    • Does EWC control include a hand damper?

      EWC Controls includes the SAS (Supply Air Sensor) with every Ultra-Zone control panel. The use of a Hand Damper is recommended to be installed in the ByPass Return Run. If the bypass is used, it would be sized to handle the excess pressure build up under the worst case scenario rule.


    • Do air zoned systems need a balancing hand damper?

      Balance the System. All HVAC systems needs to be balanced and an air zoned system is no exception. Use the zone damper itself to restrict or allow more flow to a particular zone and/or install balancing hand dampers in the branch runs.


    • Does EWC control include a supply air sensor?

      EWC Controls includes the Supply Air Sensor (Part# SAS)with every micro-processor based Ultra-Zone control panel. Whether the bypass tool is used exclusively or along with other air management tools, the bypass duct should be sized to manage the airflow and volume under the worst case scenario, less any open run Cfm and damper leakage Cfm.


    • When did EWC controls introduce the communicating zone panel?

      In 2011, EWC Controls introduced the first Communicating Zone panel built on the ClimateTalk open protocol. This industry setting, cutting edge product is well advanced of any current product offering. Once again, as recognized by our peers, EWC Controls was awarded the Dealer Design Award for this advancement in technology.


    • [PDF File]Model UZC4 Zone Control - EWC

      https://info.5y1.org/ewc-zone-damper-system_1_4dcfaa.html

      Damper 1 thru Damper 20 green LEDs will indicate which zone dampers are demanded to energize Open or Closed. All modules operate on 24vac power supplied from a separate transformer. A single 40va transformer can power up to 4 zones, with a total of 8 Genuine EWC ND or URD dampers directly connected. See pages 19 for details.


    • [PDF File]Forced Air Zone Controls - EWC

      https://info.5y1.org/ewc-zone-damper-system_1_4c7261.html

      How the ULTRA-ZONE System works. The purpose of the Ultra-Zone system is to provide total comfort in the home and office. Motorized dampers are “opened” or “closed” by thermostats based on the temperature set point of the homeowner. The damper system will control the airflow through the ductwork and deliver ONLY the desired air to the ...


    • [PDF File]TM SUBMITTAL SHEET SBD2 Forced Air Zone Controls

      https://info.5y1.org/ewc-zone-damper-system_1_8aee06.html

      The Ultra-Zone Smart Bypass Damper captures (with the push of a button) the total static pressure of the HVAC system during non-zoned mode, and modulates to maintain that same static pressure value, during zoned mode. As individual zone dampers open or close, the HVAC system static pressure will fluctuate.


    • [PDF File]EcoNet Zoning Panel by EWC Controls Inc. - Baker Dist

      https://info.5y1.org/ewc-zone-damper-system_1_7ae10c.html

      After assigning the zone numbers to each zone control, go to the EcoNet Smart Thermostat, zone 1 control, and tap Menu > Status > Zoning. All discovered zones will be listed along with the respective set point, zone temperature, humidity, damper position, and airflow.


    • [PDF File]Model NCM300 Zone Control System - EWC

      https://info.5y1.org/ewc-zone-damper-system_1_ea83cb.html

      practically any off-the-shelf thermostat. With features like Automatic changeover, Timed or Thermostatic staging, Field selectable Features and built-in Supply air Sensing, the NCM300 provides the highest level of performance and versatility in a non-expandable zone control panel. Perfect for new construction and most retro-fit applications.


    • [PDF File]090375A0260 Q - EWC

      https://info.5y1.org/ewc-zone-damper-system_1_25de32.html

      The patented UT3000 Zone Control System has been enhanced to provide intelligent zone control of the Daikin FIT ™ and ComfortNet ™ communicating HVAC systems or 24volt legacy HVAC systems. Create 2 or 3 air zones with a single panel or “twin” two UT3000’s together to create a 4 or 5 zone system.