h2hr] hr] hr] h2hr] 0J9>*B*phH(;M;c;;;K<p<<==R>>C??9@@@@@@LAqAAA B Bgdr] gdr] )gdr] )gdr] R>a>f>i>l>o>}>>>>??C?a?q?}?????@@9@G@a@}@@@@@@@@@@@@@@@AAAAA%ALA]AaAeAoAqA}AAAAAAA B BBB BEB\BaBrBuB}B˼ ho0J/ ho0J0 hs3hKhKhK5hKhr] hs3hr] hr] hr] hs3hr] 0J9>*B*ph h2ho ho5hoE BEBBB.ChCCJDD2EEEEEEEQFvFFFF^GGGHHgdr] gdr] gdr] )gdr] )}BBBBBBBBCC.CaChC{C}C~CCCCCCDDJDaDjD}DDDDDEE2E@EaE}EEEEEEEEEEEEEEEEEFFF F#F*FQFaFbFjFtFvF}FFFFFʻ ho0J/ ho0J0 hnhKhKhK5hKhr] hnhr] hr] hr] hnhr] 0J9>*B*ph h\hoho ho5EFFFFFGG^GaG}GGGGGGGGGGHHHHaH}HHHHHIIaI}IIIIIIIIIJ JJJJ!J$J'JAJaJ}JJJJ KKK*K-KaK}KKKKKLL3LHLJLaLbLdLxLzL}LLLLLLhr] hEhr] hr] hr] hEhr] 0J9>*B*ph hnho ho5hoQHHII JAJJ-KK3LJLdLzLLLLL?MM3NXNNN OOOgdr] gdr] gdr] )gdr] )LLLLLLLLMM?MaM}MMMMMMNN3NDNLNVNXNaNdNmNpNrNuN}NNNNNNNO OOOOO_OaO}OOOPPaPoP}PPPQQQ3QTQWQaQ}QQQQ R RRR]RaR» hr] hr] hrhr] hrhr] 0J9>*B*ph hEho ho0J/ ho0J0 ho5ho hEhKhKhK5hKGOO_OoPQWQQ]RsRRRRRRSTSjSSSTTTTTTUUUgdr] gdr] gdr] )gdr] )aRqRsR}RRRRRRRRRRRRRRRRSSSTSaSjS}SSSSSSSSTTTTTZTaTbTeTiT}TTTTTTTTTTTTTTTTUUaU}UUUUUUVV5VaV}VVVVWϾϾϾϾϾϾϾ ho5 ho0J/ ho0J0ho hrhKhKhK5hKhr] hrhr] hrhr] 0J9>*B*phKU5VVWWtXXXX Y+YFYtYYYZ ZXZZZ'[a[[b\\U]gdr] gdr] gdr] )gdr] )WWaW}WWWWWWWXXaXtX}XXXXXXXXX Y Y YYYY(Y*Y+YFYaYtY}YYYYYZZZZZZ ZXZaZ}ZZZZZ[['[a[t[w[z[}[[[[\\a\b\}\˼ ho0J/ ho0J0 h>h@th@th@t5h@thr] hr] hr] h>hr] h>hr] 0J9>*B*ph hrho ho5hoE}\\\\\\]]U]a]c]}]]]]]]^^Z^a^}^^^^^^^^^^^^__"_)_9_J_a_}______```a`i`}````aaaa}aaaaaabbRb`bab}bbh{Uhr] 0J9>*B*ph hQ)ho ho0J/ ho0J0 hQ)hr] hr] hr] hQ)hr] 0J9>*B*ph h>ho ho5hoFU]]]Z^^^^^)___i``aaaRbbbbc-cQccc dPdgd)gdr] )gdr] gdr] bbbbbbbbbbcc-cQcXcacdclc}ccccccccc dddPdad}dddddeeae}eeeeeeefffff$f+f3f5fIfafdf}ffffffgg-gag}gggghhhϾϾϾϾ ho5 ho0J/ ho0J0ho h{Uhhh5hhr] h{Uhr] h{Uhr] 0J9>*B*phKPdddaeeef5fIfdffff-gg,hQhmhhhhiijJjjjjj)h)h,hQhahmhshzh}hhhhhhhhhhiiiai}iiiiijjjjJj[jajcjnj}jjjjjjjjjjjjj kkkak}kkkkkkkkkkllllll$l%l(l.l6l7l8l;l h%<h^h%H*h% hf<aJ hf< h~<hd ho0J/ ho0J0ho ho5Lj kkkdlmmmmmmmn>n]nnnGo}oo8pppp'q@& gdPgdr] gdr]  & FgdD)gdP);lnDnOn[n]njnnnnnnָhV8hd hPhoho hchhh5hhr] hchr] hchr] 0J9>*B*phhPh~H* hPh~ hPhD hf<hmhD< h~<hnx/ hsohnx/ hnx/<4nnnnnnnnnnnnnnnnnnnnnnnnooooooooo)o,o6o9oEoFoGoNoYoZo\ocoionotowo{o|o}oo־ݲݝݮho h(=0J/hPhf0J/ h(=0J0hPhV80J0h^h~5h~hdhPh5hhPhV80J/5hPhV80J05 hV8hV8hV8hPh~0J/5hPhd0J05hPh~0J054oooop8pCp_pappppppppppppppq'qCqLqSqZq_qbqeqlqtqqqqqqrCr_rgrrrrrrrrrrrs s8sCs]s_scsjsrssssssstCt_t}tttttttuCu_uku h'ho ho0J/5 ho0J05 ho0J/ ho0J0 ho5hoP'qLqqqgrrr s8s]ssss}ttkuuuu v*v?vlvzvv@& gdPgdr] gdr] gdr] )gdr] )kuyuuuuuuuuuv v v v v'v)v*v?vCvPvXv_vbvkvlvzvvvvvvvvvvvwwCw_wzwwwwx.xCxVx_xwxzxxxxyy,yCy_yyyy¼¼¼ȵhDHGhr] 0J9>*B*phh\mho5 h\mho ho0J/ ho0J0ho h|fhhh5hhr] h|fhr] hr] hr] h|fhr] 0J9>*B*ph=vwzw.xzxyyyyyz)zNzgz{L{{K|h||||=}}A~\~@& gdPgdgdr] gdr] )gdr] )yyyyyyyyyyyyyzzzzz(z)zCzNz_zgzzzz{{({C{I{L{_{{{{{{|C|K|_|f|g|h|i|||||||||||||Ʒ hejh hejhr] hejhr] 0J9>*B*ph hr] hr] h\|hr] 0J9>*B*ph hDHGho ho5 ho0J/ ho0J0ho hDHGhhh5hhr] hDHGhr] :||}} }=}C}_}}}}}~A~C~\~_~m~q~t~w~z~~~~~~~~~~~~~~~~C_z(*CHJ_ce|}~Ԁ h\5hhh5hhr] h\5hr] hr] hr] h\5hr] 0J9>*B*ph h])Cho ho0J/5 ho0J05ho ho5D\~~~~z*Je~e.rĄ)gdgdr] gdr] gdr] )gdr] 9ACLOW_beuzρԁ؁C_Â΂тԂق.>CGO_rԃC_ĄԄC_ԅCGH_ȹh!phr] 0J9>*B*ph%jh!phr] 0J9>*B*Uph h\5ho ho0J/ ho0J0 ho0J/5 ho0J05hoIG/vƇ2G~ 6`ŠˊЊ!-)@& gdPgdr] gdr] gdr] )gdr] Ԇ#$%,-/0C_nopstvwÇćƇLJԇǪǔ~h+jh!phr] 0J9>*B*Uph+jh!phr] 0J9>*B*Uph+jh!phr] 0J9>*B*Uph+jh!phr] 0J9>*B*Uph h!phr] h!phr] 0J9>*B*ph%jh!phr] 0J9>*B*Uph+jh!phr] 0J9>*B*Uph(/12CGX_`k}~ƈψӈԈ݈ 6C_ԉC_`nŠɊˊΊЊԊ!+,-ľľľʷ hn{bhr] hr] hr] hn{bhr] 0J9>*B*ph h rho ho0J/ ho0J0ho h!ph'Xh'Xh'X5h'Xhr] h!phr] %jh!phr] 0J9>*B*Uph<-.CHJK_`ruzɋҋ1?AZ]_gɌAI]eɍ A]knp¼¼¼¼鵵 h3hr] hr] hr] h3hr] 0J9>*B*ph hn{bho ho0J/ ho0J0 ho5 h(=0J/5 ho0J/5 h(=0J05 ho0J05ho hn{bh'Xh'Xh'X5h'X<-K`ҋ1?Ie kpŎڎ\ɏgdr] gdr] )gdr] )@& gdvBgdr] ŽĎŎɎڎA\]mt}ɏA]ƐɐA]ɑA]ɒAW]ɓϓ*A]mɔϾϾ ho5 ho0J/ ho0J0ho h3h'Xh'Xh'X5h'Xhr] h3hr] 0J9>*B*ph h3hr] KƐW*Hʖ˜&Gޛ&5ÞKW")A]ɕAH]ɖʖAZ]gjɗA]˜ɘ&A]~əAG]fgou{|$*-.014DE h(=0J/5 ho0J/5 h(=0J05 ho0J05 ho0J/ ho0J0 ho5hoREYޛ&;W5;WexA]ÞA]AKW]"A]nޡ&@\&@\^xۣh(= ho5 h(=0J/5 ho0J/5 h(=0J05 ho0J05hoU"nޡ&&^xۣ :` =i F`)ۣ :@\` =@\i @F\`@\$@Q\svШӨ֨٨ @\m @\v+@\h*7[jh*7[U ho5ho]$Qm v+׫  0$If$a$gdtt2$a$gdD7')Ыѫ֫׫    /069:@ACDEFGHI꼳hohUA2mHnHujhUA2U hUA20J- hUA20J. h&#hUA2 h+mhUA2 hUA20J, hUA20J+hUA2 hUA20J*jh*7[Uh*7[&0EFGHI'Lkd$$IfA0$P44 Aa1$If/<0BP/ =!"