480 to 120v control transformer
[DOC File]SECTION 1 – GENERAL
https://info.5y1.org/480-to-120v-control-transformer_1_eb2048.html
The meter shall communicate over the electrical power wiring to a Scan Transponder via bi-directional, frequency-hopping, spread-spectrum power line communications. These signals shall be capable of passing through a single 600:120V or 480:120V transformer.
SECTION 261116 - SECONDARY UNIT SUBSTATIONS
The control power transformer shall be 480-240/120V, single phase, 60 hertz, VA rating as required by the load (15kVA, Single Phase minimum), with primary and secondary fuses. The panelboard shall comply with the requirement of Division 26 Section "Panelboards" and be provided with a main circuit breaker and as a minimum, branch circuit breaker ...
[DOC File]METRON, INC
https://info.5y1.org/480-to-120v-control-transformer_1_97edf0.html
Qty (1) Control Power Transformer, 480-120V Pri/Sec fused (1) lot section heaters with thermostat. Qty (1) Copper Ground Bar with (2) lugs. ITEM #2: Main MAIN-MSG Switchboard: Electrical Rating: - 1200A, 480/277VAC, 3phs, 4wire, 22Kaic - Service Entrance Label - 1200Amp Plated Copper Main Bus. General Enclosure Information All Sections Combined:
[DOC File]TECHNICAL SPECIFICATION
https://info.5y1.org/480-to-120v-control-transformer_1_8cada6.html
Fan motor operates at 480-3-60. Control circuits at 120V-1-60. Control circuits fused. Control circuit fuses are 200,000 A.I.C. current limiting type, 600V rated. General Description: The load bank is a completely self-contained, freestanding, skidded unit consisting of three (3) principle sections: 1. Environmentally controlled transformer ...
[DOCX File]Low Voltage Switchgear - library.e.abb.com
https://info.5y1.org/480-to-120v-control-transformer_1_c44f65.html
The unit shall be provided with a 120V control power transformer. All remote control wiring shall be in the 120V circuit. The control power transformer shall be provided with primary and secondary fusing. Provide a door mounted human interface module for programming, control and display.
[DOC File]METRON, INC
https://info.5y1.org/480-to-120v-control-transformer_1_542baf.html
Qty (3) Potential Transformer, 480-120V Pri/Sec fused. Qty (1) Control Power Transformer, 480-120V Pri/Sec fused. Qty (1) Power Quality Meter. Qty (1) Vestibule fluorescent light and hardware (1) lot section heaters with thermostat and humidistat. Qty (1) Copper Ground Bar with (2) lugs
[DOC File]SIMPLEX, INC
https://info.5y1.org/480-to-120v-control-transformer_1_0b9364.html
9. Control Power: Internal, from generator. 480V AC, single-phase. Fused circuits. Controls operate at 120V via control power transformer circuit. Principle systems and components as follows: 1. Load Elements: Tubular type, weatherproof, totally enclosed, UL listed. 2. Load Control: Branch circuit magnetic contactors. 3. Element Short
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Hot searches
- facebook facebook twitter facebook twitter twitter facebook
- ach payment request form
- map of texas cities and towns
- major depressive disorder icd 10
- generally accepted auditing standards
- what to expect when inducing labor
- types of sensory nerves
- principles of marketing notes
- sample memo to staff employees
- nycha housing developments list