Portable 480 volt generator

    • [PDF File]Amp chart - Cummins Inc.

      https://info.5y1.org/portable-480-volt-generator_1_8294f7.html

      Generator rating: kVA kW @0.8 PF 120 Volts 208 Volts 220 Volts 240 Volts 440 Volts 480 Volts 600 Volts 2400 Volts 3300 Volts 4160 Volts 6900 Volts 11,500 Volts 13,800 Volts Alternator amperes (for 3-phase alternators): 18.7 15 90 52 49 45 25 23 18 - - - - - - 25 20 120 69 66 60 33 30 24 6 4 3 - - - 31.3 25 151 87 82 75 41 38 8 5 4 2 1.5 1 -


    • STANDBY 350 ekW 438 kVA

      60 Hz 1800 rpm 480 Volts TECHNICAL DATA Open Generator Set - - 1800 rpm/60 Hz/480 Volts DM8149 EPA Certified for Stationary Emergency Application (EPA Tier 3 emissions levels) Generator Set Package Performance Genset power rating @ 0.8 pf Genset power rating with fan 437.5 kVA 350 ekW Fuel Consumption 100% load with fan 75% load with fan 50% ...


    • [PDF File]Using OutBack Inverters for 3-Phase 480V Applications

      https://info.5y1.org/portable-480-volt-generator_1_63266a.html

      generator, a battery, a photovoltaic array and an inverter system equipped with remote control and monitoring systems. This design makes the system portable and rugged, while allowing multiple systems to be stacked to achieve higher generation and storage capacities, as well as to increase reliability through redundancy.


    • [PDF File]Portable Generator One Box (PGOB)

      https://info.5y1.org/portable-480-volt-generator_1_636baa.html

      Generator Connection • Prevents Paralleling Permanent and Portable Generators • 200—4,000 Ampere Ratings Available (4000A—Not UL Listed) • 120/240 Volt, 120/208 Volt, or 277/480 Volt Ratings Available The Portable Generator One Box is a product that assists in the connection of your Portable Generator to your building.


    • Generator Quick-Connect Double-Throw Safety Switch

      MAXIMUM GENERATOR CURRENT OUTPUT AND SWITCH SIZING CHART Three-Phase Single-Phase (80% Power Factor) (Unity Power Factor) 208 Volt 480 Volt 240 Volt Non- Non- Non- kW Amps Fusible Fusible 22 2 5 17 30 30 830 3021 30 30 7.5 26 60 30 11 30 30 31 60 60 10 35 60 60 15 30 30 42 60 60 12 42 60 60 18 30 30 50 100 60 15 52 100 60 23 30 30 63 100 100


    • [PDF File]MOBILE DIESEL GENERATORS

      https://info.5y1.org/portable-480-volt-generator_1_cb7e99.html

      generator models offer an extra 600-volt selection for maximum versatility. KEY FEATURES • Integrated transformer for ease of use • Easy-to-switch voltage selection ... Amps (480/208 V) N/A N/A N/A 37 / 86 47 / 108 60 / 139 72 / 167 102.36 / 236.22 127.95 / 295.27


    • [PDF File]Portable Generator Connection Box (PGCB)

      https://info.5y1.org/portable-480-volt-generator_1_aead4c.html

      • Permanent or Portable Generator Connection • Simple and Clean Generator Connection • Multiple Cable Connection Methods • Pad Mounted • 100A-4000 Ampere ratings available • 120/240 Volt, 120/208 Volt, or 277/480 Volt Ratings Available The Portable Generator Connection Box (PGCB) is a product that assists in the connection of


    • [PDF File]MQ POWER Series Generator

      https://info.5y1.org/portable-480-volt-generator_1_875764.html

      1Ø 120 Volt 55.6 Amps (4 wire) 1Ø 240 Volt 27.8 Amps (4 wire) 3Ø 240 Volt 60 Amps 3Ø 480 Volt 30 Amps Main Line Circuit Breaker Rating 60 Amps Over Current Relay Trip Set Point 30 Amps NOTICE Generator is not intended for use in enclosed areas or where free flow of air is restricted. Backfeed to a utility system can cause electrocution ...