#$% DyK yK lhttp://www.specagent.com/Lookup?ulid=2066yX;H,]ą'cDyK yK zhttp://www.specagent.com/Lookup?uid=123457113832yX;H,]ą'cDyK yK zhttp://www.specagent.com/Lookup?uid=123457113828yX;H,]ą'cDyK yK zhttp://www.specagent.com/Lookup?uid=123457113831yX;H,]ą'cDyK yK zhttp://www.specagent.com/Lookup?uid=123457113827yX;H,]ą'cH$$If!vh#v#vP:V A55P4 AHy666666666vvvvvvvvv666666>6666666666666666666666666666666666666666666666666hH6666666666666666666666666666666666666666666666666666666666666666662 0@P`p2( 0@P`p 0@P`p 0@P`p 0@P`p 0@P`p 0@P`p8XV~ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@666666_HmH nH sH tH <`< NormalCJ_HmH sH tH DA`D Default Paragraph FontRi@R 0 Table Normal4 l4a (k ( 0No List 4O4 HDR$*$a$0O0 FTR$*$a$,O", SCT *$a$<OR< PRT$$ & F*$@&a$:b: SUT$ & F*$@&a$:b: DST$ & F*$@&a$DObD ART$$$ & F `*$@&a$BObB FPR1!$ & F `*$@&a$>Or> PR2$ & F *$@&a$>O> PR3$ & F *$@&a$>> PR4$ & F  *$@&a$>> PR5$ & F ` *$@&a$0b0 TB1*$^ a$0r0 TB2*$^`a$00 TB3*$^a$00 TB4*$^a$00 TB5*$^ a$00 TF1 *$^ a$00 TF2!*$^`a$00 TF3"*$^a$00 TF4#*$^a$00 TF5$*$^ a$&R& TCH%*$.b. TCE &*$^`p,Or, EOS '*$a$<< ANT (*$a$<>*B* ph6O6 7CMT )*$a$ B*phO CPRO SPNO SPDO NUMO NAM&o& SI B* ph&o& IP B*ph*O* RJUST1a$4@"4 3o 0Header 2H$.1. 2o 0 Header Char4 B4 5o 0Footer 4H$.Q. 4o 0 Footer Char\Ob\ 8TIP26NOPQ B* ph86/q6 )CMT Char B*CJph4/4 6TIP Char <B* ph8:o: [ SAhyperlink >*B*phl 6U`6 [0 Hyperlink >*B*phHH <D70 Balloon Text;CJOJQJ^JaJNoN ;D70Balloon Text CharCJOJQJ^JaJO D7PM_CMTd=$$d!%d$&d!'d$*$-DM N!O$P!Q$a$ B*aJphB' B |RT0Comment ReferenceCJaJ88 @|RT0 Comment Text?CJ:: ?|RT0Comment Text Char@j@ B|RT0Comment SubjectA5\F/!F A|RT0Comment Subject Char5\@ 2@|RT0RevisionCCJ_HmH sH tH Rv!AR r] 0Unresolved MentionB*phq xRx G2PRNWE$d!%d$&d!'d$-DM N!O$P!Q$,/a, 2PR1 CharCJ>/q> E2PRN CharCJfHq PK![Content_Types].xmlN0EH-J@%ǎǢ|ș$زULTB l,3;rØJB+$G]7O٭VGRU1a$N% ʣꂣKЛjVkUDRKQj/dR*SxMPsʧJ5$4vq^WCʽ D{>̳`3REB=꽻Ut Qy@֐\.X7<:+& 0h @>nƭBVqu ѡ{5kP?O&Cנ Aw0kPo۵(h[5($=CVs]mY2zw`nKDC]j%KXK 'P@$I=Y%C%gx'$!V(ekڤք'Qt!x7xbJ7 o߼W_y|nʒ;Fido/_1z/L?>o_;9:33`=—S,FĔ觑@)R8elmEv|!ո/,Ә%qh|'1:`ij.̳u'k CZ^WcK0'E8S߱sˮdΙ`K}A"NșM1I/AeހQתGF@A~eh-QR9C 5 ~d"9 0exp<^!͸~J7䒜t L䈝c\)Ic8E&]Sf~@Aw?'r3Ȱ&2@7k}̬naWJ}N1XGVh`L%Z`=`VKb*X=z%"sI<&n| .qc:?7/N<Z*`]u-]e|aѸ¾|mH{m3CԚ .ÕnAr)[;-ݑ$$`:Ʊ>NVl%kv:Ns _OuCX=mO4m's߸d|0n;pt2e}:zOrgI( 'B='8\L`"Ǚ 4F+8JI$rՑVLvVxNN";fVYx-,JfV<+k>hP!aLfh:HHX WQXt,:JU{,Z BpB)sֻڙӇiE4(=U\.O. +x"aMB[F7x"ytѫиK-zz>F>75eo5C9Z%c7ܼ%6M2ˊ 9B" N "1(IzZ~>Yr]H+9pd\4n(Kg\V$=]B,lוDA=eX)Ly5ot e㈮bW3gp : j$/g*QjZTa!e9#i5*j5ö fE`514g{7vnO(^ ,j~V9;kvv"adV݊oTAn7jah+y^@ARhW.GMuO "/e5[s󿬅`Z'WfPt~f}kA'0z|>ܙ|Uw{@՘tAm'`4T֠2j ۣhvWwA9 ZNU+Awvhv36V`^PK! ѐ'theme/theme/_rels/themeManager.xml.relsM 0wooӺ&݈Э5 6?$Q ,.aic21h:qm@RN;d`o7gK(M&$R(.1r'JЊT8V"AȻHu}|$b{P8g/]QAsم(#L[PK-![Content_Types].xmlPK-!֧6 0_rels/.relsPK-!kytheme/theme/themeManager.xmlPK-!g theme/theme/theme1.xmlPK-! ѐ' theme/theme/_rels/themeManager.xml.relsPK] I$ ss  "1'(b,15v8;;@AFIK/OS UZK\pafim&qvwy};U2Hym"IP?vv6=EmX fR #v',/X4 :R>}BFLaRW}\bh;lnokuy|-EۣI    "#%&')*,-.0134678:<=>@ACEFHIKLNPRSUWYZ\^`abdfgiklmoqrtvh $+2 8C@4HO}Ve^3fVmvj}}ːSm׼z GOi T '5.4(; BHOOUU]Pdj'qv\~-"0I  !$(+/259;?BDGJMOQTVX[]_cehjnpsuww4Xg> a o u!23=G~~~~$,/osvIXXXXXXXXXXXXXX!T # @H 0(  0(  B S  ?; _Hlk13481176 _Hlk514844288ptBookmark2001ptBookmark2002ptBookmark2003ptBookmark2004ptBookmark2006ptBookmark2007ptBookmark2009ptBookmark2010ptBookmark2011ptBookmark2012ptBookmark2014ptBookmark2015ptBookmark2016ptBookmark2017ptBookmark2018ptBookmark2020ptBookmark2021ptBookmark13376ptBookmark2022ptBookmark2024ptBookmark2025ptBookmark2027ptBookmark2028ptBookmark2029ptBookmark2030ptBookmark2031ptBookmark2032 _Hlk523840239 _Hlk523844008ptBookmark2033 _Hlk523839961 _Hlk2548950 _Hlk523840376 _Hlk523844133ptBookmark2035ptBookmark13373ptBookmark13374ptBookmark13375ptBookmark13377ptBookmark2038ptBookmark2039ptBookmark2040ptBookmark3261ptBookmark2043ptBookmark2045ptBookmark2046ptBookmark2048ptBookmark2049 _Hlk511638026 _Hlk514846767ptBookmark2051ptBookmark2052ptBookmark2053ptBookmark2065ptBookmark2066ptBookmark5553ptBookmark5554  e#&*.+7>gB/GBKRbYu]`eunϜVBB GLGj)%+ 2982=CItPUURZcdTekmqszwG~` J " !#$%&'()*+,-./0312456789: #B'+/8w?CGLUSY2^afowǤ˪Ѹ9uMUE=%W,28=DJ QUZdqee nqgt}x,J L0P0000161:1o1s18899P9S99999LL)M,M^MaMMMSSmTpTTTTT9br!14mq>EelU[ip59pv ?CFL"){  g k w } \cddvzGJbbNu]u@}L}̓ك̆؆pv*3_dDK\ c   '"'Z'a'--//EEHO)/ȋϋfmGJ3333333333333333333333333333 vv=BBs s   e"e"2'2'''$)$)ccDfDf[f[fEExx֣ 9DJ vv=BBs s   e"e"2'2'''$)$)ccDfDf[f[fEExx֣ 9DJĠ PART -  SCHEDULE  - PRODUCT DATA SHEET  - ``^``.``^``.^`.^`.  ^ `)` ` ^` `)             eP p'RWЎ\R:US*pB*P p'RWЎ\*8\_*UV,RoSs  *f&RPS*pW-|i.9[<QemSfTuU'Va.P p'RW?k3dfo er] ~ ]KZ\ "|f)y02^Y hto% &?)Q)*+&+'4,I.j.f/nx/-0Sn0..1V%2UA2gR3im34$@4\5r626D7W7V%8<8'@4A])CJEDHG^ZHNKqKLaL!LXNLNOP|rQoeRmST T!T|RT`UQ'U]UX}V]1XBY!ZFbZ*7[\R\j]n{b\deVle_f,jejmS2mn$o!p=p_pwp~q0q r+r?r5Ir.&setqu1v@Bv5*xg {\|8U~vn'v_f`ln+ez`tt2{U[>h06{o(V8>,3n< vBQ5iB'X~"Ed J%&DxDOIFormatMF04MF95MFOrigin SectionIDSpecTypeVersion09/01/17122111915145MF04458 MasterSpec13860@I @UnknownEdited by AVITRU for OateyG.[x Times New Roman5Symbol3. .[x Arial9. . Segoe UIC.,.{$ Calibri Light7..{$ CalibriA$BCambria Math"qhhxx<f4Cy<f4Cy!2XXKqHX  $Po  !xxǨz 2SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES!DOMESTIC WATER PIPING SPECIALTIESBAS-12345-MS80 AVITRU, LLC.Edited by AVITRU for Oatey Oh+'0(8 \h   4SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES$DOMESTIC WATER PIPING SPECIALTIESAVITRU, LLC.BAS-12345-MS80NormalEdited by AVITRU for Oatey3Microsoft Office Word@G@a2`@822`4<f ՜.+,D՜.+,|8 px  AVITRU, LLC.xyCX 3SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES Title\ 8@ _PID_HLINKSATFQ'1http://www.specagent.com/Lookup?uid=123457113827GW$1http://www.specagent.com/Lookup?uid=123457113831F^!1http://www.specagent.com/Lookup?uid=123457113828GT1http://www.specagent.com/Lookup?uid=123457113832A*http://www.specagent.com/Lookup?ulid=2066j~?http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/Metal20IMB2.pdf]R=http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/fire-imob.pdfYHhttp://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/Metal_WMOB_Submittal.pdfC_=http://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/FIRE WMOB.pdf/, Lhttp://www.oatey.com/ASSETS/DOCUMENTS/ITEMS/EN/centro-wmob-ii-submittal.pdfG http://www.oatey.com/)?http://www.avitru.com/Jhmailto:info@oatey.comGhttp://www.oatey.com/  !"#$%&'()*+,-./0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^_`abcdefghijklmnopqrstuvwxyz{|}~      !"#$%&'()*+,-./0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^_`abcdefghijklmnopqrstuvwxz{|}~Root Entry F.2`Data y1Table6NWordDocument1SummaryInformation(DocumentSummaryInformation8CompObjr  F Microsoft Word 97-2003 Document MSWordDocWord.Document.89q