    • [PDF File]MQ POWER Series Generator

      https://info.5y1.org/portable-480-volt-generator_1_48f5e4.html

      1Ø 240 Volt 50 Amps (4 wire),108A (Zigzag 3Ø 240 Volt 108 Amps 3Ø 480 Volt 54 Amps Main Line Circuit Breaker Rating 125 Amps Over Current Relay Trip Set Point 480V Mode Only 54 Amps WARRANTY* Isuzu Engine** 12 months from date of purchase with unlimited hours or 36 months from date of purchase with 3,000 hours (whichever comes first). Generator


    • [PDF File]Sizing a Generator for a Specific Electric Motor Load, or ...

      https://info.5y1.org/portable-480-volt-generator_1_aaf91f.html

      7.425x4.167 = 30.9 = 31 LRA. The generator must produce 31 Amps at 240 Volts, to safely start this motor. Multiply 31 amps x 240 Volts = 7400 Watts or 7.5 KW generator size. Sizing a generator for three phase motor starting LRA : The formula is: Motor HP x KVA per HP x (1000 / (Volts x 1.73)) = LRA. Example: A 20 HP Code G motor connected to 460



    • [PDF File]Sizing gensets for motor starting - Kohler Power

      https://info.5y1.org/portable-480-volt-generator_1_5c27ef.html

      more expensive generator or too small a generator than is necessary for KohlerPower.com ©2009 by Kohler Co. Sizing gensets for motor starting A practical guide to understanding how motor-starting loads affect genset performance POWER SYSTEMS TOPiCS 103 By: dan Krueger Senior Field Applications Engineer Kohler Power Systems-Americas rick Van maaren


    • [PDF File]Dimensions MAGNAPOWER - Marathon Generators

      https://info.5y1.org/portable-480-volt-generator_1_e85134.html

      Generator Design Specifications: • High grade Class F insulation system for 6600–13,800 V • High grade Class H insulation system for 480–4160 V • Vibration limits to NEMA MG-1 • 300%–60 Hz (250%–50 Hz) short circuit current for 10 seconds • Harmonic content less than 5% kW ® kVA ® ® ® ® ®


    • [PDF File]kVa & kW Amperage Chart - Generator Source

      https://info.5y1.org/portable-480-volt-generator_1_fcfd55.html

      This chart estimates the output amperage of a generator based on the operating power and voltage. Please note that this table is intended to be used as an estimate of how many amps a generator outputs during operation and is not an exact representation due to various factors that can increase or decrease this value.


    • [PDF File]Catalog Pages: Appleton™ Powertite™ Series Pin and Sleeve ...

      https://info.5y1.org/portable-480-volt-generator_1_a2c08b.html

      • Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, SCR/VFD houses, and ... Motor Phase Amps 240 Vac 480 Vac 600 Vac Motor Phase Amps 115 Vac 240 Vac 480 Vac 600 Vac


    • [PDF File]Generator sizing guide

      https://info.5y1.org/portable-480-volt-generator_1_90bf98.html

      Generator sizing guide EATON www.eaton.com Table 1. Motor load reference ac and heat pumps Running load Starting load Description hp Running kW Single-phase Three-phase Single-phase Three-phase kW Amps at 240 V Amps at 208 V Amps at 240 V Amps at 480 V LR amps at 240 V LR amps at 208 V LR amps at 240 V LR amps at 480 V 1 ton (12,000 BTU) 1 1 5 ...


    • WHITE PAPER - Power Equipment and Generator Manufacturer

      For 480 volt equipment, these limits are converging at 8,000 kW. This tends to be the strong transition point to move to medium voltage or split the low voltage generator bus into two separate systems. Physical Location When an application has loads that are physically located far apart, the cost of the low voltage cabling becomes a significant


    • [PDF File]Grounding Requirements for Portable Generators

      https://info.5y1.org/portable-480-volt-generator_1_b798f2.html

      tor) are bonded to the generator frame, § 1926.404(f)(3)(i)(B). Thus, rather than connect to a grounding electrode system, such as a driven ground rod, the generator’s frame replaces the grounding electrode. If these conditions do not exist, then a grounding electrode, such as a ground rod, is required. If the portable generator is providing ...


    • [PDF File]Electrical Code Rules for Portable & Temporary Electrical ...

      https://info.5y1.org/portable-480-volt-generator_1_e9f005.html

      All 125-volt and 125/250- volt, single-phase, 15- and 20-ampere receptacle outlets that are part of a 15kW or smaller portable generator must have listed ground-fault circuit-interrupter protection for personnel.


    • [PDF File]Portable Generator Hazards

      https://info.5y1.org/portable-480-volt-generator_1_04b561.html

      Portable generators are useful when temporary or remote electric power is needed, but they also can be hazardous. The primary hazards to avoid when using a generator are carbon monoxide (CO) poisoning from the toxic engine exhaust, electric shock or electrocution, fire and burns. Every year, people die in incidents related to portable generator ...


Nearby & related entries: